Literature DB >> 2225641

The effect of femoral component position on patellar tracking after total knee arthroplasty.

D D Rhoads1, P C Noble, J D Reuben, O M Mahoney, H S Tullos.   

Abstract

In a laboratory study, seven fresh anatomic knee specimens were evaluated to define the three-dimensional motions of the patella before and after total knee arthroplasty (TKA) with the AMK knee. The patella was displaced medially by an average of 4 mm and tilted medially by an average of 4 degrees after standard TKA. Medial translation or internal rotation of the femoral component further displaced and tilted the patella medially, but lateral translation or external rotation of the femoral component produced less predictable changes in patellar tracking. The patterns of patellar tracking after external rotation of the femoral component came closer to reproducing those of the intact knee than any other femoral component position. The high lateral ridge on the femoral component effectively prevents patellar dislocation but may produce abnormally high stresses on the patellar implant, especially if the implant is medially displaced or internally rotated. This could lead to accelerated wear or loosening of the patellar component.

Entities:  

Mesh:

Year:  1990        PMID: 2225641

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

2.  Femoral component rotation in patients with leg axis deviation.

Authors:  Tim Classen; Stefan Landgraeber; Alexander Wegner; Ralf-Dietrich Müller; Marius von Knoch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-12-15       Impact factor: 4.342

3.  Native femoral sulcus as a guide for the position of the femoral component in primary total knee arthroplasty: a prospective comparative study of 420 knees.

Authors:  Fang-Yao Chiu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-08-26       Impact factor: 4.342

4.  Asymmetrical total knee arthroplasty does not improve patella tracking: a study without patella resurfacing.

Authors:  Marco Barink; Huub Meijerink; Nico Verdonschot; Albert van Kampen; Maarten de Waal Malefijt
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-15       Impact factor: 4.342

5.  The femoral sulcus in total knee arthroplasty.

Authors:  Krishna Lingaraj; John Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-01-31       Impact factor: 4.342

6.  Determining femoral component position using CAS and measured resection.

Authors:  James Benjamin
Journal:  Clin Orthop Relat Res       Date:  2008-08-15       Impact factor: 4.176

7.  Is referencing the posterior condyles sufficient to achieve a rectangular flexion gap in total knee arthroplasty?

Authors:  Christoph Schnurr; Jochen Nessler; Dietmar Pierre König
Journal:  Int Orthop       Date:  2008-10-28       Impact factor: 3.075

8.  Combining different rotational alignment axes with navigation may reduce the need for lateral retinacular release in total knee arthroplasty.

Authors:  Gianluca Cinotti; Francesca R Ripani; Pasquale Sessa; Giuseppe Giannicola
Journal:  Int Orthop       Date:  2012-05-16       Impact factor: 3.075

Review 9.  No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA.

Authors:  Huichao Fu; Jiaxing Wang; Shenyuan Zhou; Tao Cheng; Wen Zhang; Qi Wang; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

10.  Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Jan Victor; Jan Dujardin; Hilde Vandenneucker; Nele Arnout; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.