Literature DB >> 22231644

Dual- versus single-coil implantable defibrillator leads: review of the literature.

Jörg Neuzner1, Jörg Carlsson.   

Abstract

The preferred use of dual-coil implantable defibrillator lead systems in current implantable defibrillator therapy is likely based on data showing statistically lower defibrillation thresholds with dual-coil defibrillator lead systems. The following review will summarize the clinical data for dual- versus single-coil defibrillator leads in the left and right pectoral implant locations, and will then discuss the clinical implications of single- versus dual-coil usage for atrial defibrillation, venous complications, and the risks associated with lead extraction. It will be noted that there are no comparative clinical studies on the use and outcomes of single- versus dual-coil lead systems in implantable defibrillator therapy over a long-term follow-up. The limited long-term reliability of defibrillator leads is a major concern in implantable defibrillator and cardiac resynchronization therapy. A simpler single-coil defibrillator lead system may improve the long-term performance of implanted leads. Furthermore, the superior vena cava coil is suspected to increase interventional risk in transvenous lead extraction. Therefore, the need for objective data on extractions and complications will be emphasized.

Entities:  

Mesh:

Year:  2012        PMID: 22231644     DOI: 10.1007/s00392-011-0407-z

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  64 in total

1.  Transvenous implantable cardioverter-defibrillator leads: the weakest link.

Authors:  William H Maisel
Journal:  Circulation       Date:  2007-05-15       Impact factor: 29.690

2.  Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms.

Authors:  C D Swerdlow; W Fan; J E Brewer
Journal:  Circulation       Date:  1996-11-01       Impact factor: 29.690

3.  Comparison of defibrillation efficacy using implantable cardioverter-defibrillator with single- or dual-coil defibrillation leads and active can.

Authors:  Andrzej Lubiński; Ewa Lewicka-Nowak; Agnieszka Zienciuk; Tomasz Królak; Maciej Kempa; Anna Pazdyga; Grzegorz Raczak; Grazyna Swiatecka
Journal:  Kardiol Pol       Date:  2005-09       Impact factor: 3.108

4.  Optimal electrode position for transvenous defibrillation: a prospective randomized study.

Authors:  K C Stajduhar; G Y Ott; J Kron; J H McAnulty; R P Oliver; B T Reynolds; S W Adler; B D Halperin
Journal:  J Am Coll Cardiol       Date:  1996-01       Impact factor: 24.094

Review 5.  Venous thrombosis and stenosis after implantation of pacemakers and defibrillators.

Authors:  Grzegorz Rozmus; James P Daubert; David T Huang; Spencer Rosero; Burr Hall; Charles Francis
Journal:  J Interv Card Electrophysiol       Date:  2005-06       Impact factor: 1.900

Review 6.  ICD leads: design and chronic dysfunctions.

Authors:  Rainer Gradaus; Günter Breithardt; Dirk Böcker
Journal:  Pacing Clin Electrophysiol       Date:  2003-02       Impact factor: 1.976

7.  Addition of a defibrillation electrode in the low right atrium to a right ventricular lead does not reduce ventricular defibrillation thresholds.

Authors:  Norman Rüb; Oliver Schweitzer; Christian Mewis; Klaus Kettering; Volker Kuehlkamp
Journal:  Pacing Clin Electrophysiol       Date:  2004-03       Impact factor: 1.976

8.  Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: implications for implantation and management.

Authors:  Joshua M Cooper; Elizabeth A Stephenson; Charles I Berul; Edward P Walsh; Laurence M Epstein
Journal:  J Cardiovasc Electrophysiol       Date:  2003-04

9.  "Home monitoring" for early detection of implantable cardioverter-defibrillator failure: a single-center prospective observational study.

Authors:  Melanie Hauck; Alexander Bauer; Frederik Voss; Slawomir Weretka; Hugo A Katus; Ruediger Becker
Journal:  Clin Res Cardiol       Date:  2008-09-05       Impact factor: 5.460

10.  Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing.

Authors:  Jeff S Healey; Paul Dorian; L Brent Mitchell; Mario Talajic; Francois Philippon; Chris Simpson; Raymond Yee; Carlos A Morillo; Andre Lamy; Magdy Basta; David H Birnie; Xiaoyin Wang; Girish M Nair; Eugene Crystal; Charles R Kerr; Stuart J Connolly
Journal:  J Cardiovasc Electrophysiol       Date:  2009-10-05
View more
  7 in total

1. 

Authors:  A Markewitz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-03

2.  Possible spontaneous PFO closure after thrombus trapped in PFO.

Authors:  Antonia Schulz; Telse Hauschild; Franz X Kleber
Journal:  Clin Res Cardiol       Date:  2014-01-19       Impact factor: 5.460

Review 3.  Post cardiac injury syndrome after initially uncomplicated CRT-D implantation: a case report and a systematic review.

Authors:  Farbod Sedaghat-Hamedani; Edgar Zitron; Elham Kayvanpour; Hanns-Martin Lorenz; Hugo A Katus; Benjamin Meder
Journal:  Clin Res Cardiol       Date:  2014-04-29       Impact factor: 5.460

Review 4.  [Annual report 2015 of the German cardiac pacemaker and defibrillator register-Part 2: implantable cardioverter-defibrillators : Cardiac pacemaker working group at the IQTIG - Institute for quality assurance and transparency in health care].

Authors:  A Markewitz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2018-03

5.  Comparison of single-coil lead versus dual-coil lead of implantable cardioverter defibrillator on lead-related venous complications in a canine model.

Authors:  Ziqing Yu; Yuan Wu; Shengmei Qin; Jingfeng Wang; Xueying Chen; Ruizhen Chen; Yangang Su; Junbo Ge
Journal:  J Interv Card Electrophysiol       Date:  2018-03-23       Impact factor: 1.900

6.  Not left ventricular lead position, but the extent of immediate asynchrony reduction predicts long-term response to cardiac resynchronization therapy.

Authors:  Wolfram C Poller; Henryk Dreger; Marius Schwerg; Hansjürgen Bondke; Christoph Melzer
Journal:  Clin Res Cardiol       Date:  2014-01-28       Impact factor: 5.460

7.  Low efficacy of cardioversion of persistent atrial fibrillation with the implantable cardioverter-defibrillator.

Authors:  I Limantoro; K Vernooy; B Weijs; R Pisters; L Debie; H J Crijns; Y Blaauw
Journal:  Neth Heart J       Date:  2013-12       Impact factor: 2.380

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.