Literature DB >> 22588689

Combining different rotational alignment axes with navigation may reduce the need for lateral retinacular release in total knee arthroplasty.

Gianluca Cinotti1, Francesca R Ripani, Pasquale Sessa, Giuseppe Giannicola.   

Abstract

PURPOSE: The aim of the study was to compare femoropatellar alignment and the incidence of lateral retinacular release (LRR) in total knee arthroplasty (TKA) in which the rotational alignment of the femoral component was determined using a combination of different rotational alignment axes and navigation or a single reference axis in the standard procedure.
METHODS: We assessed 66 patients undergoing TKA in whom the rotation of the femoral component was determined on the posterior condylar axis in standard procedures (group A) and 65 patients in whom it was determined by combining the posterior condylar axis, anteroposterior axis and epicondylar axis in navigated procedures (group B). The mean age was 68 and 69 years in groups A and B, respectively. Patellar tracking was assessed after deflation of the tourniquet and LRR performed in the presence of maltracking. Visual analogue scale (VAS), Knee Society Score (KSS), Lonner patellar score and patellar tilt were recorded.
RESULTS: LRR was carried out in 18 cases (27 %) in group A and in four (6 %) in group B (p = 0.003). The KSS and VAS were improved significantly compared to the preoperative status, but with no significant differences between the two groups. The patellar score showed a greater improvement in the navigated compared to the standard group at the four week follow-up. Patella tilt improved significantly in both groups. The complication rate was similar in the two groups.
CONCLUSIONS: Combining different rotational alignment axes with navigation significantly reduces patellar maltracking and the need for LRR compared to the standard procedure in which the posterior condylar axis is used as single anatomical reference.

Entities:  

Mesh:

Year:  2012        PMID: 22588689      PMCID: PMC3535050          DOI: 10.1007/s00264-012-1523-8

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  30 in total

1.  Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri
Journal:  Acta Orthop Scand       Date:  2004-02

2.  The effect of femoral component position on patellar tracking after total knee arthroplasty.

Authors:  D D Rhoads; P C Noble; J D Reuben; O M Mahoney; H S Tullos
Journal:  Clin Orthop Relat Res       Date:  1990-11       Impact factor: 4.176

3.  Flexion space configuration in total knee arthroplasty.

Authors:  R S Laskin
Journal:  J Arthroplasty       Date:  1995-10       Impact factor: 4.757

4.  The relationship of lateral releases to patella viability in total knee arthroplasty.

Authors:  G Scuderi; S C Scharf; L P Meltzer; W N Scott
Journal:  J Arthroplasty       Date:  1987       Impact factor: 4.757

5.  Contemporary femoral designs in total knee arthroplasty: effects on the patello-femoral congruence.

Authors:  Pier Francesco Indelli; Massimiliano Marcucci; Donatella Cariello; Paolo Poli; Massimo Innocenti
Journal:  Int Orthop       Date:  2011-12-28       Impact factor: 3.075

6.  The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty.

Authors:  L A Whiteside; J Arima
Journal:  Clin Orthop Relat Res       Date:  1995-12       Impact factor: 4.176

7.  The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens.

Authors:  Y S Anouchi; L A Whiteside; A D Kaiser; M T Milliano
Journal:  Clin Orthop Relat Res       Date:  1993-02       Impact factor: 4.176

8.  Patellar prosthesis positioning in total knee arthroplasty. A roentgenographic study.

Authors:  L S Gomes; J E Bechtold; R B Gustilo
Journal:  Clin Orthop Relat Res       Date:  1988-11       Impact factor: 4.176

9.  Implications of reference axes used for rotational alignment of the femoral component in primary and revision knee arthroplasty.

Authors:  J P Mantas; R D Bloebaum; J G Skedros; A A Hofmann
Journal:  J Arthroplasty       Date:  1992-12       Impact factor: 4.757

10.  Patellofemoral complications following total knee arthroplasty. Effect of a lateral release and sacrifice of the superior lateral geniculate artery.

Authors:  M A Ritter; S A Herbst; E M Keating; P M Faris; J B Meding
Journal:  J Arthroplasty       Date:  1996-06       Impact factor: 4.757

View more
  8 in total

1.  Varus-valgus stress radiograph as a predictor for extensive medial release in total knee arthroplasty.

Authors:  Ji Hyun Ahn; Sung Hyun Lee; Tae Yeong Yang
Journal:  Int Orthop       Date:  2015-10-15       Impact factor: 3.075

2.  Is it possible to re-establish pre-operative patellar kinematics using a ligament-balanced technique in total knee arthroplasty? A cadaveric investigation.

Authors:  Armin Keshmiri; Hans Springorum; Clemens Baier; Florian Zeman; Joachim Grifka; Günther Maderbacher
Journal:  Int Orthop       Date:  2014-08-27       Impact factor: 3.075

3.  Cutting and implanting errors in minimally invasive total knee arthroplasty using a navigation system.

Authors:  Masahiro Hasegawa; Kakunoshin Yoshida; Hiroki Wakabayashi; Akihiro Sudo
Journal:  Int Orthop       Date:  2012-10-28       Impact factor: 3.075

4.  The combined Whiteside's and posterior condylar line as a reliable reference to describe axial distal femoral anatomy in patient-specific instrument planning.

Authors:  Frederic Paternostre; Pierre-Emmanuel Schwab; Emmanuel Thienpont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-21       Impact factor: 4.342

5.  Does computer-assisted total knee arthroplasty improve the overall component position and patient function?

Authors:  Charlotte L Allen; Gary J Hooper; Byron J Oram; J Elizabeth Wells
Journal:  Int Orthop       Date:  2013-07-11       Impact factor: 3.075

6.  Referencing the sulcus line of the trochlear groove and removing intraoperative parallax errors improve femoral component rotation in total knee arthroplasty.

Authors:  Simon Talbot; Pandelis Dimitriou; Michael Mullen; John Bartlett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-06-07       Impact factor: 4.342

7.  Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry.

Authors:  Tat Woon Chao; Liam Geraghty; Pandelis Dimitriou; Simon Talbot
Journal:  J Orthop Surg Res       Date:  2017-05-12       Impact factor: 2.359

8.  Computed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study.

Authors:  Stefan W Kreuzer; Amir Pourmoghaddam; Kevin J Leffers; Clint W Johnson; Marius Dettmer
Journal:  Adv Orthop       Date:  2016-01-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.