Literature DB >> 22381263

Longitudinal stent deformation: insights on mechanisms, treatments and outcomes from the Food and Drug Administration Manufacturer and User Facility Device Experience database.

Mamas A Mamas1, Paul D Williams.   

Abstract

AIMS: Longitudinal stent deformation (LSD) is a recently described complication of PCI, but mechanisms contributing to its occurrence and associated clinical outcomes remain unclear. The FDA Manufacturer and User Facility Device Experience (MAUDE) database was searched to identify cases of LSD to gain insight into procedural and anatomical factors that predispose to this complication and associated clinical outcomes. METHODS AND
RESULTS: The MAUDE database is a voluntary international electronic reporting system whose aim is to capture major adverse events involving medical devices. Using defined search terms, we identified 57 unique cases of LSD ranging from 2004-2011. A significant increase in the reporting of LSD in the last two years was observed with most reported cases in stents based on the Element platform (90%). The lesions in which LSD was reported were complex (vessel calcification 26%; tortuosity 25%; long 28%; ostial disease 21%) and most frequently occurred following attempts to pass or withdraw secondary devices through a previously deployed stent (89% cases where mechanism identified). Adverse clinical outcomes including emergent cardiac surgery and acute and sub-acute stent thrombosis occurred in eight cases.
CONCLUSIONS: LSD can occur secondary to a variety of mechanisms; identification and treatment is important since adverse incidents such as emergent CABG and stent thrombosis may occur. A novel classification system is proposed to facilitate future reporting of this complication.

Entities:  

Mesh:

Year:  2012        PMID: 22381263     DOI: 10.4244/EIJV8I2A33

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  18 in total

1.  Stent fracture and longitudinal compression detected on coronary CT angiography in the first- and new-generation drug-eluting stents.

Authors:  Mi Sun Chung; Dong Hyun Yang; Young-Hak Kim; Jae-Hyung Roh; Jihyun Song; Joon-Won Kang; Jung-Min Ahn; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Cheol Whan Lee; Seong-Wook Park; Seung-Jung Park; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2015-10-26       Impact factor: 2.357

2.  The potential hazard of a non-slip element balloon causing distal longitudinal stent deformation: the first clinical experience and in vitro assessment.

Authors:  Hiroki Shibutani; Yuzo Akita; Yohei Oishi; Hiroyuki Sueyoshi; Yu Mukai; Kotaro Yutaka; Yumie Matsui; Masahiro Yoshinaga; Masahiro Karakawa
Journal:  Cardiol J       Date:  2018-06-20       Impact factor: 2.737

3.  Occurrence of longitudinal stent compression before stent deployment: Two case studies.

Authors:  Adel Aminian; Jacques Lalmand; Dariouch Dolatabadi
Journal:  World J Cardiol       Date:  2014-01-26

4.  Needles in Our Technology Haystacks: Defining Efficacy Is Easy, Characterizing Complications Is the Challenge.

Authors:  Elazer R Edelman; Pei-Jiang Wang
Journal:  Circ Cardiovasc Interv       Date:  2017-11       Impact factor: 6.546

5.  Accordion Stent Deformation upon Retrieval of a Side-Branch Protective Guidewire.

Authors:  Shih-Tsung Cheng; Cheng-Wen Su; Chiau-Suong Liau; Yu-Lin Ko
Journal:  Acta Cardiol Sin       Date:  2015-11       Impact factor: 2.672

6.  Should ultrathin strut drug eluting stents be considered the new benchmark for novel coronary stents approval? The complex interplay between stent strut thickness, polymeric carriers and antiproliferative drugs.

Authors:  Alessandro Lupi; Alon Schaffer; Angelo Sante Bongo
Journal:  J Thorac Dis       Date:  2018-02       Impact factor: 2.895

7.  Stent accordion phenomenon visualized with optical coherence tomography.

Authors:  Lucky R Cuenza; Khung Keong Yeo
Journal:  Cardiovasc Diagn Ther       Date:  2017-12

8.  Clinical, angiographic and procedural characteristics of longitudinal stent deformation.

Authors:  A Guler; Y Guler; E Acar; S M Aung; S C Efe; A Kilicgedik; C Y Karabay; S Barutcu; M K Tigen; S Pala; A İzgi; A M Esen; C Kirma
Journal:  Int J Cardiovasc Imaging       Date:  2016-05-19       Impact factor: 2.357

9.  Longitudinal Stent Deformation at Aneurysm Site: Flexibility at the Expense of Longitudinal Integrity.

Authors:  Bhupesh R Shah
Journal:  J Clin Diagn Res       Date:  2017-07-01

10.  A novel platinum chromium everolimus-eluting stent for the treatment of coronary artery disease.

Authors:  Johan Bennett; Christophe Dubois
Journal:  Biologics       Date:  2013-06-19
View more