Literature DB >> 22230812

State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods.

Christopher-John L Farrell1, Steven Martin, Brett McWhinney, Isabella Straub, Paul Williams, Markus Herrmann.   

Abstract

BACKGROUND: Vitamin D testing is increasing worldwide. Recently several diagnostic manufacturers including Abbott and Siemens have launched automated 25-hydroxy vitamin D (25OH-D) immunoassays. Furthermore, preexisting assays from DiaSorin and Roche have recently been modified. We compared the performance of 5 automated immunoassays, an RIA and 2 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods.
METHODS: Aliquots of 170 randomly selected patient samples were prepared and 25OH-D was measured by 2 LC-MS/MS methods, an RIA (DiaSorin), and automated immunoassays from Abbott (Architect), DiaSorin (LIAISON), IDS (ISYS), Roche (E170, monoclonal 25OH-D(3) assay), and Siemens (Centaur). Within-run and between-run imprecision were evaluated by measurement of 5 replicates of 2 serum pools on 5 consecutive days.
RESULTS: The LC-MS/MS methods agreed, with a concordance correlation coefficient (CCC) of 0.99 and bias of 0.56 μg/L (1.4 nmol/L). The RIA assay showed a performance comparable to LC-MS/MS, with a CCC of 0.97 and a mean bias of 1.1 μg/L (2.7 nmo/L). All immunoassays measured total 25OH-D (including D(3) and D(2)), with the exception of the Roche assay (D(3) only). Among the immunoassays detecting total 25OH-D, the CCCs varied between 0.85 (Abbott) to 0.95 (LIAISON). The mean bias ranged between 0.2 μg/L (0.5 nmol/L) (LIAISON) and 4.56 μg/L (11.4 nmol/L) (Abbott). The Roche 25OH-D(3) assay demonstrated small mean bias [-2.7 μg/L (-6.7 nmol/L)] [-2.7 μg/L (-6.7 nmol/L)] but a low CCC of just 0.66. Most assays demonstrated good intra- and interassay precision, with CV <10%.
CONCLUSIONS: Automated immunoassays demonstrated variable performance and not all tests met our minimum performance goals. It is important that laboratories be aware of the limitations of their assay.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22230812     DOI: 10.1373/clinchem.2011.172155

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  101 in total

1.  Effect of vitamin D3 treatment on endothelial function in obese adolescents.

Authors:  A Javed; I J Kullo; P Babu Balagopal; S Kumar
Journal:  Pediatr Obes       Date:  2015-08-14       Impact factor: 4.000

2.  Standardization of measurements of 25-hydroxyvitamin D3 and D2.

Authors:  Linda M Thienpont; Hedwig C M Stepman; Hubert W Vesper
Journal:  Scand J Clin Lab Invest Suppl       Date:  2012

3.  Dietary, lifestyle, and genetic determinants of vitamin D status: a cross-sectional analysis from the European Prospective Investigation into Cancer and Nutrition (EPIC)-Germany study.

Authors:  Tilman Kühn; Rudolf Kaaks; Birgit Teucher; Frank Hirche; Jutta Dierkes; Cornelia Weikert; Verena Katzke; Heiner Boeing; Gabriele I Stangl; Brian Buijsse
Journal:  Eur J Nutr       Date:  2013-09-05       Impact factor: 5.614

Review 4.  Current Controversies: Are Free Vitamin Metabolite Levels a More Accurate Assessment of Vitamin D Status than Total Levels?

Authors:  Daniel D Bikle; Sofie Malmstroem; Janice Schwartz
Journal:  Endocrinol Metab Clin North Am       Date:  2017-12       Impact factor: 4.741

5.  Prevalence and Predictors of Low Serum 25-Hydroxyvitamin D among Female African-American Breast Cancer Survivors.

Authors:  Patricia Sheean; Claudia Arroyo; Jennifer Woo; Linda Schiffer; Melinda Stolley
Journal:  J Acad Nutr Diet       Date:  2018-01-02       Impact factor: 4.910

Review 6.  Fat-Soluble Vitamins: Clinical Indications and Current Challenges for Chromatographic Measurement.

Authors:  Ali A Albahrani; Ronda F Greaves
Journal:  Clin Biochem Rev       Date:  2016-02

7.  Serum 25-hydroxyvitamin D cutoffs for functional bone measures in postmenopausal osteoporosis.

Authors:  D Y Lee; J H Jee; Y Y Cho; J Y Jang; T Y Yu; T H Kim; Y J Hong; W-J Hong; S-M Jin; K Y Hur; J H Kim; S W Kim; J H Chung; M K Lee; Y-K Min
Journal:  Osteoporos Int       Date:  2017-02-10       Impact factor: 4.507

8.  Various calibration procedures result in optimal standardization of routinely used 25(OH)D ID-LC-MS/MS methods.

Authors:  Niek F Dirks; Hubert W Vesper; Antonius E van Herwaarden; Jody M W van den Ouweland; Ido P Kema; Johannes G Krabbe; Annemieke C Heijboer
Journal:  Clin Chim Acta       Date:  2016-08-25       Impact factor: 3.786

9.  Low vitamin D status among pregnant Latin American and Caribbean women with HIV Infection.

Authors:  Jennifer Jao; Laura Freimanis; Marisa M Mussi-Pinhata; Rachel A Cohen; Jacqueline P Monteiro; Maria L Cruz; Rhoda S Sperling; Andrea Branch; George K Siberry
Journal:  Int J Gynaecol Obstet       Date:  2015-04-11       Impact factor: 3.561

Review 10.  Vitamin D and metabolites measurement by tandem mass spectrometry.

Authors:  Johannes M W van den Ouweland; Michael Vogeser; Silvia Bächer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.