Literature DB >> 2246299

Bone lysis in well-fixed cemented femoral components.

W J Maloney1, M Jasty, A Rosenberg, W H Harris.   

Abstract

We have reviewed 25 cases of focal femoral osteolysis in radiographically stable, cemented femoral implants. In three hips retrieved at post-mortem from two patients, we have been able to make a detailed biomechanical and histological analysis. The interval between arthroplasty and the appearance of focal osteolysis on clinical radiographs ranged from 40 to 168 months, and in over 70% of the cases this did not appear until after five or more years. Few had significant pain and there was no relation to age, sex or original diagnosis. The most common site for osteolysis were Gruen zones 2 and 3 on the anteroposterior radiograph and zones 5 and 6 on the lateral radiograph. In 15 cases (60%), the area of osteolysis corresponded to either a defect in the cement mantle or an area of very thin cement. The rate of progression of these lesions was variable, but to date only one has progressed to gross loosening of the femoral component. The back-scatter scanning electron microscopic examination of serial sections and biomechanical testing of the post-mortem specimens demonstrated focal cement fracture around implants that were otherwise rigidly fixed. In eight cases from which tissue was available, histology showed a histiocytic reaction with evidence of particulate polymethylmethacrylate. We consider that this local fragmentation was the stimulus for local osteolysis in an otherwise stable cemented femoral component.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2246299

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  21 in total

1.  Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements.

Authors:  J L Tipper; P J Firkins; E Ingham; J Fisher; M H Stone; R Farrar
Journal:  J Mater Sci Mater Med       Date:  1999-06       Impact factor: 3.896

2.  Prediction of Charnley femoral stem aseptic loosening by early post-operative radiological features.

Authors:  M H A Malik; N Fisher; J Gray; B M Wroblewski; P R Kay
Journal:  Int Orthop       Date:  2005-08-05       Impact factor: 3.075

3.  [The cemented MS-30 stem. A multi-surgeon series of 333 consecutive cases].

Authors:  M Clauss; T Reitzel; M Pritsch; U J Schlegel; R G Bitsch; V Ewerbeck; H Mau; S J Breusch
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

4.  The influence of surface topography on wear debris generation at the cement/bone interface under cyclic loading.

Authors:  Kirk A Stoffel; Dongliang T Yang; Dwayne Arola
Journal:  J Mater Sci Mater Med       Date:  2007-10-13       Impact factor: 3.896

5.  Neovascularisation and the induction of cell adhesion molecules in response to degradation products from orthopaedic implants.

Authors:  N al-Saffar; J T Mah; Y Kadoya; P A Revell
Journal:  Ann Rheum Dis       Date:  1995-03       Impact factor: 19.103

Review 6.  Total hip arthroplasty.

Authors:  J S Siopack; H E Jergesen
Journal:  West J Med       Date:  1995-03

Review 7.  The biological response to orthopedic implants for joint replacement. II: Polyethylene, ceramics, PMMA, and the foreign body reaction.

Authors:  Emmanuel Gibon; Luis A Córdova; Laura Lu; Tzu-Hua Lin; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-04-15       Impact factor: 3.368

8.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

9.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

10.  Finite element analysis of the effect of cementing concepts on implant stability and cement fatigue failure.

Authors:  Dennis Janssen; Jantien van Aken; Thierry Scheerlinck; Nico Verdonschot
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.