Literature DB >> 31660320

Accuracy of non-invasive and minimally invasive hemodynamic monitoring: where do we stand?

Issa Pour-Ghaz1, Theodore Manolukas1, Nathalie Foray2, Joel Raja1, Aranyak Rawal1, Uzoma N Ibebuogu1, Rami N Khouzam1.   

Abstract

One of the most important variables in assessing hemodynamic status in the intensive care unit (ICU) is the cardiac function and blood pressure. Invasive methods such as pulmonary artery catheter and arterial line allow monitoring of blood pressure and cardiac function accurately and reliably. However, their use is not without drawbacks, especially when the invasive nature of these procedures and complications associated with them are considered. There are several newer methods of noninvasive and minimally invasive hemodynamic monitoring available. In this manuscript, we will review these different methods of minimally invasive and non-invasive hemodynamic monitoring and will discuss their advantages, drawbacks and limitations. 2019 Annals of Translational Medicine. All rights reserved.

Entities:  

Keywords:  Hemodynamic monitoring; cardiac output; continuous monitoring; minimally invasive; non-invasive

Year:  2019        PMID: 31660320      PMCID: PMC6787372          DOI: 10.21037/atm.2019.07.06

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


  92 in total

1.  Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device.

Authors:  B Saugel; A S Meidert; A Hapfelmeier; F Eyer; R M Schmid; W Huber
Journal:  Br J Anaesth       Date:  2013-03-13       Impact factor: 9.166

Review 2.  Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis.

Authors:  Sang-Hyun Kim; Marc Lilot; Kulraj S Sidhu; Joseph Rinehart; Zhaoxia Yu; Cecilia Canales; Maxime Cannesson
Journal:  Anesthesiology       Date:  2014-05       Impact factor: 7.892

3.  Perioperative Noninvasive Blood Pressure Monitoring.

Authors:  Kai Kuck; Philip D Baker
Journal:  Anesth Analg       Date:  2018-08       Impact factor: 5.108

4.  Relationship between Intraoperative Hypotension, Defined by Either Reduction from Baseline or Absolute Thresholds, and Acute Kidney and Myocardial Injury after Noncardiac Surgery: A Retrospective Cohort Analysis.

Authors:  Vafi Salmasi; Kamal Maheshwari; Dongsheng Yang; Edward J Mascha; Asha Singh; Daniel I Sessler; Andrea Kurz
Journal:  Anesthesiology       Date:  2017-01       Impact factor: 7.892

5.  The impact of continuous non-invasive arterial blood pressure monitoring on blood pressure stability during general anaesthesia in orthopaedic patients: A randomised trial.

Authors:  Agnes S Meidert; Johanna S Nold; Roman Hornung; Alexander C Paulus; Bernhard Zwißler; Stephan Czerner
Journal:  Eur J Anaesthesiol       Date:  2017-11       Impact factor: 4.330

6.  Noninvasive continuous arterial blood pressure monitoring with Nexfin®.

Authors:  Jerson R Martina; Berend E Westerhof; Jeroen van Goudoever; Edouard M F H de Beaumont; Jasper Truijen; Yu-Sok Kim; Rogier V Immink; Dorothea A Jöbsis; Markus W Hollmann; Jaap R Lahpor; Bas A J M de Mol; Johannes J van Lieshout
Journal:  Anesthesiology       Date:  2012-05       Impact factor: 7.892

7.  Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour.

Authors:  Julia Y Wagner; Julian Grond; Jürgen Fortin; Ileana Negulescu; Miriam Schöfthaler; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-07-31       Impact factor: 2.502

8.  Accuracy of the CNAP monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in the prone position.

Authors:  Elisabeth Dewhirst; Marco Corridore; Jan Klamar; Allan Beebe; Julie Rice; N'diris Barry; Joseph D Tobias
Journal:  J Clin Anesth       Date:  2013-05-17       Impact factor: 9.452

9.  Nexfin noninvasive continuous hemodynamic monitoring: validation against continuous pulse contour and intermittent transpulmonary thermodilution derived cardiac output in critically ill patients.

