Literature DB >> 1402585

Assessment of external root resorption using digital subtraction radiography.

L H Kravitz, D A Tyndall, C P Bagnell, S B Dove.   

Abstract

Digital subtraction radiography was investigated for its capability to detect and quantify experimentally produced external root resorptive defects in teeth. Using a long source to object X-ray technique and E-speed film, serial radiographs of teeth with artificial lesions in a dry human skull (soft tissue simulated) were obtained. Receiver operating characteristic analysis was used to evaluate the diagnostic performance for each imaging system (conventional versus subtraction). To explore the quantitative assessment potential of digital subtraction radiography, images were produced after sequential demineralization by HCl. The acid solution was analyzed for calcium concentration by atomic absorption spectrophotometry. Three-dimensional histogram quantification for each subtracted image was performed. In overall performance for detecting experimentally produced external root resorption, digital subtraction radiography was found to be significantly superior to conventional radiography. In addition, digital subtraction radiography can provide quantification of experimentally produced external root resorptive defects.

Entities:  

Mesh:

Year:  1992        PMID: 1402585     DOI: 10.1016/s0099-2399(06)80954-4

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study.

Authors:  Zahra Dalili; Mehran Taramsari; Seyed Zoheir Mousavi Mehr; Fatemeh Salamat
Journal:  Imaging Sci Dent       Date:  2012-03-22

2.  A retrospective study of digital subtraction technique to detect sclerotic changes in alveolar bone on intraoral radiographs of bisphosphonate-treated patients.

Authors:  M U Zaman; T Nakamoto; K Tanimoto
Journal:  Dentomaxillofac Radiol       Date:  2013-10-29       Impact factor: 2.419

3.  Accuracy of linear and volumetric measurements of artificial ERR cavities by using CBCT images obtained at 4 different voxel sizes and measured by using 4 different software: an ex vivo research.

Authors:  Gül Sönmez; Cemre Koç; Kıvanç Kamburoğlu
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

Review 4.  Root Resorption in Orthodontics.

Authors:  Furkan Dindaroğlu; Servet Doğan
Journal:  Turk J Orthod       Date:  2016-12-01

5.  A posteriori registration and subtraction of periapical radiographs for the evaluation of external apical root resorption after orthodontic treatment.

Authors:  Eliane Maria Kreich; Ana Cláudia Chibinski; Ulisses Coelho; Letícia Stadler Wambier; Rosário de Arruda Moura Zedebski; Mari Eli Leonelli de Moraes; Luiz Cesar de Moraes
Journal:  Imaging Sci Dent       Date:  2016-03-24

6.  Localized idiopathic root resorption in the primary dentition: Review of the literature and a case report.

Authors:  Atefeh Nasehi; Fatemeh Mazhari; Nooshin Mohtasham
Journal:  Eur J Dent       Date:  2015 Oct-Dec
  6 in total