Literature DB >> 30046532

Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases.

Ming-Yu Shi1, Xiao Han1, Jin-Song Zhang1, Qi-Chang Yan1.   

Abstract

AIM: To compare the results of 25 MHz and 50 MHz ultrasound biomicroscopy (UBM) regarding the image characteristics of the lens and its related diseases and to discuss the application value of 25 MHz UBM in ophthalmology.
METHODS: A total of 302 patients (455 eyes) were included in this study from November 2014 to May 2015. Patient ages ranged from 5 to 89y (mean±SD: 61.0±17.7y). Different cross-sectional images of the lens were collected to compare and analyze the image characteristics and anterior segment parameters using 25 MHz and 50 MHz UBM in axial and longitudinal scanning modes, respectively. SPSS 19.0 for Windows, paired t-tests and B&A plot analysis were used for data analysis, and a value of P<0.05 was considered statistically significant.
RESULTS: The 25 MHz UBM images displayed the lens shape more clearly than 50 MHz UBM images. Particularly for cataracts, the whole opacity of the lens was shown by 25 MHz UBM, but 50 MHz UBM only showed part of the lens. The means of the anterior segment parameters obtained using 25 MHz and 50 MHz UBM were as follows: central corneal thickness: 0.55±0.03 and 0.51±0.04 mm, respectively; central anterior chamber depth: 2.48±0.54 and 2.56±0.56 mm, respectively; and central lens thickness: 4.26±0.62 and 4.15±0.56 mm, respectively. A statistically significant difference was found between the results obtained with 25 MHz UBM and those obtained with 50 MHz UBM. The two devices had a good agreement in measuring the anterior segment parameters.
CONCLUSION: The 25 MHz UBM had an obvious advantage in showing the lens shape. It can provide reliable imaging of the lens and its related diseases and has a high application value for ophthalmology.

Entities:  

Keywords:  25 MHz ultrasound biomicroscopy; 50 MHz ultrasound biomicroscopy; lens diseases

Year:  2018        PMID: 30046532      PMCID: PMC6048332          DOI: 10.18240/ijo.2018.07.13

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  23 in total

Review 1.  Advances in ultrasound biomicroscopy.

Authors:  F S Foster; C J Pavlin; K A Harasiewicz; D A Christopher; D H Turnbull
Journal:  Ultrasound Med Biol       Date:  2000-01       Impact factor: 2.998

2.  Visualization of posterior lens capsule integrity by 20-MHz ultrasound probe in ocular trauma.

Authors:  Tuong-Nam Nguyen; Magdi Mansour; Jean Deschenes; Susan Lindley
Journal:  Am J Ophthalmol       Date:  2003-10       Impact factor: 5.258

3.  Clinical use of ultrasound biomicroscopy.

Authors:  C J Pavlin; K Harasiewicz; M D Sherar; F S Foster
Journal:  Ophthalmology       Date:  1991-03       Impact factor: 12.079

4.  Clinical application of a Scheimpflug system for lens density measurements in phacoemulsification.

Authors:  Jung-Sub Kim; So-Hyang Chung; Choun-Ki Joo
Journal:  J Cataract Refract Surg       Date:  2009-07       Impact factor: 3.351

5.  Comparison of anterior chamber depth measurements taken with the Pentacam, Orbscan IIz and IOLMaster in myopic and emmetropic eyes.

Authors:  Canan Asli Utine; Feyza Altin; Hanefi Cakir; Irfan Perente
Journal:  Acta Ophthalmol       Date:  2008-09-05       Impact factor: 3.761

6.  Anterior segment optical coherence tomography characteristics in an Asian population.

Authors:  Ramanjit Sihota; Praveen Vashisht; Ajay Sharma; Swapna Chakraborty; Viney Gupta; Ravindra M Pandey
Journal:  J Glaucoma       Date:  2012-03       Impact factor: 2.503

7.  Allvar Gullstrand and the slit lamp 1911.

Authors:  P J Timoney; C S Breathnach
Journal:  Ir J Med Sci       Date:  2012-12-21       Impact factor: 1.568

8.  Correlation of nuclear density using the Lens Opacity Classification System III versus Scheimpflug imaging with phacoemulsification parameters.

Authors:  Monika Gupta; Jagat Ram; Arun Jain; Jaspreet Sukhija; Manish Chaudhary
Journal:  J Cataract Refract Surg       Date:  2013-12       Impact factor: 3.351

9.  Preoperative detection of posterior capsule tear with ultrasound biomicroscopy in traumatic cataract.

Authors:  Murat Kucukevcilioglu; Volkan Hurmeric; Osman Melih Ceylan
Journal:  J Cataract Refract Surg       Date:  2013-02       Impact factor: 3.351

Review 10.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

View more
  6 in total

1.  Establishing a novel lens opacities classification system based on ultrasound biomicroscopy (UBM) for pediatric cataracts: reliability and availability.

Authors:  Dao-Man Xiang; Nan Jiang; Li-Hong Chen; Wen-Si Chen; Ying Yu; Jian-Xun Wang; Ping He; Wan-Hua Xie
Journal:  Quant Imaging Med Surg       Date:  2021-11

2.  Femtosecond laser-assisted cataract surgery in management of posterior capsule tear following blunt trauma: Case report and review of literature.

Authors:  Alisa J Prager; Surendra Basti
Journal:  Am J Ophthalmol Case Rep       Date:  2020-05-16

3.  Clinical Application of 25-MHz Ultrasound Biomicroscopy for Lens Opacity Degree Measurements in Phacoemulsification.

Authors:  Fangkun Zhao; Jiaming Yu; Qichang Yan; Jinsong Zhang; Mingyu Shi
Journal:  Transl Vis Sci Technol       Date:  2019-08-07       Impact factor: 3.283

4.  Quadruple ultrasound, photoacoustic, optical coherence, and fluorescence fusion imaging with a transparent ultrasound transducer.

Authors:  Jeongwoo Park; Byullee Park; Tae Yeong Kim; Sungjin Jung; Woo June Choi; Joongho Ahn; Dong Hee Yoon; Jeongho Kim; Seungwan Jeon; Donghyun Lee; Uijung Yong; Jinah Jang; Won Jong Kim; Hong Kyun Kim; Unyong Jeong; Hyung Ham Kim; Chulhong Kim
Journal:  Proc Natl Acad Sci U S A       Date:  2021-03-16       Impact factor: 11.205

5.  Lens Biometry in Congenital Lens Deformities: A Swept-Source Anterior Segment OCT Analysis.

Authors:  Ze-Xu Chen; Wan-Nan Jia; Yong-Xiang Jiang
Journal:  Front Med (Lausanne)       Date:  2021-12-20

6.  Correlation Between Degree of Lens Opacity and the Phacoemulsification Energy Parameters Using Different Imaging Methods in Age-Related Cataract.

Authors:  Li Feng; Fangkun Zhao; Xin Ke; Jiangyue Zhao; Mingyu Shi
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.