Authors:  Koen Ameloot; Katrijn Van De Vijver; Ole Broch; Niels Van Regenmortel; Inneke De Laet; Karen Schoonheydt; Hilde Dits; Berthold Bein; Manu L N G Malbrain
Journal:  ScientificWorldJournal       Date:  2013-11-11

10.  Evaluation of cardiac output by 5 arterial pulse contour techniques using trend interchangeability method.

Authors:  Marc-Olivier Fischer; Momar Diouf; Robert B P de Wilde; Hervé Dupont; Jean-Luc Hanouz; Emmanuel Lorne
Journal:  Medicine (Baltimore)       Date:  2016-06       Impact factor: 1.889

View more
  8 in total

1.  Guide to Enhanced Recovery for Cancer Patients Undergoing Surgery: ERAS for Patients Undergoing Cytoreductive Surgery with or Without HIPEC.

Authors:  Ankit Dhiman; Emily Fenton; Jeffrey Whitridge; Jennifer Belanski; Whitney Petersen; Sarah Macaraeg; Govind Rangrass; Ardaman Shergill; Dejan Micic; Oliver S Eng; Kiran Turaga
Journal:  Ann Surg Oncol       Date:  2021-05-05       Impact factor: 5.344

Review 2.  Hemodynamic monitoring in patients with venoarterial extracorporeal membrane oxygenation.

Authors:  Ying Su; Kai Liu; Ji-Li Zheng; Xin Li; Du-Ming Zhu; Ying Zhang; Yi-Jie Zhang; Chun-Sheng Wang; Tian-Tian Shi; Zhe Luo; Guo-Wei Tu
Journal:  Ann Transl Med       Date:  2020-06

3.  Evaluation of radial artery pulse pressure effects on detection of stroke volume changes after volume loading maneuvers in cardiac surgical patients.

Authors:  Jun-Yi Hou; Ji-Li Zheng; Guo-Guang Ma; Xiao-Ming Lin; Guang-Wei Hao; Ying Su; Jing-Chao Luo; Kai Liu; Zhe Luo; Guo-Wei Tu
Journal:  Ann Transl Med       Date:  2020-06

Review 4.  How to monitor cardiovascular function in critical illness in resource-limited settings.

Authors:  Chaisith Sivakorn; Marcus J Schultz; Arjen M Dondorp
Journal:  Curr Opin Crit Care       Date:  2021-06-01       Impact factor: 3.359

Review 5.  Microcirculation during surgery.

Authors:  Karam Nam; Yunseok Jeon
Journal:  Anesth Pain Med (Seoul)       Date:  2022-01-21

6.  Comparing Cardiac Output Measurements Using a Wearable, Wireless, Noninvasive Photoplethysmography-Based Device to Pulse Contour Cardiac Output in the General ICU: A Brief Report.

Authors:  Ayana Dvir; Nir Goldstein; Avigal Rapoport; Ronen Gingy Balmor; Dean Nachman; Roei Merin; Meir Fons; Arik Ben Ishay; Arik Eisenkraft
Journal:  Crit Care Explor       Date:  2022-02-01

7.  Beat-to-beat blood pressure variability in patients with obstructive sleep apnea.

Authors:  Amrita Pal; Fernando Martinez; Andrea P Aguila; Margaret A Akey; Roopsha Chatterjee; Merry Grace E Conserman; Ravi S Aysola; Luke A Henderson; Paul M Macey
Journal:  J Clin Sleep Med       Date:  2021-03-01       Impact factor: 4.062

Review 8.  Blood Pressure Sensors: Materials, Fabrication Methods, Performance Evaluations and Future Perspectives.

Authors:  Ahmed Al-Qatatsheh; Yosry Morsi; Ali Zavabeti; Ali Zolfagharian; Nisa Salim; Abbas Z Kouzani; Bobak Mosadegh; Saleh Gharaie
Journal:  Sensors (Basel)       Date:  2020-08-11       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.