Pulse oximetry used for documenting oxygen saturation and right-to-left shunting immediately after birth.

P Meier-Stauss1, H U Bucher, R Hürlimann, V König, R Huch.   

Abstract

The objective of this study was to investigate the clinical applicability of pulse oximetry to measure haemoglobin oxygen saturation and heart rate in the first 20 min of life and to analyse the effect of pre- or post-ductal (hand, respectively, foot) fixation of sensors on oxygen saturation. Measurements were carried out on 53 newborn infants selected at random after delivery by caesarean section. Signal detection occurred significantly faster from the hand (50% after 1.3 min, 90% after 4 min) than from the foot (50% after 3.1 min, 90% after 9 min). Both fixation sites showed equally great sensitivity to motion. The heart rates from pulse oximetry recordings were up to 30% lower than those from ECG recordings. Saturation values from the hand were nearly always higher than those from the foot (median difference in the 5th min was 10%; between the 5th and 10th min it was 7%; no significant difference occurred after the 17th min). We conclude that pulse oximetry can be used for documenting oxygenation and right-to-left shunting in newborn infants during the first minutes of life in spite of limitations due to incomplete pulse wave detection and artifacts.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2226570     DOI: 10.1007/bf02072072

Source DB:  PubMed          Journal:  Eur J Pediatr        ISSN: 0340-6199            Impact factor:   3.183


  13 in total

1.  Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants.

Authors:  M S Jennis; J L Peabody
Journal:  Pediatrics       Date:  1987-04       Impact factor: 7.124

2.  Is the Apgar score outmoded?

Authors: 
Journal:  Lancet       Date:  1989-03-18       Impact factor: 79.321

3.  Neonatal pulse oximetry: accuracy and reliability.

Authors:  W W Hay; J M Brockway; M Eyzaguirre
Journal:  Pediatrics       Date:  1989-05       Impact factor: 7.124

4.  Monitoring arterial oxygen saturation in the neonate.

Authors:  R Deckardt; K T Schneider; H Graeff
Journal:  J Perinat Med       Date:  1987       Impact factor: 1.901

5.  Changes in arterial oxygen saturation immediately after birth in the human neonate.

Authors:  A P Harris; M J Sendak; R T Donham
Journal:  J Pediatr       Date:  1986-07       Impact factor: 4.406

6.  Oxygen method for calculation of right to left shunt: new application in presence of right to left shunting through the ductus arteriosus.

Authors:  W M Gersony; G V Duc; R B Dell; J C Sinclair
Journal:  Cardiovasc Res       Date:  1972-07       Impact factor: 10.787

7.  Pulse oximeter and transcutaneous arterial oxygen measurements in neonatal and paediatric intensive care.

Authors:  D P Southall; S Bignall; V A Stebbens; J R Alexander; R P Rivers; T Lissauer
Journal:  Arch Dis Child       Date:  1987-09       Impact factor: 3.791

8.  Continuous neonatal evaluation in the delivery room by pulse oximetry.

Authors:  J T House; R R Schultetus; N Gravenstein
Journal:  J Clin Monit       Date:  1987-04

9.  [Reliability and limitations of pulse oximetry in corrective cyanotic heart surgery].

Authors:  P Meier-Stauss; E R Schmid; B M Weiss; V König; R Huch
Journal:  Anaesthesist       Date:  1989-06       Impact factor: 1.041

10.  Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension.

Authors:  S Fanconi; P Doherty; J F Edmonds; G A Barker; D J Bohn
Journal:  J Pediatr       Date:  1985-09       Impact factor: 4.406

View more
  9 in total

1.  Simultaneous measurement of preductal and postductal oxygen saturation by pulse oximetry in hyaline membrane disease.

Authors:  P D Macdonald; V Y Yu
Journal:  Arch Dis Child       Date:  1992-10       Impact factor: 3.791

Review 2.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

Review 3.  Pulse oximetry for monitoring infants in the delivery room: a review.

Authors:  J A Dawson; P G Davis; C P F O'Donnell; C O F Kamlin; C J Morley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-01       Impact factor: 5.747

4.  Percentiles of oxygen saturations in healthy term newborns in the first minutes of life.

Authors:  Emel Altuncu; Eren Ozek; Hülya Bilgen; Ahmet Topuzoglu; Sultan Kavuncuoglu
Journal:  Eur J Pediatr       Date:  2007-07-20       Impact factor: 3.183

Review 5.  [Resuscitation of newborn infants].

Authors:  T M Berger; S Pilgrim
Journal:  Anaesthesist       Date:  2009-01       Impact factor: 1.041

6.  Reflectance pulse oximetry at the forehead of newborns: the influence of varying pressure on the probe.

Authors:  A C Dassel; R Graaff; A Meijer; W G Zijlstra; J G Aarnoudse
Journal:  J Clin Monit       Date:  1996-11

7.  Pulmonary gas exchange during facemask ventilation immediately after birth.

Authors:  C Palme-Kilander; R Tunell
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

8.  Pulmonary gas exchange immediately after birth in spontaneously breathing infants.

Authors:  C Palme-Kilander; R Tunell; Y Chiwei
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

9.  Marked variation in newborn resuscitation practice: a national survey in the UK.

Authors:  Chantelle Mann; Carole Ward; Mark Grubb; Barrie Hayes-Gill; John Crowe; Neil Marlow; Don Sharkey
Journal:  Resuscitation       Date:  2012-01-12       Impact factor: 5.262

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.