Literature DB >> 22448196

Competitive performance of carbon "quantum" dots in optical bioimaging.

Li Cao1, Sheng-Tao Yang, Xin Wang, Pengju G Luo, Jia-Hui Liu, Sushant Sahu, Yamin Liu, Ya-Ping Sun.   

Abstract

Carbon-based "quantum" dots or carbon dots are surface-functionalized small carbon nanoparticles. For bright fluorescence emissions, the carbon nanoparticles may be surface-doped with an inorganic salt and then the same organic functionalization. In this study, carbon dots without and with the ZnS doping were prepared, followed by gel-column fractionation to harvest dots of 40% and 60% in fluorescence quantum yields, respectively. These highly fluorescent carbon dots were evaluated for optical imaging in mice, from which bright fluorescence images were obtained. Of particular interest was the observed competitive performance of the carbon dots in vivo to that of the well-established CdSe/ZnS QDs. The results suggest that carbon dots may be further developed into a new class of high-performance yet nontoxic contrast agents for optical bioimaging.

Entities:  

Keywords:  Carbon dots; fluorescence; optical bioimaging; quantum dots.

Year:  2012        PMID: 22448196      PMCID: PMC3311233          DOI: 10.7150/thno.3912

Source DB:  PubMed          Journal:  Theranostics        ISSN: 1838-7640            Impact factor:   11.556


1. Introduction

Small carbon nanoparticles have been shown as versatile precursors for brightly fluorescent nano-dots 1-15, with the observed optical properties in solution phenomenologically similar to and performance-wise comparable with those of the well-established semiconductor quantum dots (QDs) 9, 16-19. Structurally, the fluorescent carbon-based “quantum” dots (or often referred to as carbon dots) are small carbon nanoparticles with relatively simple particle surface functionalization 1,2,7,10,11. Carbon dots with oligomeric polyethylene glycol diamine (PEG1500N, Scheme 1/Figure S1) 20 as the surface functionalization agent were shown to be nontoxic 21, amenable to fluorescence bioimaging applications in vitro and in vivo 10,11,22,23. More recently, highly fluorescent carbon dots with emission quantum yields more than 50% were obtained by surface-doping the core carbon nanoparticles with an inorganic salt such as ZnS (Scheme 1/Figure S1) or TiO2 20,24, and/or by applying a gel-column fractionation scheme to the as-synthesized carbon dots samples 9,20. The brighter dots thus harvested promise more and better opportunities for fluorescence bioimaging, especially for uses in vivo to improve the contrast against tissue background. Here we report an experimental validation on the use of these highly fluorescent carbon dots for imaging in mice, with especially a demonstration on the competitive performance of these dots to that of the well-established semiconductor QDs under purposely matching experimental conditions.
Figure S1

(Scheme 1) Cartoon illustrations of non-doped (left) and doped (right) carbon dots 20.

2. Experimental Section

2.1. Materials

Carbon nano-powders, O,O'-bis(3-aminopropyl) polyethylene glycol (MW ~ 1,500, PEG1500N) and thionyl chloride (>99%) were purchased from Aldrich, zinc acetate dihydrate (Zn(OOCCH3)2•2H2O, >98%) and sodium sulfide (Na2S•9H2O, >98%) from Alfa, and nitric acid, N,N-dimethylformamide (DMF, 99%), and sodium dodecyl sulfate (SDS, 99%) from VWR. The aqueous CdSe/ZnS quantum dots solution (Qdot® 525 ITK™ amino (PEG) QDs) was acquired from Invitrogen. Millipore Durapore membrane filters (pore size 0.22 μm) and dialysis membrane tubing were supplied by Spectrum Laboratories. Water was deionized and purified by being passed through a Labconco WaterPros water purification system.

