Thermal and temporal response of ionization chambers in radiation dosimetry.

Indra J Das1, Timothy C Zhu.   

Abstract

The temporal and thermal response of various commonly used ion chambers (NEL, Exradin, PTW) with different wall and electrode materials is studied in a water phantom. Measurements were taken in heating water bath having an automatic temperature control mechanism. All chambers were submersed at 3 cm depth in water phantom and connected to separate electrometers for simultaneous readings for a given dose from a 6 MV beam. The temporal response was studied at approximately +/- 10 degrees C from room temperature, i.e., 10 degrees C and 30 degrees C. Temporal results show that all chambers reach quick equilibrium response within < 2 minutes of submersion in water. The steady-state thermal response was dependent upon the water temperature and wall and electrode compositions. The temperature and pressure corrected response of the NEL chamber was least affected by the changes in water temperature, where as the Exradin chamber has positive and PTW has negative slope with water temperature. The response varied within +/-1.5% between 10 degrees C-50 degrees C temperature and is mainly dependent on volume changes rather than the humidity. A correction factor based on thermal coefficients is derived for each chamber. It is concluded that ion chamber correction factors can be divided into first order; temperature and pressure connection, second order; volume correction for thermal expansion, and third order; humidity correction. To eliminate dosimetric error, the temporal and thermal response should be known for a chamber or water phantom temperature should be maintained close to room temperature.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15070256     DOI: 10.1118/1.1644520

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Investigation of thermal and temporal responses of ionization chambers in radiation dosimetry.

Authors:  Hussein AlMasri; Akira Funyu; Yasumasa Kakinohana; Sadayuki Murayama
Journal:  Radiol Phys Technol       Date:  2012-04-01

2.  Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams.

Authors:  Malcolm McEwen; Larry DeWerd; Geoffrey Ibbott; David Followill; David W O Rogers; Stephen Seltzer; Jan Seuntjens
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

3.  Quantification of the temperature equilibrium time of the cavity in parallel-plate-type ionization chambers by thermal analysis.

Authors:  Hiraku Fuse; Soma Hirota; Tatsuya Fujisaki; Shinji Abe; Kenji Yasue; Koichi Hanada; Fumihiro Tomita
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

4.  Quantifying temperature-equilibrium time using temperature analysis inside a Farmer ionization chamber.

Authors:  Hiraku Fuse; Tatsuya Fujisaki; Shinji Abe; Kenji Yasue; Satoshi Oyama
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

5.  Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration.

Authors:  Pablo Castro; Feliciano García-Vicente; Cristina Mínguez; Alejandro Floriano; David Sevillano; Leopoldo Pérez; Juan J Torres
Journal:  J Appl Clin Med Phys       Date:  2008-01-22       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.