Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population.

S Gang1, L Min, L Li, L Guo-Ying, X Lin, J Qun, Z Hua.   

Abstract

OBJECTIVES: The aim of this article was to prospectively evaluate the accuracy and radiation dose of 320-detector row dynamic volume CT (DVCT) for the detection of coronary artery disease (CAD) in a high-risk population.
METHODS: 60 patients with a high risk of CAD underwent DVCT without preceding heart rate control and also underwent invasive coronary angiography (ICA), which served as the standard reference.
RESULTS: On a per segment analysis, overall sensitivity was 95.3%, specificity was 97.6%, positive predictive value was 90.6%, negative predictive value was 98.8% and Youden index was 0.93. In both heart rate subgroups, diagnostic accuracy for the assessment of coronary artery stenosis was similar. The accuracy of the subgroup with an Agatston score ≥100 was lower than that for patients with an Agatston score <100. However, the difference between DVCT and ICA results was not significant (p=0.08). The mean estimated effective dose of CT was 12.5 ± 9.4 mSv. In those patients with heart rates less than 70 beats per minute (bpm), the mean radiation exposure of DVCT was 5.2 ± 0.9 mSv. The effective radiation dose was significantly lower than that of ICA (14.1 ± 5.9 mSv) (p<0.001). When the heart rate was >70 bpm, a significantly higher dose was delivered to patients with DVCT (22.6 ± 5.2 mSv, p<0.001) than with ICA (15.0 ± 5.3 mSv, p<0.001).
CONCLUSION: DVCT reliably provides high diagnostic accuracy without heart rate/rhythm control. However, from a dosimetric point of view, it is recommended that heart rate should be controlled to <70 bpm to decrease radiation dose.

Entities:  

Mesh:

Year:  2011        PMID: 21304010      PMCID: PMC3479877          DOI: 10.1259/bjr/90347290

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  39 in total

1.  Interventional cardiology in Europe 1995. Working Group Coronary Circulation of the European Society of Cardiology.

Authors:  S Windecker; W Maier-Rudolph; T Bonzel; G Heyndrickx; J M Lablanche; M C Morice; V Mühlberger; K L Neuhaus; F Piscione; M van den Brand; W Wijns; B Meier
Journal:  Eur Heart J       Date:  1999-04       Impact factor: 29.983

2.  Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses.

Authors:  A Knez; C R Becker; A Leber; B Ohnesorge; A Becker; C White; R Haberl; M F Reiser; G Steinbeck
Journal:  Am J Cardiol       Date:  2001-11-15       Impact factor: 2.778

3.  ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality.

Authors:  C Hong; C R Becker; A Huber; U J Schoepf; B Ohnesorge; A Knez; R Brüning; M F Reiser
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

4.  Complications of selective coronary arteriography by the Judkins technique and their prevention.

Authors:  A Shah; J Gnoj; V J Fisher
Journal:  Am Heart J       Date:  1975-09       Impact factor: 4.749

5.  Dealing with discreteness: making 'exact' confidence intervals for proportions, differences of proportions, and odds ratios more exact.

Authors:  A Agresti
Journal:  Stat Methods Med Res       Date:  2003-01       Impact factor: 3.021

6.  Ethical authorship and publishing.

Authors:  Andrew J S Coats
Journal:  Int J Cardiol       Date:  2008-11-28       Impact factor: 4.164

7.  Development and validation of a clinical score to estimate the probability of coronary artery disease in men and women presenting with suspected coronary disease.

Authors:  A P Morise; W J Haddad; D Beckner
Journal:  Am J Med       Date:  1997-04       Impact factor: 4.965

8.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

9.  Accuracy of thin-slice computed tomography in the detection of coronary stenoses.

Authors:  Eugenio Martuscelli; Andrea Romagnoli; Alessia D'Eliseo; Cinzia Razzini; Marco Tomassini; Massimiliano Sperandio; Giovanni Simonetti; Francesco Romeo
Journal:  Eur Heart J       Date:  2004-06       Impact factor: 29.983

10.  Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound.

