Recently developed techniques such as the multiple acquisition with variable resonance image combination and slice encoding for metal artifact correction techniques have improved the ability of clinical magnetic resonance scanners to image near metal implants. These sequences are based on fast spin echo sequences which preclude detection of short T(2) tissues such as tendons, ligaments, and cortical bone. Ultrashort echo time sequences have the potential to detect signals from these tissues. In this study, we investigate the potential of combining ultrashort echo time with multiple acquisition with variable resonance image combination to image short T(2) musculoskeletal tissues adjacent to metallic implants. Different radio frequency excitation pulse types and spectral binning strategies were studied. We found that ultrashort echo time-multiple acquisition with variable resonance image combination sequences were able to significantly reduce typical artifacts near metal, as well as detect very short T(2) signals that are usually not visualized using clinical pulse sequences.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22374824     DOI: 10.1002/mrm.24219

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Automatic correction of dental artifacts in PET/MRI.

Authors:  Claes N Ladefoged; Flemming L Andersen; Sune H Keller; Thomas Beyer; Ian Law; Liselotte Højgaard; Sune Darkner; Francois Lauze
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-09

2.  PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging.

Authors:  Tim Hilgenfeld; Marcel Prager; Alexander Heil; Franz Sebastian Schwindling; Mathias Nittka; David Grodzki; Peter Rammelsberg; Martin Bendszus; Sabine Heiland
Journal:  Eur Radiol       Date:  2017-07-11       Impact factor: 5.315

3.  Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience.

Authors:  Edwin E G W Ter Voert; Patrick Veit-Haibach; Sangtae Ahn; Florian Wiesinger; M Mehdi Khalighi; Craig S Levin; Andrei H Iagaru; Greg Zaharchuk; Martin Huellner; Gaspar Delso
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-01-26       Impact factor: 9.236

Review 4.  Compressive osseointegration into a custom acetabular implant masquerading as tumor recurrence: a case report.

Authors:  Adam J Schwartz; Christopher P Beauchamp
Journal:  Clin Orthop Relat Res       Date:  2013-03       Impact factor: 4.176

5.  Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

Authors:  Curtis N Wiens; Nathan S Artz; Hyungseok Jang; Alan B McMillan; Kevin M Koch; Scott B Reeder
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

6.  Volumetric and multispectral DWI near metallic implants using a non-linear phase Carr-Purcell-Meiboom-Gill diffusion preparation.

Authors:  Philip K Lee; Daehyun Yoon; Jesse K Sandberg; Shreyas S Vasanawala; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2022-01-11       Impact factor: 4.668

Review 7.  State-of-the-art magnetic resonance imaging sequences for pediatric body imaging.

Authors:  Mareen Sarah Kraus; Ailish C Coblentz; Vibhas S Deshpande; Johannes M Peeters; Pedro M Itriago-Leon; Govind B Chavhan
Journal:  Pediatr Radiol       Date:  2022-10-18

8.  Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI.

Authors:  C Buchbender; V Hartung-Knemeyer; M Forsting; G Antoch; T A Heusner
Journal:  Br J Radiol       Date:  2013-05       Impact factor: 3.039

9.  In vitro assessment of knee MRI in the presence of metal implants comparing MAVRIC-SL and conventional fast spin echo sequences at 1.5 and 3 T field strength.

Authors:  Hans Liebl; Ursula Heilmeier; Sonia Lee; Lorenzo Nardo; Janina Patsch; Christopher Schuppert; Misung Han; Ina-Christine Rondak; Suchandrima Banerjee; Kevin Koch; Thomas M Link; Roland Krug
Journal:  J Magn Reson Imaging       Date:  2014-06-10       Impact factor: 4.813

10.  Dental artifacts in the head and neck region: implications for Dixon-based attenuation correction in PET/MR.

Authors:  Claes N Ladefoged; Adam E Hansen; Sune H Keller; Barbara M Fischer; Jacob H Rasmussen; Ian Law; Andreas Kjær; Liselotte Højgaard; Francois Lauze; Thomas Beyer; Flemming L Andersen
Journal:  EJNMMI Phys       Date:  2015-03-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.