Literature DB >> 22432957

Two-axis acceleration of functional connectivity magnetic resonance imaging by parallel excitation of phase-tagged slices and half k-space acceleration.

Andrzej Jesmanowicz1, Andrew S Nencka, Shi-Jiang Li, James S Hyde.   

Abstract

Whole brain functional connectivity magnetic resonance imaging requires acquisition of a time course of gradient-recalled (GR) volumetric images. A method is developed to accelerate this acquisition using GR echo-planar imaging and radio frequency (RF) slice phase tagging. For N-fold acceleration, a tailored RF pulse excites N slices using a uniform-field transmit coil. This pulse is the Fourier transform of the profile for the N slices with a predetermined RF phase tag on each slice. A multichannel RF receive coil is used for detection. For n slices, there are n/N groups of slices. Signal-averaged reference images are created for each slice within each slice group for each member of the coil array and used to separate overlapping images that are simultaneously received. The time-overhead for collection of reference images is small relative to the acquisition time of a complete volumetric time course. A least-squares singular value decomposition method allows image separation on a pixel-by-pixel basis. Twofold slice acceleration is demonstrated using an eight-channel RF receive coil, with application to resting-state functional magnetic resonance imaging in the human brain. Data from six subjects at 3 T are reported. The method has been extended to half k-space acquisition, which not only provides additional acceleration, but also facilitates slice separation because of increased signal intensity of the central lines of k-space coupled with reduced susceptibility effects.

Entities:  

Mesh:

Year:  2011        PMID: 22432957      PMCID: PMC3312804          DOI: 10.1089/brain.2011.0004

Source DB:  PubMed          Journal:  Brain Connect        ISSN: 2158-0014


  20 in total

1.  Use of multicoil arrays for separation of signal from multiple slices simultaneously excited.

Authors:  D J Larkman; J V Hajnal; A H Herlihy; G A Coutts; I R Young; G Ehnholm
Journal:  J Magn Reson Imaging       Date:  2001-02       Impact factor: 4.813

Review 2.  Resting developments: a review of fMRI post-processing methodologies for spontaneous brain activity.

Authors:  Daniel S Margulies; Joachim Böttger; Xiangyu Long; Yating Lv; Clare Kelly; Alexander Schäfer; Dirk Goldhahn; Alexander Abbushi; Michael P Milham; Gabriele Lohmann; Arno Villringer
Journal:  MAGMA       Date:  2010-10-24       Impact factor: 2.310

3.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging.

Authors:  Felix A Breuer; Martin Blaimer; Robin M Heidemann; Matthias F Mueller; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

4.  Combined simulated annealing and Shinnar-Le Roux pulse design of slice-multiplexed RF pulses for multi-slice imaging.

Authors:  K J Lee; M N J Paley; J M Wild
Journal:  J Magn Reson       Date:  2006-07-07       Impact factor: 2.229

5.  Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA).

Authors:  Felix A Breuer; Martin Blaimer; Matthias F Mueller; Nicole Seiberlich; Robin M Heidemann; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2006-03       Impact factor: 4.668

Review 6.  Generalized encoding through the use of selective excitation in accelerated parallel MRI.

Authors:  Walid E Kyriakos; W Scott Hoge; Dimitris Mitsouras
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

7.  Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

Authors:  A Jesmanowicz; P A Bandettini; J S Hyde
Journal:  Magn Reson Med       Date:  1998-11       Impact factor: 4.668

8.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

9.  Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI.

Authors:  Steen Moeller; Essa Yacoub; Cheryl A Olman; Edward Auerbach; John Strupp; Noam Harel; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

Review 10.  The human connectome: A structural description of the human brain.

Authors:  Olaf Sporns; Giulio Tononi; Rolf Kötter
Journal:  PLoS Comput Biol       Date:  2005-09       Impact factor: 4.475

View more
  11 in total

1.  Functional integration between brain regions at rest occurs in multiple-frequency bands.

Authors:  Suril R Gohel; Bharat B Biswal
Journal:  Brain Connect       Date:  2014-06-25

2.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

3.  Changes in regional cerebral blood flow and functional connectivity in the cholinergic pathway associated with cognitive performance in subjects with mild Alzheimer's disease after 12-week donepezil treatment.

Authors:  Wenjun Li; Piero G Antuono; Chunming Xie; Gang Chen; Jennifer L Jones; B Douglas Ward; Malgorzata B Franczak; Joseph S Goveas; Shi-Jiang Li
Journal:  Neuroimage       Date:  2012-01-08       Impact factor: 6.556

4.  The SENSE-Isomorphism Theoretical Image Voxel Estimation (SENSE-ITIVE) model for reconstruction and observing statistical properties of reconstruction operators.

Authors:  Iain P Bruce; M Muge Karaman; Daniel B Rowe
Journal:  Magn Reson Imaging       Date:  2012-05-21       Impact factor: 2.546

5.  Separation of parallel encoded complex-valued slices (SPECS) from a single complex-valued aliased coil image.

Authors:  Daniel B Rowe; Iain P Bruce; Andrew S Nencka; James S Hyde; Mary C Kociuba
Journal:  Magn Reson Imaging       Date:  2015-11-21       Impact factor: 2.546

Review 6.  Ultra-fast MRI of the human brain with simultaneous multi-slice imaging.

Authors:  David A Feinberg; Kawin Setsompop
Journal:  J Magn Reson       Date:  2013-02-13       Impact factor: 2.229

7.  Evaluation of slice accelerations using multiband echo planar imaging at 3 T.

Authors:  Junqian Xu; Steen Moeller; Edward J Auerbach; John Strupp; Stephen M Smith; David A Feinberg; Essa Yacoub; Kâmil Uğurbil
Journal:  Neuroimage       Date:  2013-07-27       Impact factor: 6.556

8.  Direct radiofrequency phase control in MRI by digital waveform playback at the Larmor frequency.

Authors:  Andrzej Jesmanowicz; Andrew Nencka; James S Hyde
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

9.  Autobiography of James S. Hyde.

Authors:  James S Hyde
Journal:  Appl Magn Reson       Date:  2017-10-27       Impact factor: 0.831

10.  Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging.

Authors:  Andrew M Huettner; Nikolai J Mickevicius; Ali Ersoz; Kevin M Koch; L Tugan Muftuler; Andrew S Nencka
Journal:  PLoS One       Date:  2015-10-30       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.