Authors:  Alexander W Leber; Andreas Knez; Alexander Becker; Christoph Becker; Franz von Ziegler; Konstantin Nikolaou; Carsten Rist; Maximilian Reiser; Carl White; Gerhard Steinbeck; Peter Boekstegers
Journal:  J Am Coll Cardiol       Date:  2004-04-07       Impact factor: 24.094

View more
  9 in total

1.  320-detector row CT coronary angiography: effects of heart rate and heart rate variability on image quality, diagnostic accuracy and radiation exposure.

Authors:  G Sun; M Li; X-S Jiang; L Li; Z-H Peng; G-Y Li; L Xu
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

2.  Value of segmental coronary calcium score on diagnosis and interventional treatment of coronary lesions by 320-slice DVCT.

Authors:  Xiao-Yan Li; Guo-Ming Zhang; Hong-Ming Zhang; Gang Sun; Shu-Fang Han; Hong Tan; Yu-Qi Gao; Qun Jin; Yan-Min Li; Jie Fang
Journal:  Int J Clin Exp Med       Date:  2014-08-15

3.  Impact of heart rate on diagnostic accuracy of second generation 320-detector computed tomography coronary angiography.

Authors:  Nitesh Nerlekar; Brian S Ko; Arthur Nasis; James D Cameron; Michael Leung; Adam J Brown; Dennis T L Wong; Philip J Ngu; John M Troupis; Sujith K Seneviratne
Journal:  Cardiovasc Diagn Ther       Date:  2017-06

Review 4.  Diagnostic performance of coronary CT angiography for stenosis detection according to calcium score: systematic review and meta-analysis.

Authors:  Martijn A M den Dekker; Kristof de Smet; Geertruida H de Bock; Rene A Tio; Matthijs Oudkerk; Rozemarijn Vliegenthart
Journal:  Eur Radiol       Date:  2012-07-15       Impact factor: 5.315

5.  An investigation of correlation between left coronary bifurcation angle and hemodynamic changes in coronary stenosis by coronary computed tomography angiography-derived computational fluid dynamics.

Authors:  Zhonghua Sun; Thanapong Chaichana
Journal:  Quant Imaging Med Surg       Date:  2017-10

6.  Diagnostic value of four-dimensional CT angiography in arterial erectile dysfunction using 320-detector row dynamic volume CT.

Authors:  Cheng-Cheng Xu; Xin-Zhong Ruan; Yi-Fan Tang; Jiao-Hai Pan; Guo-Yao Wang; Qiu-Li Huang
Journal:  Biosci Rep       Date:  2017-08-21       Impact factor: 3.840

7.  Comprehensive assessment of cavernosography with 320-row dynamic volume CT versus conventional cavernosography in erectile dysfunction patients caused by venous leakage.

Authors:  Cheng-Cheng Xu; Yu-Ning Pan; Yi-Fan Tang; Jie Zhang; Guo-Yao Wang; Qiu-Li Huang
Journal:  Biosci Rep       Date:  2017-05-11       Impact factor: 3.840

Review 8.  Diagnostic accuracy of prospectively gated, 128-slice or greater CTCA at high heart rates: a systematic review and meta-analysis.

Authors:  Gordon T W Mander; Karen Dobeli; Caitlin Steffensen; Zachary Munn
Journal:  J Med Radiat Sci       Date:  2021-07-07

Review 9.  The diagnostic performance of coronary artery angiography with 64-MSCT and post 64-MSCT: systematic review and meta-analysis.

Authors:  Min Li; Xiang-Min Du; Zhi-Tao Jin; Zhao-Hui Peng; Juan Ding; Li Li
Journal:  PLoS One       Date:  2014-01-21       Impact factor: 3.240

  9 in total