27-gauge trocar-assisted sutureless intraocular lens fixation.

Tatsuya Jujo1, Jiro Kogo2, Hiroki Sasaki1, Reio Sekine1, Keiji Sato1, Sakura Ebisutani1, Yasuhiro Toyoda1, Yasushi Kitaoka1, Hitoshi Takagi1.   

Abstract

BACKGROUNDS: However there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar.
METHODS: Nineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o'clock, 2 mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications.
RESULTS: The 19 eyes were followed up for 1 month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.06 ± 0.63 and 0.40 ± 0.26, respectively (p < 0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27 ± 0.51 and 0.06 ± 0.15, respectively (p = 0.09). The mean corneal endothelial cell density was 2406 ± 625 to 2004 ± 759 cells/mm2 at 1 month (p = 0.13). The mean IOL tilt was 3.52 ± 3.00°, and the mean IOL decentration was 0.39 ± 0.39 mm. There was no correlation among IOL tilt, decentration and BCVA (p > 0.05). The mean prediction error of the target refraction was - 0.03 ± 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred.
CONCLUSIONS: IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.

Entities:  

Keywords:  27-gauge trocar; 27G vitrectomy; CASIA2; Flange technique; Sutureless intraocular lens fixation

Mesh:

Year:  2021        PMID: 33407262      PMCID: PMC7789339          DOI: 10.1186/s12886-020-01758-6

Source DB:  PubMed          Journal:  BMC Ophthalmol        ISSN: 1471-2415            Impact factor:   2.209


  26 in total

Review 1.  Late in-the-bag intraocular lens dislocation: incidence, prevention, and management.

Authors:  Howard V Gimbel; Garry P Condon; Thomas Kohnen; Randall J Olson; Ioannis Halkiadakis
Journal:  J Cataract Refract Surg       Date:  2005-11       Impact factor: 3.351

2.  Twenty-seven-gauge vitrectomy for various vitreoretinal diseases.

Authors:  Stanislao Rizzo; Francesco Barca; Tomaso Caporossi; Cesare Mariotti
Journal:  Retina       Date:  2015-06       Impact factor: 4.256

3.  Lens guide suture for transport and fixation in secondary IOL implantation after intracapsular extraction.

Authors:  E S Malbran; E Malbran; I Negri
Journal:  Int Ophthalmol       Date:  1986-05       Impact factor: 2.031

4.  27-gauge trocar-assisted transconjunctival sutureless intraocular lens scleral fixation.

Authors:  David Vladimir Diamint; Juan Martin Giambruni
Journal:  Eur J Ophthalmol       Date:  2020-05-13       Impact factor: 2.597

5.  Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique.

Authors:  Shin Yamane; Shimpei Sato; Maiko Maruyama-Inoue; Kazuaki Kadonosono
Journal:  Ophthalmology       Date:  2017-04-27       Impact factor: 12.079

6.  Ab externo scleral suture loop fixation for posterior chamber intraocular lens decentration: clinical results.

Authors:  Clara C Chan; Alan S Crandall; Iqbal Ike K Ahmed
Journal:  J Cataract Refract Surg       Date:  2006-01       Impact factor: 3.351

7.  Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience.

Authors:  Aditya Shrikant Kelkar; Rajesh Fogla; Jai Kelkar; Akshay Anil Kothari; Hetal Mehta; Winfried Amoaku
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

8.  Comparative study of straight vs angled incision in 27-gauge vitrectomy for epiretinal membrane.

Authors:  Ryo Yomoda; Hiroki Sasaki; Jiro Kogo; Akira Shiono; Tatsuya Jujo; Reio Sekine; Naoto Tokuda; Yasushi Kitaoka; Hitoshi Takagi
Journal:  Clin Ophthalmol       Date:  2018-11-26

9.  Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

Authors:  Shuhei Kimura; Yuki Morizane; Yusuke Shiode; Masayuki Hirano; Shinichiro Doi; Shinji Toshima; Atsushi Fujiwara; Fumio Shiraga
Journal:  PLoS One       Date:  2017-09-01       Impact factor: 3.240

10.  27-gauge needle-assisted externalization and haptic securing technique for sutureless scleral fixation of the intraocular lens - moving toward simplicity.

Authors:  Anadi Khatri; Sweta Singh; Roshija Rijal; Bal Kumar Khatri; Muna Kharel
Journal:  Clin Ophthalmol       Date:  2018-08-14
View more
  2 in total

1.  Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation.

Authors:  Teruaki Tokuhisa; Tomoyuki Watanabe; Akira Watanabe; Tadashi Nakano
Journal:  Int Ophthalmol       Date:  2022-01-22       Impact factor: 2.031

2.  Intrascleral Intraocular Lens Fixation Preserving the Lens Capsule in Cases of Cataract with Insufficient Zonular Support.

Authors:  Mutsuko Kato; Michie Namba; Sachika Shimoyama; Mayumi Inoue; Chihiro Ouchi; Takehiro Shimizu
Journal:  Clin Ophthalmol       Date:  2022-01-11
  2 in total