2.2. Measurement

Baxter Megafuge (model 2630) and Beckman-Coulter ultracentrifuge (Optima L90K with a type 90 Ti fixed-angle rotor) were used. UV/vis absorption spectra were recorded on a Shimadzu UV2101-PC spectrophotometer. Fluorescence spectra were measured on a Jobin-Yvon emission spectrometer equipped with a 450 W xenon source, Gemini-180 excitation and Tirax-550 emission monochromators, and a photon counting detector (Hamamatsu R928P PMT at 950 V). Quinine sulfate and 9,10-bis(phenylethynyl)-anthracene were used as standards in the determination of fluorescence quantum yields by the relative method (matching the absorbance at the excitation wavelength between the sample and standard solutions and comparing their corresponding integrated total fluorescence intensities). Atomic force microscopy (AFM) images were acquired in the acoustic AC mode on a Molecular Imaging PicoPlus AFM system equipped with a multipurpose scanner and a NanoWorld point probe NCH sensor. Transmission electron microscopy (TEM) characterization was carried out on Hitachi 9500 TEM and Hitachi HD-2000 S-TEM systems. Confocal fluorescence images were obtained on a Leica laser scanning confocal fluorescence microscope (DM IRE2, with Leica TCS SP2 SE scanning system) equipped with an argon ion laser (JDS Uniphase). The fluorescence imaging in mice was performed on a MAG Biosystems Lumazone FA in vivo Imaging System equipped with an Asahi Max-301 xenon arc source for excitation through a liquid light guide and a Princeton Instruments PIXIS:1024B digital CCD camera system as detector. Band-pass and cut-off filters were used for the selection of excitation and emission wavelengths.

2.3. Carbon Dots

A carbon nano-powder sample (2 g) was refluxed in an aqueous nitric acid solution (2.6 M, 200 mL) for 12 h. The mixture back at room temperature was dialyzed against fresh water, followed by centrifuging at 1,000g to retain the supernatant. The surface-oxidized small carbon nanoparticles recovered from the supernatant (100 mg) were refluxed in neat thionyl chloride for 6 h. Upon the removal of excess thionyl chloride on a rotary evaporator with a vacuum pump, the sample was mixed well with PEG1500N (1 g) in a flask. The mixture was heated to 110 °C, and vigorously stirred at that temperature under nitrogen protection for 3 days. The sample back at room temperature was dispersed in water, followed by centrifuging at 25,000g to retain the supernatant as an aqueous solution of the as-prepared carbon dots. The sample solution was concentrated and then loaded onto a Sephadex G-100TM gel-column packed in house for fractionation 9. Fluorescence quantum yields of the fractions were determined, and those more fluorescent were combined into a single aqueous solution of carbon dots (40% in fluorescence quantum yield) for further characterization and bioimaging. For the surface-doping with ZnS, the surface-oxidized carbon nanoparticles (600 mg) were dispersed in DMF (200 mL) via sonication for 30 min, and to the suspension was first added Zn(OOCCH3)2•2H2O (680 mg, 3.1 mmol) under vigorous stirring and then slow dropwise addition of an aqueous Na2S solution (0.62 M, 5 mL) at room temperature. The mixture was centrifuged at 3,000g, and the precipitate was retained and repeatedly washed with distilled water to obtain the ZnS-doped carbon nanoparticles (881 mg). The ZnS-doped carbon nanoparticles (200 mg) were dispersed in an aqueous SDS solution (1 wt%, 120 mL) via sonication for 30 min. Upon filtration, the filter cake was washed repeatedly with water and then dried. The solid sample was mixed thoroughly with PEG1500N (1.9 g), and the mixture was heated to 110 °C and stirred at that temperature for 72 h under nitrogen protection. The reaction mixture back at room temperature was dispersed in water, followed by centrifuging at 25,000g to retain the supernatant as an aqueous solution of as-prepared CZnS-Dots. The sample solution was similarly concentrated and then fractionated on the same Sephadex G-100TM gel-column 20. Fluorescence quantum yields of the fractions were determined, and those more fluorescent were combined into a single aqueous solution of CZnS-Dots (60% in fluorescence quantum yield) for further characterization and bioimaging.

