Literature DB >> 2434911

Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants.

M S Jennis, J L Peabody.   

Abstract

Continuous monitoring of oxygenation in sick newborns is vitally important. However, transcutaneous PO2 measurements have a number of limitations. Therefore, we report the use of the pulse oximeter for arterial oxygen saturation (SaO2) determination in 26 infants (birth weights 725 to 4,000 g, gestational ages 24 to 40 weeks, and postnatal ages one to 49 days). Fetal hemoglobin determinations were made on all infants and were repeated following transfusion. SaO2 readings from the pulse oximeter were compared with the SaO2 measured in vitro on simultaneously obtained arterial blood samples. The linear regression equation for 177 paired measurements was: y = 0.7x + 27.2; r = .9. However, the differences between measured SaO2 and the pulse oximeter SaO2 were significantly greater in samples with greater than 50% fetal hemoglobin when compared with samples with less than 25% fetal hemoglobin (P less than .001). The pulse oximeter was easy to use, recorded trends in oxygenation instantaneously, and was not associated with skin injury. We conclude that pulse oximetry is a reliable technique for the continuous, noninvasive monitoring of oxygenation in newborn infants.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 2434911

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  14 in total

1.  Pulse oximetry used for documenting oxygen saturation and right-to-left shunting immediately after birth.

Authors:  P Meier-Stauss; H U Bucher; R Hürlimann; V König; R Huch
Journal:  Eur J Pediatr       Date:  1990-09       Impact factor: 3.183

Review 2.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

3.  Non-invasive oxygen saturation monitoring in neonates.

Authors:  K Dziedzic; D Vidyasagar
Journal:  Indian J Pediatr       Date:  1989 Sep-Oct       Impact factor: 1.967

4.  Pulse oximetry reference values at high altitude.

Authors:  J M Lozano; O R Duque; T Buitrago; S Behaine
Journal:  Arch Dis Child       Date:  1992-03       Impact factor: 3.791

5.  Accuracy of pulse oximeters in estimating heart rate at rest and during exercise.

Authors:  Y Iyriboz; S Powers; J Morrow; D Ayers; G Landry
Journal:  Br J Sports Med       Date:  1991-09       Impact factor: 13.800

6.  Suctioning Newborns: A practical guide to when and how.

Authors:  S Blatz; B A Paes; D J Kraftcheck
Journal:  Can Fam Physician       Date:  1992-08       Impact factor: 3.275

Review 7.  Uses and abuses of pulse oximetry.

Authors:  J T Moyle
Journal:  Arch Dis Child       Date:  1996-01       Impact factor: 3.791

8.  Oxygen saturation during the first 24 hours of life.

Authors:  L M O'Brien; V A Stebbens; C F Poets; E G Heycock; D P Southall
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-07       Impact factor: 5.747

9.  A Two Year Experience in Continuous Positive Airway Pressure Ventilation Using Nasal Prongs and Pulse Oximetry.

Authors:  R K Malik; R K Gupta
Journal:  Med J Armed Forces India       Date:  2011-07-21

Review 10.  Clinical Approach to a Neonate with Cyanosis.

Authors:  Saurabh Kumar Gupta
Journal:  Indian J Pediatr       Date:  2015-09-19       Impact factor: 1.967

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.