Literature DB >> 16750636

Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer.

Alexander Makarov1, Eduard Denisov2, Oliver Lange2, Stevan Horning2.   

Abstract

Using a novel orbitrap mass spectrometer, the authors investigate the dynamic range over which accurate masses can be determined (extent of mass accuracy) for short duration experiments typical for LC/MS. A linear ion trap is used to selectively fill an intermediate ion storage device (C-trap) with ions of interest, following which the ensemble of ions is injected into an orbitrap mass analyzer and analyzed using image current detection and fast Fourier transformation. Using this technique, it is possible to generate ion populations with intraspectrum intensity ranges up to 10(4). All measurements (including ion accumulation and image current detection) were performed in less than 1 s at a resolving power of 30,000. It was shown that 5-ppm mass accuracy of the orbitrap mass analyzer is reached with >95% probability at a dynamic range of more than 5000, which is at least an order of magnitude higher than typical values for time-of-flight instruments. Due to the high resolving power of the orbitrap, accurate mass of an ion could be determined when the signal was reliably distinguished from noise (S/Np-p)>2...3).

Year:  2006        PMID: 16750636     DOI: 10.1016/j.jasms.2006.03.006

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  11 in total

1.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis

Authors: 
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

2.  Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer.

Authors:  K F Blom
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

3.  Mass measurement errors caused by 'local" frequency perturbations in FTICR mass spectrometry.

Authors:  Christophe Masselon; Aleksey V Tolmachev; Gordon A Anderson; Richard Harkewicz; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-01       Impact factor: 3.109

4.  A two-dimensional quadrupole ion trap mass spectrometer.

Authors:  Jae C Schwartz; Michael W Senko; John E P Syka
Journal:  J Am Soc Mass Spectrom       Date:  2002-06       Impact factor: 3.109

5.  Exact mass measurement on an electrospray ionization time-of-flight mass spectrometer: error distribution and selective averaging.

Authors:  Jiejun Wu; Heather McAllister
Journal:  J Mass Spectrom       Date:  2003-10       Impact factor: 1.982

6.  Novel linear quadrupole ion trap/FT mass spectrometer: performance characterization and use in the comparative analysis of histone H3 post-translational modifications.

Authors:  John E P Syka; Jarrod A Marto; Dina L Bai; Stevan Horning; Michael W Senko; Jae C Schwartz; Beatrix Ueberheide; Benjamin Garcia; Scott Busby; Tara Muratore; Jeffrey Shabanowitz; Donald F Hunt
Journal:  J Proteome Res       Date:  2004 May-Jun       Impact factor: 4.466

7.  A fully automated method for accurate mass determination using high-performance liquid chromatography with a quadrupole/orthogonal acceleration time-of-flight mass spectrometer.

Authors:  Maristella Colombo; Federico Riccardi Sirtori; Vincenzo Rizzo
Journal:  Rapid Commun Mass Spectrom       Date:  2004       Impact factor: 2.419

8.  Parts per million mass accuracy on an Orbitrap mass spectrometer via lock mass injection into a C-trap.

Authors:  Jesper V Olsen; Lyris M F de Godoy; Guoqing Li; Boris Macek; Peter Mortensen; Reinhold Pesch; Alexander Makarov; Oliver Lange; Stevan Horning; Matthias Mann
Journal:  Mol Cell Proteomics       Date:  2005-10-24       Impact factor: 5.911

9.  Routine Part-per-Million Mass Accuracy for High- Mass Ions:  Space-Charge Effects in MALDI FT-ICR.

Authors:  M L Easterling; T H Mize; I J Amster
Journal:  Anal Chem       Date:  1999-02-01       Impact factor: 6.986

10.  Space charge effects in Fourier transform mass spectrometry. Mass calibration.

Authors:  E B Ledford; D L Rempel; M L Gross
Journal:  Anal Chem       Date:  1984-12       Impact factor: 6.986

View more
  91 in total

1.  Improved mass defect model for theoretical tryptic peptides.

Authors:  Indranil Mitra; Alexey V Nefedov; Allan R Brasier; Rovshan G Sadygov
Journal:  Anal Chem       Date:  2012-03-07       Impact factor: 6.986

2.  Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: simulation approach.

Authors:  Andriy Kharchenko; Gleb Vladimirov; Ron M A Heeren; Eugene N Nikolaev
Journal:  J Am Soc Mass Spectrom       Date:  2012-02-22       Impact factor: 3.109

3.  Calibration function for the Orbitrap FTMS accounting for the space charge effect.

Authors:  Mikhail V Gorshkov; David M Good; Yaroslav Lyutvinskiy; Hongqian Yang; Roman A Zubarev
Journal:  J Am Soc Mass Spectrom       Date:  2010-07-07       Impact factor: 3.109

Review 4.  Systems biology in immunology: a computational modeling perspective.

Authors:  Ronald N Germain; Martin Meier-Schellersheim; Aleksandra Nita-Lazar; Iain D C Fraser
Journal:  Annu Rev Immunol       Date:  2011       Impact factor: 28.527

5.  Spectral accuracy and sulfur counting capabilities of the LTQ-FT-ICR and the LTQ-Orbitrap XL for small molecule analysis.

Authors:  Samantha L Blake; S Hunter Walker; David C Muddiman; David Hinks; Keith R Beck
Journal:  J Am Soc Mass Spectrom       Date:  2011-09-21       Impact factor: 3.109

6.  Paper-Based Electrochemical Cell Coupled to Mass Spectrometry.

Authors:  Yao-Min Liu; Richard H Perry
Journal:  J Am Soc Mass Spectrom       Date:  2015-08-27       Impact factor: 3.109

7.  Performance metrics for evaluating system suitability in liquid chromatography--Mass spectrometry peptide mass mapping of protein therapeutics and monoclonal antibodies.

Authors:  Mowei Zhou; Ashley C Gucinski; Michael T Boyne
Journal:  MAbs       Date:  2015-07-28       Impact factor: 5.857

8.  Toward the complete characterization of host cell proteins in biotherapeutics via affinity depletions, LC-MS/MS, and multivariate analysis.

Authors:  James A Madsen; Victor Farutin; Theresa Carbeau; Steve Wudyka; Yan Yin; Stephen Smith; James Anderson; Ishan Capila
Journal:  MAbs       Date:  2015-08-20       Impact factor: 5.857

9.  Identification of potential serum biomarkers for rheumatoid arthritis by high-resolution quantitative proteomic analysis.

Authors:  Yongjing Cheng; Yuling Chen; Xiaolin Sun; Yuhui Li; Cibo Huang; Haiteng Deng; Zhanguo Li
Journal:  Inflammation       Date:  2014-10       Impact factor: 4.092

10.  MassMatrix: a database search program for rapid characterization of proteins and peptides from tandem mass spectrometry data.

Authors:  Hua Xu; Michael A Freitas
Journal:  Proteomics       Date:  2009-03       Impact factor: 3.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.