2.4. Imaging in Mice

All of the animal experiments were performed at Clemson University by strictly following the IACUC (Institutional Animal Care and Use Committee) approved protocols. Female DBA/1 mice (~25 g, acquired from Harlan) were housed in plastic cages (three mice/cage) at the Godley-Snell Research Center at Clemson University and kept on a 12 h light/dark cycle, with food and water provided ad libitum. Following the acclimation of one week, the mice were randomly divided into groups of 3 mice per group for imaging evaluations. Throughout the imaging experiments the mice were kept under anaesthesia (3% isoflurane flow). Two injection modes (subcutaneous and front extremity) were used for the in vivo imaging. Before subcutaneous injection, the back area surrounding the injection point on the mouse was shaved to minimize autofluorescence. The control group in both injection modes was injected with equivalent volume of phosphate buffered saline (PBS). For the front extremity injection, the mice 24 h post-injection were sacrificed by CO2 treatment under anaesthesia. The axillary lymph nodes were dissected for fluorescence imaging. All images were processed and analyzed by using the NIH-commissioned and supplied ImageJ software (http://rsbweb.nih.gov/ij/).

3. Results and Discussion

Small carbon nanoparticles (mostly less than 10 nm in diameter) were harvested from the commercially supplied carbon nano-powders (Aldrich) by first the aqueous nitric acid treatment and then a combination of dialysis to remove impurities and vigorous centrifuging to retain the supernatant. These nanoparticles were functionalized with PEG1500N in classical amidation reaction to yield PEGylated carbon dots (Scheme 1/Figure S1). The as-prepared sample was fractionated on a gel-column (SephadexTM G-100) to harvest the more fluorescent portion of the sample 9, with the corresponding fluorescence quantum yield in the green of 40% (440 nm excitation, figure 1).
Figure 1

Absorption (ABS) and fluorescence (FLSC, 440 nm excitation) spectra of the carbon dots without (upper) and with the ZnS doping (lower) in aqueous solutions, with fluorescence quantum yields of 40% and 60%, respectively. In the insets are photos of the corresponding solutions (excitation at 440 nm and emissions monitored through a 530 nm cut-off filter).

The sample solution was diluted for the preparation of specimens for characterization by microscopy techniques. Both AFM and TEM results showed dot-like images (figure 2), agreeing well with those for carbon dots reported previously 9.
Figure 2

TEM (left) and AFM (right) images of the carbon dots (without ZnS doping) used in the optical imaging experiments.

The carbon nanoparticles could be suspended in aqueous solution in a relatively stable fashion, thus serving as nucleation centers in the titration of zinc acetate with sodium sulfide for the formation of ZnS to yield ZnS-doped carbon nanoparticles 24. The surface-doping level likely varied from particle to particle, so that a surfactant (sodium dodecyl sulfate or SDS)-assisted dispersion procedure in favor of the carbon nanoparticles with more ZnS doping was used to exclude those with no or a negligible level of doping. Subsequently, those nanoparticles with the surface completely covered by ZnS (thus no accessible carboxylic acid moieties on the particle surface for reactions with amino molecules) were discriminated in the functionalization chemistry with PEG1500N 20. The functionalization reaction conditions were similar to those used for carbon dots without the surface doping, resulting in ZnS-doped carbon dots (denoted as CZnS-Dots). According to thermogravimetric analysis (TGA), the estimated core composition in terms of C:ZnS molar ratio in the CZnS-Dots was about 20:1. The as-prepared sample was similarly fractionated on the gel-column to harvest more fluorescent CZnS-Dots 20, with the observed fluorescence quantum yield in the green of 60% (440 nm excitation, figure 1). These dots were diluted for the preparation of specimens for characterization by AFM and TEM, and the representative results are shown in figure 3. The vigorously diluted solution was also used to disperse the dots on cover-glass surface for confocal fluorescence imaging under the same specimen and measurement conditions as those for commercially supplied CdSe/ZnS QDs (Invitrogen Qdot® 525 ITKTM amino (PEG) QDs, fluorescence quantum yield ~60% verified). As shown in figure 4, the well-dispersed CZnS-Dots and the CdSe/ZnS QDs are quite similar in fluorescence brightness at essentially the individual dot level.
Figure 3

Representative TEM (left) and AFM (right) images of the ZnS-doped carbon dots (CZnS-Dots) used in the optical imaging experiments.

