Literature DB >> 22383130

Step frequency and lower extremity loading during running.

H Hobara1, T Sato, M Sakaguchi, T Sato, K Nakazawa.   

Abstract

The purpose of the present study was to ascertain whether increase in step frequency at a given velocity during running reduces the lower extremity loading variables, which is associated with tibial stress fracture in runner. We hypothesized that the lower extremity loading variables at a given speed would be minimized at around +15% f step. 10 male subjects were asked to run at 2.5 m/s on a treadmill-mounted force platform. 5 step frequencies were controlled using a metronome: the preferred, below preferred (-15 and -30%) and above preferred (+15 and +30%). From the vertical ground reaction force, we measured following lower extremity loading variables; vertical impact peak (VIP), vertical instantaneous loading rate (VILR) and vertical average loading rate (VALR). We found that there were significant differences in lower extremity loading variables among 5 step frequency conditions. Furthermore, quadratic regression analyses revealed that the minimum loading variable frequencies were 17.25, 17.55, and 18.07% of preferred step frequency for VIP, VILR and VIAR, respectively. Thus, adopting a step frequency greater than one's preferred may be practical in reducing the risk of developing a tibial stress fracture by decreasing lower extremity loading variables. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 22383130     DOI: 10.1055/s-0031-1291232

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  37 in total

1.  EFFECTS OF NORMAL AGING ON LOWER EXTREMITY LOADING AND COORDINATION DURING RUNNING IN MALES AND FEMALES.

Authors:  Paul W Kline; D S Blaise Williams
Journal:  Int J Sports Phys Ther       Date:  2015-11

2.  Determining if muscle activity is related to preferred stride frequency during running in the water and on land.

Authors:  Kenji Masumoto; Joshua P Bailey; John A Mercer
Journal:  Eur J Appl Physiol       Date:  2015-08-09       Impact factor: 3.078

Review 3.  The biomechanical differences between barefoot and shod distance running: a systematic review and preliminary meta-analysis.

Authors:  Jonathan P L Hall; Christian Barton; Paul Remy Jones; Dylan Morrissey
Journal:  Sports Med       Date:  2013-12       Impact factor: 11.136

4.  PERFORMANCE OPTIMIZATION AND INJURY PREVENTION STRATEGIES FOR THE ARMY PHYSICAL FITNESS TEST: TECHNIQUE MATTERS.

Authors:  Mark Thelen; Shane Koppenhaver
Journal:  Int J Sports Phys Ther       Date:  2015-06

5.  Effect of Acute Alterations in Foot Strike Patterns during Running on Sagittal Plane Lower Limb Kinematics and Kinetics.

Authors:  Kevin A Valenzuela; Scott K Lynn; Lisa R Mikelson; Guillermo J Noffal; Daniel A Judelson
Journal:  J Sports Sci Med       Date:  2015-03-01       Impact factor: 2.988

6.  Treatment of distal iliotibial band syndrome in a long distance runner with gait re-training emphasizing step rate manipulation.

Authors:  Darrell J Allen
Journal:  Int J Sports Phys Ther       Date:  2014-04

7.  THE EFFECT OF STEP RATE MANIPULATION ON FOOT STRIKE PATTERN OF LONG DISTANCE RUNNERS.

Authors:  Darrell J Allen; Hollie Heisler; Jennifer Mooney; Richard Kring
Journal:  Int J Sports Phys Ther       Date:  2016-02

8.  Update on stress fractures in female athletes: epidemiology, treatment, and prevention.

Authors:  Yin-Ting Chen; Adam S Tenforde; Michael Fredericson
Journal:  Curr Rev Musculoskelet Med       Date:  2013-06

Review 9.  An Evidence-Based Videotaped Running Biomechanics Analysis.

Authors:  Richard B Souza
Journal:  Phys Med Rehabil Clin N Am       Date:  2015-10-20       Impact factor: 1.784

10.  Acute changes in foot strike pattern and cadence affect running parameters associated with tibial stress fractures.

Authors:  Jennifer R Yong; Amy Silder; Kate L Montgomery; Michael Fredericson; Scott L Delp
Journal:  J Biomech       Date:  2018-05-18       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.