Literature DB >> 22229823

Comparative assessment of clinical performance of esthetic bracket materials.

Nikolaos Gkantidis1, Spiros Zinelis, Marina Karamolegkou, Theodore Eliades, Nikolaos Topouzelis.   

Abstract

OBJECTIVES: To compare the alterations in esthetic appearance and slot morphology/integrity of two main types of esthetic brackets caused after clinical use.
MATERIALS AND METHODS: Sixteen ceramic (CR) and 16 plastic (PR) central incisor brackets were obtained from 16 young adult patients at the end of treatment in a prospective randomized manner. As controls, 12 ceramic (CC) and 12 plastic (PC) nonused brackets were also examined. Three representative slot width measurements were obtained through micrometric microscopy. Visual inspection of optical microscopy images, surface electron microscopy (SEM), and energy-dispersive x-ray spectroscopy (EDS) were also performed.
RESULTS: Intraoral exposure time varied from 5 to 20 months (mean, 12.4; P  =  .73). Two-way analysis of variance revealed significant differences in slot width among the different materials and a significant interaction between the material effect and its status (P < .001). Bonferroni post hoc tests on material × status effect showed significant differences between CC (95% confidence interval [CI]: 434.5, 447.0) vs PC (95% CI: 460.2, 472.8), CC vs CR (95% CI: 453.2, 464.4), and PC vs PR (95% CI: 448.8, 458.9). Interestingly, a significant difference was not detected for CR vs PR. Slot width was correlated with the time under clinical use only for plastic brackets (PR: r  =  -.64, P < .01). Visual inspection of the optical microscopy images did not reveal any major macroscopic morphological disfigurements or significant discolorations. However, a rough and irregular slot wall surface was evident after clinical use (also with SEM), especially in the bottom of the slot.
CONCLUSIONS: Both bracket types presented adequate clinical performance at least for the time period studied and in terms of esthetic appearance and morphologic integrity.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22229823      PMCID: PMC8845544          DOI: 10.2319/092511-605.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  17 in total

1.  Comparative assessment of the roughness, hardness, and wear resistance of aesthetic bracket materials.

Authors:  Spiros Zinelis; Theodore Eliades; George Eliades; Margarita Makou; Nikolaos Silikas
Journal:  Dent Mater       Date:  2005-09       Impact factor: 5.304

2.  Plastic brackets: hardness and associated clinical implications.

Authors:  Theodore Eliades; Christiana Gioka; Spiros Zinelis; George Eliades; Margarita Makou
Journal:  World J Orthod       Date:  2004

3.  Bond strength of direct and indirect bonded brackets after thermocycling.

Authors:  Jacob Daub; David W Berzins; Brandon James Linn; Thomas Gerard Bradley
Journal:  Angle Orthod       Date:  2006-03       Impact factor: 2.079

4.  Torque stability of plastic brackets following multiple loading and artificial material aging--an in-vitro comparison.

Authors:  Matthias Möller; Arndt Klocke; Reza Sadat-Khonsari; Volker Schlegel; Bärbel Kahl-Nieke
Journal:  J Orofac Orthop       Date:  2009-12-09       Impact factor: 1.938

5.  Torsional creep of polycarbonate orthodontic brackets.

Authors:  R G Alkire; M D Bagby; M A Gladwin; H Kim
Journal:  Dent Mater       Date:  1997-01       Impact factor: 5.304

6.  Presence of cariogenic streptococci on various bracket materials detected by polymerase chain reaction.

Authors:  Smitha Pramod; Vignesh Kailasam; Sridevi Padmanabhan; Arun B Chitharanjan
Journal:  Aust Orthod J       Date:  2011-05

7.  Failure mode analysis of ceramic brackets bonded to enamel.

Authors:  T Eliades; A D Viazis; M Lekka
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-07       Impact factor: 2.650

8.  Bacterial adhesion of Streptococcus mutans to esthetic bracket materials.

Authors:  Andreas Faltermeier; Ralf Bürgers; Martin Rosentritt
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-04       Impact factor: 2.650

9.  Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets.

Authors:  Enver Morina; Theodore Eliades; Nikolaos Pandis; Andreas Jäger; Christoph Bourauel
Journal:  Eur J Orthod       Date:  2008-06       Impact factor: 3.075

10.  Evaluation of esthetic brackets' resistance to torsional forces from the archwire.

Authors:  Clarice Nishio; Alvaro de Moraes Mendes; Marco Antonio de Oliveira Almeida; Eiji Tanaka; Kazuo Tanne; Carlos Nelson Elias
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-01       Impact factor: 2.650

View more
  8 in total

1.  Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis.

Authors:  Spyridon N Papageorgiou; Ludger Keilig; Istabrak Hasan; Andreas Jäger; Christoph Bourauel
Journal:  Eur J Orthod       Date:  2015-07-14       Impact factor: 3.075

2.  Sliding behaviour and surface quality after static air polishing of conventional and modern bracket materials : In vitro analysis.

Authors:  Lutz Hodecker; Christoph Bourauel; Bert Braumann; Teresa Kruse; Hildegard Christ; Sven Scharf
Journal:  J Orofac Orthop       Date:  2021-09-23       Impact factor: 1.938

3.  Comparison of two different debonding techniques in orthodontic treatment.

Authors:  Luca Piccoli; Guido Migliau; Laith Konstantinos Besharat; Stefano Di Carlo; Giorgio Pompa; Roberto Di Giorgio
Journal:  Ann Stomatol (Roma)       Date:  2017-11-08

4.  Color stability of ceramic brackets immersed in potentially staining solutions.

Authors:  Bruna Coser Guignone; Ludimila Karsbergen Silva; Rodrigo Villamarim Soares; Emilio Akaki; Marcelo Coelho Goiato; Matheus Melo Pithon; Dauro Douglas Oliveira
Journal:  Dental Press J Orthod       Date:  2015 Jul-Aug

5.  Clinical effectiveness of Invisalign® orthodontic treatment: a systematic review.

Authors:  Aikaterini Papadimitriou; Sophia Mousoulea; Nikolaos Gkantidis; Dimitrios Kloukos
Journal:  Prog Orthod       Date:  2018-09-28       Impact factor: 2.750

6.  Color Stability, Chemico-Physical and Optical Features of the Most Common PETG and PU Based Orthodontic Aligners for Clear Aligner Therapy.

Authors:  Valeria Daniele; Ludovico Macera; Giuliana Taglieri; Loredana Spera; Giuseppe Marzo; Vincenzo Quinzi
Journal:  Polymers (Basel)       Date:  2021-12-21       Impact factor: 4.329

7.  Assessment of Bracket Surface Morphology and Dimensional Change.

Authors:  Pillai Devu Radhakrishnan; N K Sapna Varma; V V Ajith
Journal:  Contemp Clin Dent       Date:  2017 Jan-Mar

8.  Surface analysis of metal clips of ceramic self-ligating brackets.

Authors:  Kyung Sook Kim; Se Jik Han; Tae-Hee Lee; Tae-Joon Park; Samjin Choi; Yoon-Goo Kang; Ki-Ho Park
Journal:  Korean J Orthod       Date:  2018-12-19       Impact factor: 1.372

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.