Figure 4

Confocal fluorescence images (458 nm excitation, 10 μm for the scale bars) of the CZnS-Dots (left) and the commercially supplied CdSe/ZnS QDs (right). In the inset is a comparison on the average image intensity (IAV) for 60 dots between the two specimens.

The highly fluorescent carbon dots without and with the ZnS doping (quantum yields 40% and 60%, respectively) were evaluated in terms of fluorescence imaging in mice 23. The animal experiments were performed by strictly following the IACUC (Institutional Animal Care and Use Committee) approved protocols. Female DBA/1 mice (~25 g) were housed in plastic cages (three mice/cage) at the Godley-Snell Research Center for animal research at Clemson University on a 12 h light/dark cycle and provided with food and water ad libitum. Following the acclimation of one week, the mice were randomly divided into groups of three mice per group. For the injection and subsequent imaging, the mice were kept under anesthesia with 3% isoflurane flow. Before the subcutaneous injection, the back area surrounding the injection point on the mouse was shaved to avoid autofluorescence. The injection volume was kept at 20 µL, with the solution concentration adjusted to match the targeted optical density at the excitation wavelength. As shown in figure 5, fluorescence emissions from the subcutaneously injected dots could readily be detected in a Lumazone FA in vivo imaging system (MAG Biosystems), with a relatively shorter fluorescence collection time and improved imaging contrast in comparison with those in the use of as-prepared less fluorescent carbon dots 23. The image brightness was obviously higher for the CZnS-Dots sample, consistent with the corresponding higher fluorescence quantum yield in solution. In mice the subcutaneously injected carbon dots diffused relatively slowly, with the gradual fading of fluorescence signals in about 24 h post-injection.
Figure 5

Top: Subcutaneously injected carbon dots (upper spot) and CZnS-Dots (lower spot) of similar optical densities in mice (470 nm and 525 nm band-pass filters for excitation and emission, respectively). Bottom: Subcutaneously injected CZnS-Dots (upper spot) and Invitrogen Qdot® 525 ITKTM amino (PEG) QDs (lower spot) of similar optical densities in mice (434 nm band-pass filter for excitation and 474 nm cut-off filter for emission collection). The color-coded images (right) were processed with ImageJ from NIH.

In a comparison of fluorescence imaging performance with commercially supplied CdSe/ZnS QDs (Invitrogen Qdot® 525 ITKTM amino (PEG) QDs), the concentration of the subcutaneously injected QDs was adjusted such that the optical density was approximately the same as that of the carbon dots in vivo. The resulting fluorescence images for CZnS-Dots and the CdSe/ZnS QDs in mice were of similar brightness (figure 5), consistent with their similar fluorescence quantum yields in solution and comparable fluorescence imaging results at the individual dot level (figure 4). For potential uses of carbon dots for fluorescence imaging in vivo, a relatively straightforward demonstration is on tracking the migration of the dots through lymph vessels in mice following the paw injection 23,25,26. For the highly fluorescent carbon dots without and with ZnS doping (quantum yields 40% and 60%, respectively), they could both migrate along the arm upon their intradermal injection into the front extremity (figure 6). However, the migration of the CZnS-Dots was apparently less pronounced, with the relative brightness in the fluorescence images (figure 6) of the migrated dots suggesting less CZnS-Dots (more fluorescent) migrated. The axillary lymph nodes were harvested and dissected at 24 h post-injection, where strong fluorescence emissions from the carbon dots were observed (figure 6), further confirming the migration of the dots and the preservation of their fluorescence properties in vivo.
Figure 6

Intradermally injected carbon dots (upper) and CZnS-Dots (lower) of similar optical densities in mice, with images of dissected lymph nodes in the insets (470 nm and 525 nm band-pass filters for excitation and emission, respectively). The color-coded images (right) were processed with ImageJ from NIH.

