Literature DB >> 9797160

Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla.

A Jesmanowicz1, P A Bandettini, J S Hyde.   

Abstract

Half k-space gradient-recalled echo-planar imaging (GR-EPI) is discussed in detail. T2* decay during full k-space GR-EPI gives rise to unequal weighting of the lines of k-space, loss of signal intensity at the center of k-space, and a point-spread function that limits resolution. In addition, the long readout time for high-resolution full k-space acquisition gives rise to severe susceptibility effects. These problems are substantially reduced by acquiring only half of k-space and filling the empty side by Hermitian conjugate formation. Details of the pulse sequence and image reconstruction are presented. The point-spread function is 3(1/2) times narrower for half than full k-space acquisition. Experiments as well as theoretical considerations were carried out in a context of fMRI using a whole-brain local gradient and an RF coil at 3 Tesla. Using a bandwidth of +/-83 kHz, well-resolved single-shot images of the human brain, as well as good quality fMRI data sets were obtained with a matrix of 192 x 192 over 16 x 16 cm2 FOV using half k-space techniques. The combination of high spatial resolution using the methods presented in this article and the high temporal resolution of EPI opens opportunities for research into fMRI contrast mechanisms. Increase of percent signal change as the resolution increases is attributed to reduction of partial volume effects of activated voxels. Histograms of fMRI pixel responses are progressively weighted to higher percent signal changes as the resolution increases. The conclusion has been reached that half k-space GR-EPI is generally superior to full k-space GR-EPI and should be used even for low-resolution (64 x 64) EPI.

Entities:  

Mesh:

Year:  1998        PMID: 9797160     DOI: 10.1002/mrm.1910400517

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

Review 1.  Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Authors:  A M Howseman; R W Bowtell
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

2.  Two-axis acceleration of functional connectivity magnetic resonance imaging by parallel excitation of phase-tagged slices and half k-space acceleration.

Authors:  Andrzej Jesmanowicz; Andrew S Nencka; Shi-Jiang Li; James S Hyde
Journal:  Brain Connect       Date:  2011

3.  Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla.

Authors:  Amir Shmuel; Essa Yacoub; Denis Chaimow; Nikos K Logothetis; Kamil Ugurbil
Journal:  Neuroimage       Date:  2007-01-04       Impact factor: 6.556

4.  Imaging mesial temporal lobe activation during scene encoding: comparison of fMRI using BOLD and arterial spin labeling.

Authors:  María A Fernández-Seara; Jiongjiong Wang; Ze Wang; Marc Korczykowski; Matthias Guenther; David A Feinberg; John A Detre
Journal:  Hum Brain Mapp       Date:  2007-12       Impact factor: 5.038

5.  K-space spatial low-pass filters can increase signal loss artifacts in Echo-Planar Imaging.

Authors:  E C Caparelli; D Tomasi
Journal:  Biomed Signal Process Control       Date:  2008-01       Impact factor: 3.880

6.  Improved image reconstruction for partial Fourier gradient-echo echo-planar imaging (EPI).

Authors:  Nan-kuei Chen; Koichi Oshio; Lawrence P Panych
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

7.  Three dimensional echo-planar imaging at 7 Tesla.

Authors:  B A Poser; P J Koopmans; T Witzel; L L Wald; M Barth
Journal:  Neuroimage       Date:  2010-02-06       Impact factor: 6.556

8.  High spatial resolution compressed sensing (HSPARSE) functional MRI.

Authors:  Zhongnan Fang; Nguyen Van Le; ManKin Choy; Jin Hyung Lee
Journal:  Magn Reson Med       Date:  2015-10-29       Impact factor: 4.668

9.  BOLD responses to different temporal frequency stimuli in the lateral geniculate nucleus and visual cortex: insights into the neural basis of fMRI.

Authors:  Cecil Chern-Chyi Yen; Mitsuhiro Fukuda; Seong-Gi Kim
Journal:  Neuroimage       Date:  2011-06-17       Impact factor: 6.556

10.  High spatiotemporal vessel-specific hemodynamic mapping with multi-echo single-vessel fMRI.

Authors:  Yi He; Maosen Wang; Xin Yu
Journal:  J Cereb Blood Flow Metab       Date:  2019-11-07       Impact factor: 6.200

View more