Oblique lateral radiographs and bitewings; estimation of organ doses in head and neck region with Monte Carlo calculations.

J K M Aps1, J M Scott.   

Abstract

OBJECTIVES: When bitewing radiographs are not possible (e.g. patients with special needs), oblique lateral radiographs may offer an alternative. The aims of this study were to assess the impact of horizontal projection angulation, focus-to-skin distance, exposure time and age of the patient on the equivalent radiation dose of several organs in the head and neck region by means of personal computer X-ray Monte Carlo (PCXMC) calculations and to assess the dose obtained from conventional bitewing radiographs.
METHODS: PCXMC v. 2.0 software (STUK(®), Helsinki, Finland) was used to estimate the equivalent radiation doses and the total effective dose. Three exposure times, five age categories, two focus-to-skin distances and eight horizontal geometric angulations were assumed. The organs involved were the thyroid gland, oesophagus, salivary glands, bone marrow, oral mucosa, skull, cervical spine and skin. A similar calculation was also performed for bitewings taken with a rectangular collimator. Results and conclusion Bitewings taken with rectangular collimation decrease the radiation burden of the patient to 50%, compared with circular collimation. In the oblique lateral radiographs, focus-to-skin distance, patient's age and beam collimation had a significant impact on the equivalent doses measured in this study. Exposure time had a significant impact on the equivalent doses of the salivary glands, oral mucosa, skull and skin. Horizontal angulations had a significant impact on the equivalent doses of the thyroid gland, bone marrow, oral mucosa, skull and cervical spine. The total effective radiation dose was significantly influenced by all parameters investigated in this study.

Entities:  

Keywords:  PCXMC; bitewings; oblique lateral radiographs; radiation dose

Mesh:

Year:  2014        PMID: 24834483      PMCID: PMC4141675          DOI: 10.1259/dmfr.20130419

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  22 in total

1.  An investigation into the use of bitewing radiography in children in Greater Glasgow.

Authors:  G K Taylor; L M D Macpherson
Journal:  Br Dent J       Date:  2004-05-08       Impact factor: 1.626

2.  NCRP report No. 145: New dental X-ray guidelines: their potential impact on your dental practice.

Authors:  Dale A Miles; Robert P Langlais
Journal:  Dent Today       Date:  2004-09

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Comparison of the efficacy and technical accuracy of different rectangular collimators for intraoral radiography.

Authors:  Wenjian Zhang; Kenneth Abramovitch; Walter Thames; Inga-Lill K Leon; Dan C Colosi; Arthur D Goren
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-05-22

5.  Evaluation of radiation exposure with Tru-Align intraoral rectangular collimation system using OSL dosimeters.

Authors:  Arthur D Goren; Michael J Bonvento; Thomas J Fernandez; Kenneth Abramovitch; Wenjian Zhang; Nadine Roe; Jared Seltzer; Mitchell Steinberg; Dan C Colosi
Journal:  N Y State Dent J       Date:  2011-03

6.  Dose evaluation of selective collimation effect in cephalography by measurement and Monte Carlo simulation.

Authors:  Boram Lee; Gwisoon Shin; Sunjung Kang; Boram Shin; Ilhong Back; Hyok Park; Changseo Park; Jeongwoo Lee; Wonho Lee; Jonghak Choi; Ryeonghwang Park; Youhyun Kim
Journal:  Radiat Prot Dosimetry       Date:  2011-02-17       Impact factor: 0.972

7.  A comparison between bitewing radiographs taken with rectangular and circular collimators in UK military dental practices: a retrospective study.

Authors:  L A Parrott; S Y Ng
Journal:  Dentomaxillofac Radiol       Date:  2011-02       Impact factor: 2.419

8.  Radiation exposure to children in intraoral dental radiology.

Authors:  H K Looe; A Pfaffenberger; N Chofor; F Eenboom; M Sering; A Rühmann; A Poplawski; K Willborn; B Poppe
Journal:  Radiat Prot Dosimetry       Date:  2006-06-17       Impact factor: 0.972

Review 9.  Dosimetry in diagnostic radiology.

Authors:  Ahmed Meghzifene; David R Dance; Donald McLean; Hans-Michael Kramer
Journal:  Eur J Radiol       Date:  2010-07-23       Impact factor: 3.528

Review 10.  Medical exposure to radiation and thyroid cancer.

Authors:  S J Schonfeld; C Lee; A Berrington de González
Journal:  Clin Oncol (R Coll Radiol)       Date:  2011-02-05       Impact factor: 4.126

View more
  3 in total

1.  Evidence on radiation dose reduction using rectangular collimation: a systematic review.

Authors:  Avdeesh Shetty; Fabiana T Almeida; Seema Ganatra; Anthea Senior; Camila Pacheco-Pereira
Journal:  Int Dent J       Date:  2018-06-29       Impact factor: 2.607

2.  Trends in Estimated Thyroid, Salivary Gland, Brain, and Eye Lens Doses From Intraoral Dental Radiography Over Seven Decades (1940 TO 2009).

Authors:  R C Fontana; E Pasqual; D L Miller; S L Simon; E Cardis; I Thierry-Chef
Journal:  Health Phys       Date:  2020-02       Impact factor: 2.922

3.  Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software.

Authors:  Eun-Kyung Kim; Won-Jeong Han; Jin-Woo Choi; Bulgan Battulga
Journal:  Imaging Sci Dent       Date:  2018-03-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.