Equilibration of air temperature inside the thimble of a Farmer-type ion chamber.

R C Tailor1, C Chu, D S Followill, W F Hanson.   

Abstract

Ionization chambers are frequently moved from one environment to another, sometimes with significant differences in temperature between the chamber and measurement phantom. To obtain reliable ionization data, the temperature of the air in the chamber must be allowed to equilibrate with the measuring phantom. The air temperature inside a thimble of a Farmer-type ion chamber was measured as a function of time for various phantom materials (air, water, and plastic). Equilibration rates for the various conditions are presented. Heat-diffusion theory is presented to explain the characteristics of the measured data. Waiting times for temperature equilibration down to 10% of the initial temperature difference ranges from 1 to 18 min, depending on the phantom material and use of bare or covered thimble. Radiation measurements confirm the temperature data.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9571617     DOI: 10.1118/1.598226

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Investigation of thermal and temporal responses of ionization chambers in radiation dosimetry.

Authors:  Hussein AlMasri; Akira Funyu; Yasumasa Kakinohana; Sadayuki Murayama
Journal:  Radiol Phys Technol       Date:  2012-04-01

2.  Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams.

Authors:  Malcolm McEwen; Larry DeWerd; Geoffrey Ibbott; David Followill; David W O Rogers; Stephen Seltzer; Jan Seuntjens
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

3.  Quantification of the temperature equilibrium time of the cavity in parallel-plate-type ionization chambers by thermal analysis.

Authors:  Hiraku Fuse; Soma Hirota; Tatsuya Fujisaki; Shinji Abe; Kenji Yasue; Koichi Hanada; Fumihiro Tomita
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

4.  Quantifying temperature-equilibrium time using temperature analysis inside a Farmer ionization chamber.

Authors:  Hiraku Fuse; Tatsuya Fujisaki; Shinji Abe; Kenji Yasue; Satoshi Oyama
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

5.  Radiation Therapy Deficiencies Identified During On-Site Dosimetry Visits by the Imaging and Radiation Oncology Core Houston Quality Assurance Center.

Authors:  Stephen F Kry; Lainy Dromgoole; Paola Alvarez; Jessica Leif; Andrea Molineu; Paige Taylor; David S Followill
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-08-24       Impact factor: 7.038

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.