Literature DB >> 22218147

Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

Jorge L Alio1, Ana B Plaza-Puche, Jaime Javaloy, María José Ayala, Luis J Moreno, David P Piñero.   

Abstract

PURPOSE: To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL.
DESIGN: Prospective, comparative, nonrandomized, consecutive case series. PARTICIPANTS: Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany).
METHODS: All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. MAIN OUTCOME MEASURES: Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve.
RESULTS: A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04).
CONCLUSIONS: The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Copyright Â
© 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22218147     DOI: 10.1016/j.ophtha.2011.08.036

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  24 in total

1.  Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

Authors:  Emilio Pedrotti; Rodolfo Mastropasqua; Jacopo Bonetto; Christian Demasi; Francesco Aiello; Carlo Nucci; Cesare Mariotti; Giorgio Marchini
Journal:  Int Ophthalmol       Date:  2017-07-17       Impact factor: 2.031

2.  Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

Authors:  David P Piñero; Vicente J Camps; María L Ramón; Verónica Mateo; Rafael J Pérez-Cambrodí
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

Review 3.  Clinical application of accommodating intraocular lens.

Authors:  You-Ling Liang; Song-Bai Jia
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

4.  Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

Authors:  M Ouchi; S Kinoshita
Journal:  Eye (Lond)       Date:  2015-03-06       Impact factor: 3.775

5.  Model of the light sword intraocular lens: in-vitro comparative studies.

Authors:  Krzysztof Petelczyc; Andrzej Kolodziejczyk; Narcyz Błocki; Anna Byszewska; Zbigniew Jaroszewicz; Karol Kakarenko; Katarzyna Kołacz; Michał Miler; Alejandro Mira-Agudelo; Walter Torres-Sepúlveda; Marek Rękas
Journal:  Biomed Opt Express       Date:  2019-12-04       Impact factor: 3.732

6.  Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation.

Authors:  Hungwon Tchah; Kiyeun Nam; Aeri Yoo
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

7.  Binocular visual function after unilateral versus bilateral implantation of segmented refractive multifocal intraocular lenses: a pilot study.

Authors:  Yiyun Liu; Qianqian Lan; Tong Sun; Chuhao Tang; Tingting Yang; Hongyu Duan; Rongjun Liu; Hong Qi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-11-26       Impact factor: 3.117

8.  Method for the generation and visualization of cross-sectional images of three-dimensional point spread functions for rotationally symmetric intraocular lenses.

Authors:  Jan Sievers; Ricardo Elsner; Sebastian Bohn; Melanie Schünemann; Heinrich Stolz; Rudolf F Guthoff; Oliver Stachs; Karsten Sperlich
Journal:  Biomed Opt Express       Date:  2022-02-01       Impact factor: 3.732

9.  [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

Authors:  B C Thomas; G U Auffarth; R Philips; J Novák; J Blazek; H Adamkova; T M Rabsilber
Journal:  Ophthalmologe       Date:  2013-11       Impact factor: 1.059

10.  Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study.

Authors:  Chandra Bala; Jeffrey Shi; Kerrie Meades
Journal:  Transl Vis Sci Technol       Date:  2015-06-11       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.