The improved optical imaging performance of these more fluorescent carbon dots in mice further confirms that the excellent fluorescence properties of carbon dots observed in solutions and on surface at the individual dot level are preserved in vivo, suggesting significant application potentials of carbon dots. Particularly encouraging is the fact that the in vivo performance of the carbon dots is competitive to that of the well-established CdSe/ZnS QDs, beyond the obvious advantage of carbon dots being nontoxic according to available experimental evaluations 10,11,21,27-29. The results from this study justify the further development of carbon dots into a new class of high-performance yet benign contrast agents for optical bioimaging.
  18 in total

1.  Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping.

Authors:  Sungjee Kim; Yong Taik Lim; Edward G Soltesz; Alec M De Grand; Jaihyoung Lee; Akira Nakayama; J Anthony Parker; Tomislav Mihaljevic; Rita G Laurence; Delphine M Dor; Lawrence H Cohn; Moungi G Bawendi; John V Frangioni
Journal:  Nat Biotechnol       Date:  2003-12-07       Impact factor: 54.908

2.  Surface functionalized carbogenic quantum dots.

Authors:  Athanasios B Bourlinos; Andreas Stassinopoulos; Demetrios Anglos; Radek Zboril; Michael Karakassides; Emmanuel P Giannelis
Journal:  Small       Date:  2008-04       Impact factor: 13.281

3.  Carbon dots for multiphoton bioimaging.

Authors:  Li Cao; Xin Wang; Mohammed J Meziani; Fushen Lu; Haifang Wang; Pengju G Luo; Yi Lin; Barbara A Harruff; L Monica Veca; Davoy Murray; Su-Yuan Xie; Ya-Ping Sun
Journal:  J Am Chem Soc       Date:  2007-08-28       Impact factor: 15.419

4.  Carbon Dots as Nontoxic and High-Performance Fluorescence Imaging Agents.

Authors:  Sheng-Tao Yang; Xin Wang; Haifang Wang; Fushen Lu; Pengju G Luo; Li Cao; Mohammed J Meziani; Jia-Hui Liu; Yuanfang Liu; Min Chen; Yipu Huang; Ya-Ping Sun
Journal:  J Phys Chem C Nanomater Interfaces       Date:  2009-09-28       Impact factor: 4.126

5.  New strategy for synthesis and functionalization of carbon nanoparticles.

Authors:  Hongquan Jiang; Feng Chen; Max G Lagally; Ferencz S Denes
Journal:  Langmuir       Date:  2010-02-02       Impact factor: 3.882

Review 6.  Quantum dots versus organic dyes as fluorescent labels.

Authors:  Ute Resch-Genger; Markus Grabolle; Sara Cavaliere-Jaricot; Roland Nitschke; Thomas Nann
Journal:  Nat Methods       Date:  2008-09       Impact factor: 28.547

7.  Semiconductor nanocrystals as fluorescent biological labels.

Authors:  M Bruchez; M Moronne; P Gin; S Weiss; A P Alivisatos
Journal:  Science       Date:  1998-09-25       Impact factor: 47.728

8.  Bandgap-like strong fluorescence in functionalized carbon nanoparticles.

Authors:  Xin Wang; Li Cao; Sheng-Tao Yang; Fushen Lu; Mohammed J Meziani; Leilei Tian; Katherine W Sun; Mathew A Bloodgood; Ya-Ping Sun
Journal:  Angew Chem Int Ed Engl       Date:  2010-07-19       Impact factor: 15.336

9.  Toward quantitatively fluorescent carbon-based "quantum" dots.

Authors:  Parambath Anilkumar; Xin Wang; Li Cao; Sushant Sahu; Jia-Hui Liu; Ping Wang; Katerina Korch; Kenneth N Tackett; Alexander Parenzan; Ya-Ping Sun
Journal:  Nanoscale       Date:  2011-02-24       Impact factor: 7.790

10.  An aqueous route to multicolor photoluminescent carbon dots using silica spheres as carriers.

Authors:  Ruili Liu; Dongqing Wu; Shuhua Liu; Kaloian Koynov; Wolfgang Knoll; Qin Li
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

View more
  26 in total

Review 1.  Polymeric materials for theranostic applications.

