Literature DB >> 22225323

CT-PET weighted image fusion for separately scanned whole body rat.

Jung W Suh1, Oh-Kyu Kwon, Dustin Scheinost, Albert J Sinusas, Gary W Cline, Xenophon Papademetris.   

Abstract

PURPOSE: The limited resolution and lack of spatial information in positron emission tomography (PET) images require the complementary anatomic information from the computed tomography (CT) and/or magnetic resonance imaging (MRI). Therefore, multimodality image fusion techniques such as PET/CT are critical in mapping the functional images to structural images and thus facilitate the interpretation of PET studies. In our experimental situation, the CT and PET images are acquired in separate scanners at different times and the inherent differences in the imaging protocols produce significant nonrigid changes between the two acquisitions in addition to dissimilar image characteristics. The registration conditions are also poor because CT images have artifacts due to the limitation of current scanning settings, while PET images are very blurry (in transmission-PET) and have vague anatomical structure boundaries (in emission-PET).
METHODS: The authors present a new method for whole body small animal multimodal registration. In particular, the authors register whole body rat CT image and PET images using a weighted demons algorithm. The authors use both the transmission-PET and the emission-PET images in the registration process emphasizing particular regions of the moving transmission-PET image using the emission-PET image. After a rigid transformation and a histogram matching between the CT and the transmission-PET images, the authors deformably register the transmission-PET image to the CT image with weights based on the intensity-normalized emission-PET image. For the deformable registration process, the authors develop a weighted demons registration method that can give preferences to particular regions of the input image using a weight image.
RESULTS: The authors validate the results with nine rat image sets using the M-Hausdorff distance (M-HD) similarity measure with different outlier-suppression parameters (OSP). In comparison with standard methods such as the regular demons and the normalized mutual information (NMI)-based nonrigid free-form deformation (FFD) registration, the proposed weighted demons registration method shows average M-HD errors: 3.99 ± 1.37 (OSP = 10), 5.04 ± 1.59 (OSP = 20) and 5.92 ± 1.61 (OSP = ∞) with statistical significance (p < 0.0003) respectively, while NMI-based nonrigid FFD has average M-HD errors: 5.74 ± 1.73 (OSP = 10), 7.40 ± 7.84 (OSP = 20) and 9.83 ± 4.13 (OSP = ∞), and the regular demons has average M-HD errors: 6.79 ± 0.83 (OSP = 10), 9.19 ± 2.39 (OSP = 20) and 11.63 ± 3.99 (OSP = ∞), respectively. In addition to M-HD comparisons, the visual comparisons on the faint-edged region between the CT and the aligned PET images also show the encouraging improvements over the other methods.
CONCLUSIONS: In the whole body multimodal registration between CT and PET images, the utilization of both the transmission-PET and the emission-PET images in the registration process by emphasizing particular regions of the transmission-PET image using an emission-PET image is effective. This method holds promise for other image fusion applications where multiple (more than two) input images should be registered into a single informative image.

Entities:  

Mesh:

Year:  2012        PMID: 22225323      PMCID: PMC3266828          DOI: 10.1118/1.3672167

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  A PET-MRI registration technique for PET studies of the rat brain.

Authors:  N Hayakawa; K Uemura; K Ishiwata; Y Shimada; N Ogi; T Nagaoka; H Toyama; K Oda; A Tanaka; K Endo; M Senda
Journal:  Nucl Med Biol       Date:  2000-02       Impact factor: 2.408

2.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

3.  PET-CT image registration in the chest using free-form deformations.

Authors:  David Mattes; David R Haynor; Hubert Vesselle; Thomas K Lewellen; William Eubank
Journal:  IEEE Trans Med Imaging       Date:  2003-01       Impact factor: 10.048

4.  Automated registration of whole-body follow-up MicroCT data of mice.

Authors:  Martin Baiker; Marius Staring; Clemens W G M Löwik; Johan H C Reiber; Boudewijn P F Lelieveldt
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

5.  POSTURE MATCHING AND ELASTIC REGISTRATION OF A MOUSE ATLAS TO SURFACE TOPOGRAPHY RANGE DATA.

Authors:  A A Joshi; A J Chaudhari; Changqing Li; D W Shattuck; J Dutta; R M Leahy; A W Toga
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-08-07

6.  A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images.

Authors:  Meei-Ling Jan; Keh-Shih Chuang; Guo-Wei Chen; Yu-Ching Ni; Sharon Chen; Chih-Hsien Chang; Jay Wu; Te-Wei Lee; Ying-Kai Fu
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

7.  Object matching algorithms using robust Hausdorff distance measures.

Authors:  D G Sim; O K Kwon; R H Park
Journal:  IEEE Trans Image Process       Date:  1999       Impact factor: 10.856

8.  Image matching as a diffusion process: an analogy with Maxwell's demons.

Authors:  J P Thirion
Journal:  Med Image Anal       Date:  1998-09       Impact factor: 8.545

9.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

10.  BioImage Suite: An integrated medical image analysis suite: An update.

Authors:  Xenophon Papademetris; Marcel P Jackowski; Nallakkandi Rajeevan; Marcello DiStasio; Hirohito Okuda; R Todd Constable; Lawrence H Staib
Journal:  Insight J       Date:  2006
View more
  4 in total

1.  Patient-specific biomechanical model as whole-body CT image registration tool.

Authors:  Mao Li; Karol Miller; Grand Roman Joldes; Barry Doyle; Revanth Reddy Garlapati; Ron Kikinis; Adam Wittek
Journal:  Med Image Anal       Date:  2015-01-30       Impact factor: 8.545

2.  Biomechanical model for computing deformations for whole-body image registration: A meshless approach.

Authors:  Mao Li; Karol Miller; Grand Roman Joldes; Ron Kikinis; Adam Wittek
Journal:  Int J Numer Method Biomed Eng       Date:  2016-03-14       Impact factor: 2.747

3.  Registration of PET and CT images based on multiresolution gradient of mutual information demons algorithm for positioning esophageal cancer patients.

Authors:  Shuo Jin; Dengwang Li; Hongjun Wang; Yong Yin
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

4.  Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.

Authors:  Juan Yang; Hongjun Wang; You Zhang; Yong Yin
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.