An automatic method for renal cortex segmentation on CT images: evaluation on kidney donors.

Xinjian Chen1, Ronald M Summers, Monique Cho, Ulas Bagci, Jianhua Yao.   

Abstract

RATIONALE AND
OBJECTIVES: The aims of this study were to develop and validate an automated method to segment the renal cortex on contrast-enhanced abdominal computed tomographic images from kidney donors and to track cortex volume change after donation.
MATERIALS AND METHODS: A three-dimensional fully automated renal cortex segmentation method was developed and validated on 37 arterial phase computed tomographic data sets (27 patients, 10 of whom underwent two computed tomographic scans before and after nephrectomy) using leave-one-out strategy. Two expert interpreters manually segmented the cortex slice by slice, and linear regression analysis and Bland-Altman plots were used to compare automated and manual segmentation. The true-positive and false-positive volume fractions were also calculated to evaluate the accuracy of the proposed method. Cortex volume changes in 10 subjects were also calculated.
RESULTS: The linear regression analysis results showed that the automated and manual segmentation methods had strong correlations, with Pearson's correlations of 0.9529, 0.9309, 0.9283, and 0.9124 between intraobserver variation, interobserver variation, automated and user 1, and automated and user 2, respectively (P < .001 for all analyses). The Bland-Altman plots for cortex segmentation also showed that the automated and manual methods had agreeable segmentation. The mean volume increase of the cortex for the 10 subjects was 35.1 ± 13.2% (P < .01 by paired t test). The overall true-positive and false-positive volume fractions for cortex segmentation were 90.15 ± 3.11% and 0.85 ± 0.05%. With the proposed automated method, the time for cortex segmentation was reduced from 20 minutes for manual segmentation to 2 minutes.
CONCLUSIONS: The proposed method was accurate and efficient and can replace the current subjective and time-consuming manual procedure. The computer measurement confirms the volume of renal cortex increases after kidney donation. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22341876      PMCID: PMC3319195          DOI: 10.1016/j.acra.2012.01.005

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  24 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Renal cortex segmentation using optimal surface search with novel graph construction.

Authors:  Xiuli Li; Xinjian Chen; Jianhua Yao; Xing Zhang; Jie Tian
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

3.  An experimental comparison of min-cut/max-flow algorithms for energy minimization in vision.

Authors:  Yuri Boykov; Vladimir Kolmogorov
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2004-09       Impact factor: 6.226

4.  Computer-aided kidney segmentation on abdominal CT images.

Authors:  Daw-Tung Lin; Chung-Chih Lei; Siu-Wan Hung
Journal:  IEEE Trans Inf Technol Biomed       Date:  2006-01

5.  Assessment of 100 live potential renal donors for laparoscopic nephrectomy with multi-detector row helical CT.

Authors:  Andrew Holden; Andrew Smith; Paul Dukes; Helen Pilmore; Motohiko Yasutomi
Journal:  Radiology       Date:  2005-12       Impact factor: 11.105

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Multi-detector row CT in evaluation of 94 living renal donors by readers with varied experience.

Authors:  Dushyant V Sahani; Neeraj Rastogi; Alan C Greenfield; Sanjeeva P Kalva; Dicken Ko; Sanjay Saini; Gordon Harris; Peter R Mueller
Journal:  Radiology       Date:  2005-04-15       Impact factor: 11.105

8.  Potential renal transplant donors: evaluation with gadolinium-enhanced MR angiography and MR urography.

Authors:  R N Low; A G Martinez; S M Steinberg; G D Alzate; K E Kortman; B B Bower; W J Dwyer; S K Prince
Journal:  Radiology       Date:  1998-04       Impact factor: 11.105

9.  Functional renal volume: quantitative analysis at gadolinium-enhanced MR angiography--feasibility study in healthy potential kidney donors.

Authors:  Sjoerd W van den Dool; Martin N Wasser; Johan W de Fijter; Jan Hoekstra; Rob J van der Geest
Journal:  Radiology       Date:  2005-07       Impact factor: 11.105

10.  Living donor kidneys: usefulness of multi-detector row CT for comprehensive evaluation.

Authors:  Jeong-Kon Kim; Soo-Youn Park; Heon-Joon Kim; Chung-Soo Kim; Han-Jong Ahn; Tae-Young Ahn; Kyoung-Sik Cho
Journal:  Radiology       Date:  2003-10-30       Impact factor: 11.105

View more
  8 in total

1.  Automated segmentation of the injured kidney due to abdominal trauma.

Authors:  Gokalp Tulum; Uygar Teomete; Ferhat Cuce; Tuncer Ergin; Murathan Koksal; Ozgur Dandin; Onur Osman
Journal:  J Med Syst       Date:  2019-11-24       Impact factor: 4.460

2.  Abdominal multi-organ segmentation from CT images using conditional shape-location and unsupervised intensity priors.

Authors:  Toshiyuki Okada; Marius George Linguraru; Masatoshi Hori; Ronald M Summers; Noriyuki Tomiyama; Yoshinobu Sato
Journal:  Med Image Anal       Date:  2015-07-04       Impact factor: 8.545

Review 3.  Progress in Fully Automated Abdominal CT Interpretation.

Authors:  Ronald M Summers
Journal:  AJR Am J Roentgenol       Date:  2016-04-21       Impact factor: 3.959

4.  A Novel Extension to Fuzzy Connectivity for Body Composition Analysis: Applications in Thigh, Brain, and Whole Body Tissue Segmentation.

Authors:  Ismail Irmakci; Sarfaraz Hussein; Aydogan Savran; Rita R Kalyani; David Reiter; Chee W Chia; Kenneth W Fishbein; Richard G Spencer; Luigi Ferrucci; Ulas Bagci
Journal:  IEEE Trans Biomed Eng       Date:  2018-08-30       Impact factor: 4.538

5.  Automated Segmentation of Kidney Cortex and Medulla in CT Images: A Multisite Evaluation Study.

Authors:  Panagiotis Korfiatis; Aleksandar Denic; Marie E Edwards; Adriana V Gregory; Darryl E Wright; Aidan Mullan; Joshua Augustine; Andrew D Rule; Timothy L Kline
Journal:  J Am Soc Nephrol       Date:  2021-12-07       Impact factor: 10.121

6.  X-ray phase-contrast tomography of renal ischemia-reperfusion damage.

Authors:  Astrid Velroyen; Martin Bech; Irene Zanette; Jolanda Schwarz; Alexander Rack; Christiane Tympner; Tanja Herrler; Claudia Staab-Weijnitz; Margarita Braunagel; Maximilian Reiser; Fabian Bamberg; Franz Pfeiffer; Mike Notohamiprodjo
Journal:  PLoS One       Date:  2014-10-09       Impact factor: 3.240

7.  Effect of ruptured cavitated bubble cluster on the extent of the cell deformation by ultrasound.

Authors:  Peilin Cao; Changchun Hao; Binbin Li; Hao Jiang; Yongfeng Liu
Journal:  Ultrason Sonochem       Date:  2021-11-23       Impact factor: 7.491

8.  3D marker-controlled watershed for kidney segmentation in clinical CT exams.

Authors:  Wojciech Wieclawek
Journal:  Biomed Eng Online       Date:  2018-02-27       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.