Literature DB >> 15259636

Quantitation of respiratory motion during 4D-PET/CT acquisition.

S A Nehmeh1, Y E Erdi, T Pan, E Yorke, G S Mageras, K E Rosenzweig, H Schoder, H Mostafavi, O Squire, A Pevsner, S M Larson, J L Humm.   

Abstract

We report on the variability of the respiratory motion during 4D-PET/CT acquisition. The respiratory motion for five lung cancer patients was monitored by tracking external markers placed on the abdomen. CT data were acquired over an entire respiratory cycle at each couch position. The x-ray tube status was recorded by the tracking system, for retrospective sorting of the CT data as a function of respiration phase. Each respiratory cycle was sampled in ten equal bins. 4D-PET data were acquired in gated mode, where each breathing cycle was divided into ten 500 ms bins. For both CT and PET acquisition, patients received audio prompting to regularize breathing. The 4D-CT and 4D-PET data were then correlated according to their respiratory phases. The respiratory periods, and average amplitude within each phase bin, acquired in both modality sessions were then analyzed. The average respiratory motion period during 4D-CT was within 18% from that in the 4D-PET sessions. This would reflect up to 1.8% fluctuation in the duration of each 4D-CT bin. This small uncertainty enabled good correlation between CT and PET data, on a phase-to-phase basis. Comparison of the average-amplitude within the respiration trace, between 4D-CT and 4D- PET, on a bin-by-bin basis show a maximum deviation of approximately 15%. This study has proved the feasibility of performing 4D-PET/CT acquisition. Respiratory motion was in most cases consistent between PET and CT sessions, thereby improving both the attenuation correction of PET images, and co-registration of PET and CT images. On the other hand, in two patients, there was an increased partial irregularity in their breathing motion, which would prevent accurately correlating the corresponding PET and CT images.

Entities:  

Mesh:

Year:  2004        PMID: 15259636     DOI: 10.1118/1.1739671

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  57 in total

1.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Attenuation correction in cardiac PET/CT with three different CT protocols: a comparison with conventional PET.

Authors:  Michael Souvatzoglou; Frank Bengel; Raymonde Busch; Coletta Kruschke; Helga Fernolendt; Denise Lee; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07-28       Impact factor: 9.236

3.  Broadening the scope of image-guided radiotherapy (IGRT).

Authors:  Carlo Greco; C Clifton Ling
Journal:  Acta Oncol       Date:  2008       Impact factor: 4.089

4.  Quantification of the thorax-to-abdomen breathing ratio for breathing motion modeling.

Authors:  Benjamin M White; Tianyu Zhao; James Lamb; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

5.  PET/CT imaging: effect of respiratory motion on apparent myocardial uptake.

Authors:  Ludovic Le Meunier; Roberto Maass-Moreno; Jorge A Carrasquillo; William Dieckmann; Stephen L Bacharach
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

6.  Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions.

Authors:  Loïc Fin; Joël Daouk; Julie Morvan; Pascal Bailly; Isabelle El Esper; Lazhar Saidi; Marc-Etienne Meyer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

7.  Dual gated PET/CT imaging of small targets of the heart: method description and testing with a dynamic heart phantom.

Authors:  Tommi Kokki; Hannu T Sipilä; Mika Teräs; Tommi Noponen; Nicolas Durand-Schaefer; Riku Klén; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2010 Jan-Feb       Impact factor: 5.952

8.  Retrospective 4D MR image construction from free-breathing slice Acquisitions: A novel graph-based approach.

Authors:  Yubing Tong; Jayaram K Udupa; Krzysztof C Ciesielski; Caiyun Wu; Joseph M McDonough; David A Mong; Robert M Campbell
Journal:  Med Image Anal       Date:  2016-08-13       Impact factor: 8.545

Review 9.  State-of-the-art molecular imaging in esophageal cancer management: implications for diagnosis, prognosis, and treatment.

Authors:  Jolinta Lin; Seth Kligerman; Rakhi Goel; Payam Sajedi; Mohan Suntharalingam; Michael D Chuong
Journal:  J Gastrointest Oncol       Date:  2015-02

10.  Respiration-averaged CT for attenuation correction in non-small-cell lung cancer.

Authors:  Nai-Ming Cheng; Chih-Teng Yu; Kung-Chu Ho; Yi-Cheng Wu; Yuan-Chang Liu; Chih-Wei Wang; Tzu-Chen Yen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12-03       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.