Literature DB >> 22376091

Update on the biological effects of ionizing radiation, relative dose factors and radiation hygiene.

Stuart C White1, S M Mallya.   

Abstract

Diagnostic imaging is an indispensable part of contemporary medical and dental practice. Over the last few decades there has been a dramatic increase in the use of ionizing radiation for diagnostic imaging. The carcinogenic effects of high-dose exposure are well known. Does diagnostic radiation rarely cause cancer? We don't know but we should act as if it does. Accordingly, dentists should select patients wisely - only make radiographs when there is patient-specific reason to believe there is a reasonable expectation the radiograph will offer unique information influencing diagnosis or treatment. Low-dose examinations should be made: intraoral imaging - use fast film or digital sensors, thyroid collars, rectangular collimation; panoramic and lateral cephalometric imaging - use digital systems or rare-earth film screen combinations; and cone beam computed tomography - use low-dose machines, restrict field size to region of interest, reduce mA and length of exposure arc as appropriate.
© 2012 Australian Dental Association.

Entities:  

Mesh:

Year:  2012        PMID: 22376091     DOI: 10.1111/j.1834-7819.2011.01665.x

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  14 in total

1.  Evaluation of low-contrast perceptibility in dental restorative materials under the influence of ambient light conditions.

Authors:  A D Cruz; I C Lobo; A L B Lemos; M F Aguiar
Journal:  Dentomaxillofac Radiol       Date:  2015-01-28       Impact factor: 2.419

2.  Evaluation of the radiation dose in the thyroid gland using different protective collars in panoramic imaging.

Authors:  Ladan Hafezi; S Marjan Arianezhad; Seyed Mahdi Hosseini Pooya
Journal:  Dentomaxillofac Radiol       Date:  2018-04-25       Impact factor: 2.419

3.  Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom.

Authors:  A Hidalgo; J Davies; K Horner; C Theodorakou
Journal:  Dentomaxillofac Radiol       Date:  2014-11-20       Impact factor: 2.419

Review 4.  Imaging of Radiation- and Medication-Related Osteonecrosis.

Authors:  Sanjay M Mallya; Sotirios Tetradis
Journal:  Radiol Clin North Am       Date:  2017-10-10       Impact factor: 2.303

5.  Kerma area product (KAP) and scatter measurements for intraoral X-ray machines using three different types of round collimation compared with rectangular beam limiter.

Authors:  Dennise Magill; Nhan James Huu Ngo; Marc A Felice; Mel Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2018-11-07       Impact factor: 2.419

6.  Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

Authors:  Lienard A Chang; Donald L Miller; Choonsik Lee; Dunstana R Melo; Daphnée Villoing; Vladimir Drozdovitch; Isabelle Thierry-Chef; Sarah J Winters; Michael Labrake; Charles F Myers; Hyeyeun Lim; Cari M Kitahara; Martha S Linet; Steven L Simon
Journal:  Health Phys       Date:  2017-12       Impact factor: 1.316

7.  Oblique lateral radiographs and bitewings; estimation of organ doses in head and neck region with Monte Carlo calculations.

Authors:  J K M Aps; J M Scott
Journal:  Dentomaxillofac Radiol       Date:  2014-05-16       Impact factor: 2.419

8.  Evaluation of a low-dose protocol for cone beam computed tomography of the temporomandibular joint - ethical and methodological considerations.

Authors:  Larissa de Oliveira Reis; Lucas P Lopes Rosado; Hugo Gaêta-Araujo; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2020-11-20       Impact factor: 2.419

9.  FDI policy statement on radiation safety in dentistry: adopted by the FDI General Assembly: 13 September 2014, New Delhi, India.

Authors: 
Journal:  Int Dent J       Date:  2014-12       Impact factor: 2.607

10.  Use of Reference Ear Plug to improve accuracy of lateral cephalograms generated from cone-beam computed tomography scans.

Authors:  Hyeon-Shik Hwang; Kyung-Min Lee; Gi-Soo Uhm; Jin-Hyoung Cho; James A McNamara
Journal:  Korean J Orthod       Date:  2013-04-25       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.