Literature DB >> 22208969

Accumulated dose in liver stereotactic body radiotherapy: positioning, breathing, and deformation effects.

Michael Velec1, Joanne L Moseley, Tim Craig, Laura A Dawson, Kristy K Brock.   

Abstract

PURPOSE: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. METHODS AND MATERIALS: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between the accumulated and predicted breathing dose were quantified.
RESULTS: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7).
CONCLUSION: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22208969      PMCID: PMC3337347          DOI: 10.1016/j.ijrobp.2011.09.045

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  27 in total

1.  A method for incorporating organ motion due to breathing into 3D dose calculations.

Authors:  A E Lujan; E W Larsen; J M Balter; R K Ten Haken
Journal:  Med Phys       Date:  1999-05       Impact factor: 4.071

2.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

3.  Accuracy of finite element model-based multi-organ deformable image registration.

Authors:  K K Brock; M B Sharpe; L A Dawson; S M Kim; D A Jaffray
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

4.  Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy.

Authors:  Maria A Hawkins; Kristy K Brock; Cynthia Eccles; Douglas Moseley; David Jaffray; Laura A Dawson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-10-01       Impact factor: 7.038

5.  Hypofractionated stereotactic body radiation therapy (SBRT) for limited hepatic metastases.

Authors:  Alan W Katz; Madeleine Carey-Sampson; Ann G Muhs; Michael T Milano; Michael C Schell; Paul Okunieff
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-29       Impact factor: 7.038

6.  Effect of breathing motion on radiotherapy dose accumulation in the abdomen using deformable registration.

Authors:  Michael Velec; Joanne L Moseley; Cynthia L Eccles; Tim Craig; Michael B Sharpe; Laura A Dawson; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-08-21       Impact factor: 7.038

7.  Individualized image guided iso-NTCP based liver cancer SBRT.

Authors:  Laura A Dawson; Cynthia Eccles; Tim Craig
Journal:  Acta Oncol       Date:  2006       Impact factor: 4.089

8.  Phase II trial of high-dose conformal radiation therapy with concurrent hepatic artery floxuridine for unresectable intrahepatic malignancies.

Authors:  Edgar Ben-Josef; Daniel Normolle; William D Ensminger; Suzette Walker; Daniel Tatro; Randall K Ten Haken; James Knol; Laura A Dawson; Charlie Pan; Theodore S Lawrence
Journal:  J Clin Oncol       Date:  2005-12-01       Impact factor: 44.544

9.  Variability of four-dimensional computed tomography patient models.

Authors:  Jan-Jakob Sonke; Joos Lebesque; Marcel van Herk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-11-26       Impact factor: 7.038

10.  Alterations in normal liver doses due to organ motion.

Authors:  Mihaela Rosu; Laura A Dawson; James M Balter; Daniel L McShan; Theodore S Lawrence; Randall K Ten Haken
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-12-01       Impact factor: 7.038

View more
  21 in total

1.  Characterization of deformation and physical force in uniform low contrast anatomy and its impact on accuracy of deformable image registration.

Authors:  Raj Varadhan; Taiki Magome; Susanta Hui
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Four-dimensional radiotherapeutic dose calculation using biomechanical respiratory motion description.

Authors:  Petru Manescu; Hamid Ladjal; Joseph Azencot; Michael Beuve; Etienne Testa; Behzad Shariat
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-09-01       Impact factor: 2.924

3.  Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections.

Authors:  You Zhang; Fang-Fang Yin; Tinsu Pan; Irina Vergalasova; Lei Ren
Journal:  Radiother Oncol       Date:  2015-03-26       Impact factor: 6.280

4.  An evaluation of techniques for dose calculation on cone beam computed tomography.

Authors:  Valentina Giacometti; Raymond B King; Christina E Agnew; Denise M Irvine; Suneil Jain; Alan R Hounsell; Conor K McGarry
Journal:  Br J Radiol       Date:  2019-02-26       Impact factor: 3.039

5.  Utility and validation of biomechanical deformable image registration in low-contrast images.

Authors:  Michael Velec; Titania Juang; Joanne L Moseley; Mark Oldham; Kristy K Brock
Journal:  Pract Radiat Oncol       Date:  2015-03-29

6.  Adaptive Radiotherapy: Moving Into the Future.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2019-07       Impact factor: 5.934

7.  Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections.

Authors:  You Zhang; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

8.  Magnetic Resonance-Guided Stereotactic Body Radiotherapy of Liver Tumors: Initial Clinical Experience and Patient-Reported Outcomes.

Authors:  Fabian Weykamp; Philipp Hoegen; Sebastian Klüter; C Katharina Spindeldreier; Laila König; Katharina Seidensaal; Sebastian Regnery; Jakob Liermann; Carolin Rippke; Stefan A Koerber; Carolin Buchele; Jürgen Debus; Juliane Hörner-Rieber
Journal:  Front Oncol       Date:  2021-06-09       Impact factor: 6.244

9.  Analysis of using high-precision radiotherapy in the treatment of liver metastases regarding toxicity and survival.

Authors:  Theresa Voglhuber; Kerstin A Eitz; Markus Oechsner; Marco M E Vogel; Stephanie E Combs
Journal:  BMC Cancer       Date:  2021-07-06       Impact factor: 4.430

10.  Evaluation of dosimetric misrepresentations from 3D conventional planning of liver SBRT using 4D deformable dose integration.

Authors:  Unjin A Yeo; Michael L Taylor; Jeremy R Supple; Shankar Siva; Tomas Kron; Daniel Pham; Rick D Franich
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.