Hemoglobin test result variability and cost analysis of eight different analyzers during open heart surgery.

Kirti P Patel1, Gary W Hay, Mahesh Keitheri Cheteri, David W Holt.   

Abstract

The purpose of this study was to compare the variation in hemoglobin (Hgb) values among various point-of-care (POC) analyzers available on the market. Eight analyzers (Gem 3000, ABL 720, ABL 77, Rapidpoint 405, IL 682, GemOPL, Hb 201+, and manual/centrifugation) were compared with the Hgb values from the Beckman Coulter LH750. A total of 72 patient samples were analyzed on each test instrument. The samples were obtained after intubation, after heparinization, during cardiopulmonary bypass, and after protamine administration. Four of the samples were excluded from the study because of delayed sample analysis. The calculated mean differences of reference test method Hgb (mean +/- SD) for all samples (n = 68) were Gem 3000 = 1.431 +/- 0.396 g/dL; ABL 720 = -0.224 +/- 0.240 g/dL; ABL 77 = 0.341 +/- 0.578 g/dL; Rapidpoint 405 = 0.001 +/- 0.205 g/dL; IL 682 = -0.137 +/- 0.232 g/dL; GemOPL = 0.774 +/- 0.427 g/dL; Hb 201+ = 0.110 +/- 0.524 g/dL; and manual/ centrifugation = 0.547 +/- 0.499 g/dL. Cumulative results indicated that the bias in Hgb values from the Gem 3000, ABL720, ABL 77, IL 682, GemOPL, and the manual method were statistically significant (p < .05), compared with the Coulter LH750. Additionally, only the Rapidpoint 405 and Hb 201+ most closely matched the values from the Coulter LH750 (p > .05). Some of the methodologies have previously been shown to be affected during hemodilution, hypoproteinemia, and/or after blood transfusion. There is variability among methodologies, which can give rise to statistically different Hgb values, and one should consider the "ideal" instrument based on this and many other factors. Based on our results, the rank order of closest approximation to the Coulter LH750 measurement was Rapidpoint 405, Hb 201+, IL 682, ABL 720, ABL 77, manual/centrifugation, GemOPL, and Gem 3000.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17486868      PMCID: PMC4680676     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  34 in total

1.  Point-of-care testing. Impact on medical outcomes.

Authors:  C P Price
Journal:  Clin Lab Med       Date:  2001-06       Impact factor: 1.935

Review 2.  Quality in point-of-care testing.

Authors:  James H Nichols
Journal:  Expert Rev Mol Diagn       Date:  2003-09       Impact factor: 5.225

3.  The significance of the blood gas analyzer.

Authors:  Hershel Raff
Journal:  J Appl Physiol (1985)       Date:  2004-11

4.  Evaluation of STAT-CRIT hematocrit determination in comparison to Coulter and centrifuge: the effects of isotonic hemodilution and albumin administration.

Authors:  S E McNulty; S J Sharkey; B Asam; J H Lee
Journal:  Anesth Analg       Date:  1993-04       Impact factor: 5.108

5.  Bedside hemoglobin measurements: sensitivity to changes in serum protein and electrolytes.

Authors:  S E McNulty; S J Sharkey; H Schieren
Journal:  J Clin Monit       Date:  1994-11

Review 6.  Blood analysis at the point of care: issues in application for use in critically ill patients.

Authors:  Karen K Giuliano; Maria E Grant
Journal:  AACN Clin Issues       Date:  2002-05

Review 7.  Non-pharmacological strategies for blood conservation in cardiac surgery.

Authors:  M A Ruel; F D Rubens
Journal:  Can J Anaesth       Date:  2001-04       Impact factor: 5.063

8.  Evaluation of the blood gas analyzer Gem PREMIER 3000.

Authors:  Bénédicte Bénéteau-Burnat; Marie-Chantal Bocque; Anne Lorin; Catherine Martin; Michel Vaubourdolle
Journal:  Clin Chem Lab Med       Date:  2004-01       Impact factor: 3.694

9.  Accuracy of point-of-care-testing (POCT) for determining hemoglobin concentrations.

Authors:  H Gehring; C Hornberger; L Dibbelt; A Rothsigkeit; K Gerlach; J Schumacher; P Schmucker
Journal:  Acta Anaesthesiol Scand       Date:  2002-09       Impact factor: 2.105

10.  A comparison of four bedside methods of hemoglobin assessment during cardiac surgery.

Authors:  S E McNulty; M Torjman; W Grodecki; A Marr; H Schieren
Journal:  Anesth Analg       Date:  1995-12       Impact factor: 5.108

View more
  6 in total

1.  Comparison of the accuracy of hemoglobin point of care testing using HemoCue and GEM Premier 3000 with automated hematology analyzer in emergency room.

Authors:  Jan Zatloukal; Jiri Pouska; Jakub Kletecka; Richard Pradl; Jan Benes
Journal:  J Clin Monit Comput       Date:  2015-10-27       Impact factor: 2.502

Review 2.  Factors affecting hemoglobin measurement.

Authors:  Lauren Berkow
Journal:  J Clin Monit Comput       Date:  2013-03-26       Impact factor: 2.502

3.  Progressive anemia of prematurity is associated with a critical increase in cerebral oxygen extraction.

Authors:  Halana V Whitehead; Zachary A Vesoulis; Akhil Maheshwari; Ami Rambhia; Amit M Mathur
Journal:  Early Hum Dev       Date:  2019-10-24       Impact factor: 2.079

4.  Simple paper-based test for measuring blood hemoglobin concentration in resource-limited settings.

Authors:  Xiaoxi Yang; Nathaniel Z Piety; Seth M Vignes; Melody S Benton; Julie Kanter; Sergey S Shevkoplyas
Journal:  Clin Chem       Date:  2013-06-20       Impact factor: 8.327

5.  Point-of-Care Testing for Anaemia in Children Using Portable Haematocrit Meter: A Pilot Study from Southwest Nigeria and Implications for Developing Countries.

Authors:  Oladele Olatunya; Olatunde Ogundare; Abiola Olaleye; Oyinkansola Agaja; Evelyn Omoniyi; Babajide Adeyefa; Kehinde Oluwadiya; Oyeku Oyelami
Journal:  Ethiop J Health Sci       Date:  2016-05

6.  Design and Performance of a Low-Cost, Handheld Reader for Diagnosing Anemia in Blantyre, Malawi.

Authors:  Meaghan Bond; Jessica Mvula; Elizabeth Molyneux; Rebecca Richards-Kortum
Journal:  Health Innov Point Care Conf       Date:  2014-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.