Literature DB >> 15976973

Venous thrombosis and stenosis after implantation of pacemakers and defibrillators.

Grzegorz Rozmus1, James P Daubert, David T Huang, Spencer Rosero, Burr Hall, Charles Francis.   

Abstract

Venous complications of pacemaker/ implantable cardioverter defibrillator (ICD) system implantation rarely cause immediate clinical problems. The challenge starts when patients come for system revision or upgrade. Numerous reports of venous complications such as stenosis, occlusions, and superior vena cava syndrome have been published. We reviewed current knowledge of these complications, management, and their impact on upgrade/revision procedures. One study has suggested that intravenous lead infection promotes local vein stenosis. Another found that the presence of a temporary wire before implantation is associated with an increased risk of stenosis. Although data for ICD leads is based only on three studies-it suggests that the rate of venous complications is very similar to that of pacing systems, and probably data from pacing leads can be extrapolated to ICD leads. Despite 40 years of experience with transcutaneous implanted intravenous pacing systems and dozens of studies, we were unable to identify clear risk factors (confirmed by independent studies) that lead to venous stenosis. Neither the hardware (lead size, number and material) nor the access site choice (cephalic cut down, subclavian or axillary puncture) appears to affect rate of venous complications. A few factors were proposed as predictors of severe venous stenosis/occlusion: presence of multiple pacemaker leads (compared to a single lead), use of hormone therapy, personal history of venous thrombosis, the presence of temporary wire before implantation, previous presence of a pacemaker (ICD as an upgrade) and the use of dual-coil leads. Anticoagulant therapy (for other reasons than pacemaker lead) seemed to have protective antithrombotic effect.

Entities:  

Mesh:

Year:  2005        PMID: 15976973     DOI: 10.1007/s10840-005-1140-1

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  53 in total

Review 1.  Upper-extremity deep vein thrombosis.

Authors:  Hylton V Joffe; Samuel Z Goldhaber
Journal:  Circulation       Date:  2002-10-01       Impact factor: 29.690

2.  Prevalence of central venous occlusion in patients with chronic defibrillator leads.

Authors:  C Sticherling; S P Chough; R L Baker; K Wasmer; H Oral; H Tada; L Horwood; M H Kim; F Pelosi; G F Michaud; S A Strickberger; F Morady; B P Knight
Journal:  Am Heart J       Date:  2001-05       Impact factor: 4.749

3.  Pacemaker-induced superior vena cava syndrome: consideration of management.

Authors:  T Blackburn; M Dunn
Journal:  Am Heart J       Date:  1988-09       Impact factor: 4.749

4.  Treatment of subclavian-axillary vein thrombosis: long-term outcome of anticoagulation versus systemic thrombolysis.

Authors:  Schila Sabeti; Martin Schillinger; Wolfgang Mlekusch; Markus Haumer; Ramazanali Ahmadi; Erich Minar
Journal:  Thromb Res       Date:  2002-12-15       Impact factor: 3.944

Review 5.  Upper extremity deep venous thrombosis.

Authors:  Aruna Kommareddy; Michael H Zaroukian; Houria I Hassouna
Journal:  Semin Thromb Hemost       Date:  2002-02       Impact factor: 4.180

6.  Natural history of major venous thrombosis of the upper extremity.

Authors:  M L Tilney; H J Griffiths; E A Edwards
Journal:  Arch Surg       Date:  1970-12

Review 7.  Noninvasive and venographic diagnosis of deep vein thrombosis.

Authors:  M A Bettmann
Journal:  Cardiovasc Intervent Radiol       Date:  1988       Impact factor: 2.740

8.  Echographic detection of latent severe thrombotic stenosis of the superior vena cava and innominate vein in patients with a pacemaker: integrated diagnosis using sonography, pulse Doppler, and color flow.

Authors:  M Nishino; J Tanouchi; T Ito; K Tanaka; T Aoyama; M Kitamura; T Nakagawa; J Kato; Y Yamada
Journal:  Pacing Clin Electrophysiol       Date:  1997-04       Impact factor: 1.976

Review 9.  Venous complications after insertion of a transvenous pacemaker.

Authors:  P C Spittell; D L Hayes
Journal:  Mayo Clin Proc       Date:  1992-03       Impact factor: 7.616

10.  The incidence and risk factors for venous obstruction after implantation of transvenous pacing leads.

Authors:  Yasushi Oginosawa; Haruhiko Abe; Yasuhide Nakashima
Journal:  Pacing Clin Electrophysiol       Date:  2002-11       Impact factor: 1.976

View more
  44 in total

Review 1.  Dual- versus single-coil implantable defibrillator leads: review of the literature.

Authors:  Jörg Neuzner; Jörg Carlsson
Journal:  Clin Res Cardiol       Date:  2012-01-10       Impact factor: 5.460

2.  Upper limb DVT after an optical urethrotomy in a patient with a permanent pacemaker: a case for continuing anticoagulation during low-risk urological surgery.

Authors:  Samiha Hayek; Deepak Batura
Journal:  Int Urol Nephrol       Date:  2015-10-03       Impact factor: 2.370

3.  Right giant atrial thrombosis and pulmonary embolism complicating pacemaker leads.

Authors:  Antonio D'Aloia; Ivano Bonadei; Enrico Vizzardi; Antonio Curnis
Journal:  BMJ Case Rep       Date:  2013-08-30

4.  Incidence and predictors of subclavian vein obstruction following biventricular device implantation.

Authors:  Serkan Bulur; Ahmet Vural; Mehmet Yazıcı; Gökhan Ertaş; Hakan Özhan; Dilek Ural
Journal:  J Interv Card Electrophysiol       Date:  2010-10-02       Impact factor: 1.900

5.  Fatal cardiac thromboembolism in a patient with a pacemaker during ureteroscopic lithotripsy for ureter stone: a case report.

Authors:  Mee Young Chung; Su Min Chae; Chang Jae Kim
Journal:  Korean J Anesthesiol       Date:  2015-01-28

6.  Acute subclavian vein occlusion complicating biventricular ICD implantation.

Authors:  David D Spragg; Joseph E Marine
Journal:  J Interv Card Electrophysiol       Date:  2008-02-01       Impact factor: 1.900

Review 7.  [Upgrading to biventricular pacing: indications and procedural challenges].

Authors:  H-H Minden; C Butter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12

8.  Acute superior vena cava syndrome after insertion of implantable cardioverter defibrillator.

Authors:  Andrea Rossi; Massimo Baravelli; Paolo Cattaneo; Melania Romano; Giovanni Mariscalco; Daniela Imperiale; Maria Cristina Rossi; Anna Picozzi; Paola Dario; Claudio Anza; Annibale Sandro Montenero
Journal:  J Interv Card Electrophysiol       Date:  2008-09-23       Impact factor: 1.900

9.  An unusual clinical presentation resembling superior vena cava syndrome post heart surgery.

Authors:  Angel López-Candales; David Kaczorowski; Ronald Pellegrini
Journal:  Cardiovasc Ultrasound       Date:  2005-10-03       Impact factor: 2.062

10.  Implanted endocardial lead characteristics and risk of stroke or transient ischemic attack.

Authors:  Vaibhav R Vaidya; Christopher V DeSimone; Samuel J Asirvatham; Vishnu M Chandra; Amit Noheria; David O Hodge; Joshua P Slusser; Alejandro A Rabinstein; Paul A Friedman
Journal:  J Interv Card Electrophysiol       Date:  2014-04-27       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.