Literature DB >> 2243675

Rapid determination of intraocular lens tilt and decentration through the undilated pupil.

D L Guyton1, H Uozato, H J Wisnicki.   

Abstract

The apparent optical axis of an implanted intraocular lens (IOL) can be located by alignment of the examiner's hand light with the third and fourth Purkinje images from the front and back surfaces of the IOL. Tilt of the IOL can be estimated (or measured with an arc perimeter) by the angle between the apparent optical axis and the patient's line of sight (actual tilt approximately 0.85 x apparent tilt). Decentration of the IOL is easily detected, equal to the distance of the IOL optical axis from the center of the pupil. This simple technique can be used through the natural pupil with posterior chamber IOLs, providing the optical axis of the malpositioned IOL still passes through the pupil.

Entities:  

Mesh:

Year:  1990        PMID: 2243675     DOI: 10.1016/s0161-6420(90)32422-3

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  11 in total

1.  The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation.

Authors:  Burcu Kemer Atik; Cigdem Altan; Alper Agca; Asli Kirmaci; Yusuf Yildirim; Selim Genc; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2019-11-23       Impact factor: 2.031

2.  Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Authors:  Wenwen He; Xiaodi Qiu; Shaohua Zhang; Yu Du; Yinglei Zhang; Yi Lu; Xiangjia Zhu
Journal:  Eye (Lond)       Date:  2018-03-09       Impact factor: 3.775

3.  Tilt and decentration of bag-fixated intraocular lenses: a comparative study between capsulorhexis and envelope techniques.

Authors:  C Akkin; S A Ozler; J Mentes
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

4.  Feasibility and Complications between Phacoemulsification and Manual Small Incision Surgery in Subluxated Cataract.

Authors:  Ruchi Goel; Saurabh Kamal; Sushil Kumar; Jugal Kishore; K P S Malik; Sonam Angmo Bodh; Smriti Bansal; Madhu Singh
Journal:  J Ophthalmol       Date:  2012-03-05       Impact factor: 1.909

5.  The Effect of Anterior Capsule Polishing on Capsular Contraction and Lens Stability in Cataract Patients with High Myopia.

Authors:  Dandan Wang; Xiaoyu Yu; Zhangliang Li; Xixia Ding; Hengli Lian; Jianyang Mao; Yinying Zhao; Yun-E Zhao
Journal:  J Ophthalmol       Date:  2018-10-23       Impact factor: 1.909

6.  27-gauge trocar-assisted sutureless intraocular lens fixation.

Authors:  Tatsuya Jujo; Jiro Kogo; Hiroki Sasaki; Reio Sekine; Keiji Sato; Sakura Ebisutani; Yasuhiro Toyoda; Yasushi Kitaoka; Hitoshi Takagi
Journal:  BMC Ophthalmol       Date:  2021-01-06       Impact factor: 2.209

7.  Research on calculation of the IOL tilt and decentration based on surface fitting.

Authors:  Lin Li; Ke Wang; Yan Yan; Xudong Song; Zhicheng Liu
Journal:  Comput Math Methods Med       Date:  2013-07-14       Impact factor: 2.238

8.  Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista).

Authors:  Mark Packer; Luther Fry; Kevin T Lavery; Robert Lehmann; James McDonald; Louis Nichamin; Brian Bearie; Jon Hayashida; Griffith E Altmann; Omid Khodai
Journal:  Clin Ophthalmol       Date:  2013-09-24

9.  Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

Authors:  Shuhei Kimura; Yuki Morizane; Yusuke Shiode; Masayuki Hirano; Shinichiro Doi; Shinji Toshima; Atsushi Fujiwara; Fumio Shiraga
Journal:  PLoS One       Date:  2017-09-01       Impact factor: 3.240

Review 10.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14
View more