A comparison of conductivity-based hematocrit determinations with conventional laboratory methods in autologous blood transfusions.

D J McMahon1, R L Carpenter.   

Abstract

An investigation was made of the accuracy of a portable hematocrit measurement device (Stat-Crit) on the infusate of an autologous blood transfusion system. Baseline hematocrit values were determined by three methods on in vivo blood samples of surgical patients immediately after the start of surgery, and again on the first product of the autologous blood retrieval system. At baseline, there were no significant differences in the values determined by the Stat-Crit (33.4% +/- 6.2%, mean +/- SD) and those determined by the microcentrifuge technique (33.8% +/- 4.7%) or by the Coulter method (33.5% +/- 4.5%) (P = 0.9). In contrast, hematocrit values determined on infusate samples by the Stat-Crit (36.6% +/- 4.8%) were significantly lower than those determined by the microcentrifuge technique (51.2% +/- 5.9%) or by the Coulter method (51.6% +/- 5.8%) (P = 0.0001). This study confirms close agreement of hematocrit values derived by the conductivity of whole blood in normal samples with those determined by conventional laboratory techniques, but indicates that this method will report falsely low readings in situations where plasma has been replaced by crystalloid, as in patients who have received large transfusions of processed autologous blood.

Entities:  

Mesh:

Year:  1990        PMID: 2221416     DOI: 10.1213/00000539-199011000-00015

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  7 in total

1.  Hemoglobin test result variability and cost analysis of eight different analyzers during open heart surgery.

Authors:  Kirti P Patel; Gary W Hay; Mahesh Keitheri Cheteri; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-03

2.  The use of the iSTAT portable analyzer in patients undergoing cardiopulmonary bypass.

Authors:  N R Connelly; M Magee; B Kiessling
Journal:  J Clin Monit       Date:  1996-07

3.  Bedside hemoglobin measurements: sensitivity to changes in serum protein and electrolytes.

Authors:  S E McNulty; S J Sharkey; H Schieren
Journal:  J Clin Monit       Date:  1994-11

4.  Clinical evaluation of the ABL-77 for point-of-care analysis in the cardiovascular operating room.

Authors:  Jack S Prichard; John S French; Nestor Alvar
Journal:  J Extra Corpor Technol       Date:  2006-06

5.  Back to the "Gold Standard": How Precise is Hematocrit Detection Today?

Authors:  Leonid Livshits; Tal Bilu; Sari Peretz; Anna Bogdanova; Max Gassmann; Harel Eitam; Ariel Koren; Carina Levin
Journal:  Mediterr J Hematol Infect Dis       Date:  2022-07-01       Impact factor: 3.122

6.  Comparison of four different hematocrit assays and the effect of albumin on their measurements.

Authors:  Amelie Pare; Laura Kippen; Catherine Wagg; Matt Longmore; Soren Boysen
Journal:  Front Vet Sci       Date:  2022-08-24

7.  Point-of-care versus central testing of hemoglobin during large volume blood transfusion.

Authors:  Justin Herman; Brian Park; Bharat Awsare; Frances West; Denine Crittendon; Lilah Evans; Mary Harach; Julie Karp; Alexis Peedin; Marianna LaNoue; Barbara Goldsmith; Eugene Warnick; Michael Baram
Journal:  BMC Anesthesiol       Date:  2019-12-27       Impact factor: 2.217

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.