Authors:  Zhe Wang; Gang Niu; Xiaoyuan Chen
Journal:  Pharm Res       Date:  2013-06-14       Impact factor: 4.200

2.  A Green Synthesis of Carbon Nanoparticle from Honey for Real-Time Photoacoustic Imaging.

Authors:  Lina Wu; Xin Cai; Kate Nelson; Wenxin Xing; Jun Xia; Ruiying Zhang; Allen J Stacy; Micah Luderer; Gregory M Lanza; Lihong V Wang; Baozhong Shen; Dipanjan Pan
Journal:  Nano Res       Date:  2013       Impact factor: 8.897

3.  Light-triggered theranostics based on photosensitizer-conjugated carbon dots for simultaneous enhanced-fluorescence imaging and photodynamic therapy.

Authors:  Peng Huang; Jing Lin; Xiansong Wang; Zhe Wang; Chunlei Zhang; Meng He; Kan Wang; Feng Chen; Zhiming Li; Guangxia Shen; Daxiang Cui; Xiaoyuan Chen
Journal:  Adv Mater       Date:  2012-06-21       Impact factor: 30.849

4.  VEGF-loaded graphene oxide as theranostics for multi-modality imaging-monitored targeting therapeutic angiogenesis of ischemic muscle.

Authors:  Zhongchan Sun; Peng Huang; Guang Tong; Jing Lin; Albert Jin; Pengfei Rong; Lei Zhu; Liming Nie; Gang Niu; Feng Cao; Xiaoyuan Chen
Journal:  Nanoscale       Date:  2013-08-07       Impact factor: 7.790

5.  Gd-encapsulated carbonaceous dots with efficient renal clearance for magnetic resonance imaging.

Authors:  Hongmin Chen; Geoffrey D Wang; Wei Tang; Trever Todd; Zipeng Zhen; Chu Tsang; Khan Hekmatyar; Taku Cowger; Richard Hubbard; Weizhong Zhang; John Stickney; Baozhong Shen; Jin Xie
Journal:  Adv Mater       Date:  2014-09-01       Impact factor: 30.849

Review 6.  Molecular imaging with nanoparticles: the dwarf actors revisited 10 years later.

Authors:  Gudrun C Thurner; Paul Debbage
Journal:  Histochem Cell Biol       Date:  2018-11-16       Impact factor: 4.304

7.  The genotype-dependent influence of functionalized multiwalled carbon nanotubes on fetal development.

Authors:  Xinglu Huang; Fan Zhang; Xiaolian Sun; Ki-Young Choi; Gang Niu; Guofeng Zhang; Jinxia Guo; Seulki Lee; Xiaoyuan Chen
Journal:  Biomaterials       Date:  2014-01       Impact factor: 12.479

8.  Effect of injection routes on the biodistribution, clearance, and tumor uptake of carbon dots.

Authors:  Xinglu Huang; Fan Zhang; Lei Zhu; Ki Young Choi; Ning Guo; Jinxia Guo; Kenneth Tackett; Parambath Anilkumar; Gang Liu; Qimeng Quan; Hak Soo Choi; Gang Niu; Ya-Ping Sun; Seulki Lee; Xiaoyuan Chen
Journal:  ACS Nano       Date:  2013-06-06       Impact factor: 15.881

9.  Carbon-dot-based two-photon visible nanocarriers for safe and highly efficient delivery of siRNA and DNA.

Authors:  Liqin Wang; Xiaoyong Wang; Ashwinkumar Bhirde; Jianbo Cao; Yun Zeng; Xinglu Huang; Yaping Sun; Gang Liu; Xiaoyuan Chen
Journal:  Adv Healthc Mater       Date:  2014-04-02       Impact factor: 9.933

10.  Quantum dots for biophotonics.

Authors:  Ken-Tye Yong
Journal:  Theranostics       Date:  2012-07-04       Impact factor: 11.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.