Literature DB >> 2233574

Single-exposure dual-energy computed radiography.

B K Stewart1, H K Huang.   

Abstract

This paper focuses on analysis and development of a single-exposure dual-energy digital radiographic method using computed radiography (Fuji FCR-101 storage phosphor system). A detector sandwich consisting of storage phosphor imaging plates and an interdetector filter is used. The goal of this process is to provide a simple dual-energy method using typical plane-projection radiographic equipment and techniques. This approach exploits the transparency of the storage phosphor plates, using radiographic information that would be otherwise lost, to provide energy selective information essentially as a by-product of the radiographic examination. In order to effectively make use of the large dynamic range of the storage phosphor imaging plates (10,000:1), a computed radiography image reading mode of fixed analog-to-digital converter gain and variable photomultiplier sensitivity provides image data which can be related to relative incident exposure for export to the decomposition algorithm. Scatter rejection requirements necessitated crossed 12:1 grids for a field size of 36 x 36 cm. Optimal technique parameters obtained from computer simulation through minimization of the aluminum and Plexiglas equivalent image uncertainty under conditions of constant absorbed does resulted as: 100 kVp using a 0.15-mm-thick tin (Sn) interdetector filter for the lung field. This yields a surface exposure of 23 mR and a surface absorbed dose of 0.26 mGy for a 23-cm-thick chest. Clinical application in evaluation of the solitary pulmonary nodule is discussed, along with an image set demonstrating this application.

Entities:  

Mesh:

Year:  1990        PMID: 2233574     DOI: 10.1118/1.596479

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Comparison of three different techniques for dual-energy subtraction imaging in digital radiography: a signal-to-noise analysis.

Authors:  C C Shaw; D Gur
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

2.  Computed radiography dual energy subtraction: performance evaluation when detecting low-contrast lung nodules in an anthropomorphic phantom.

Authors:  C Kimme-Smith; D L Davis; M McNitt-Gray; J Goldin; E Hart; P Batra; T D Johnson
Journal:  J Digit Imaging       Date:  1999-02       Impact factor: 4.056

3.  Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice.

Authors:  Zsolt Szucs-Farkas; Michael A Patak; Seyran Yuksel-Hatz; Thomas Ruder; Peter Vock
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

4.  Comparison of three tissue composition measurement techniques using digital mammograms--a signal-to-noise study.

Authors:  D S Breitenstein; C C Shaw
Journal:  J Digit Imaging       Date:  1998-08       Impact factor: 4.056

5.  Biplane correlation imaging: a feasibility study based on phantom and human data.

Authors:  Ehsan Samei; Nariman Majdi-Nasab; James T Dobbins; H Page McAdams
Journal:  J Digit Imaging       Date:  2012-02       Impact factor: 4.056

6.  Separation of bones from soft tissue in chest radiographs: Anatomy-specific orientation-frequency-specific deep neural network convolution.

Authors:  Amin Zarshenas; Junchi Liu; Paul Forti; Kenji Suzuki
Journal:  Med Phys       Date:  2019-03-28       Impact factor: 4.071

7.  Improvement of detection in computed radiography by new single-exposure dual-energy subtraction.

Authors:  W Ito; K Shimura; N Nakajima; M Ishida; H Kato
Journal:  J Digit Imaging       Date:  1993-02       Impact factor: 4.056

Review 8.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Joel G Fletcher
Journal:  Radiology       Date:  2015-09       Impact factor: 11.105

9.  Pixel-based machine learning in medical imaging.

Authors:  Kenji Suzuki
Journal:  Int J Biomed Imaging       Date:  2012-02-28
  9 in total