MR-compatible treadmill for exercise stress cardiac magnetic resonance imaging.

Eric L Foster1, John W Arnold, Mihaela Jekic, Jacob A Bender, Vijay Balasubramanian, Paaladinesh Thavendiranathan, Jennifer A Dickerson, Subha V Raman, Orlando P Simonetti.   

Abstract

This article describes an MR-safe treadmill that enables cardiovascular exercise stress testing adjacent to the MRI system, facilitating cardiac MR imaging immediately following exercise stress. The treadmill was constructed of nonferromagnetic components utilizing a hydraulic power system. Computer control ensured precise execution of the standard Bruce treadmill protocol commonly used for cardiovascular exercise stress testing. The treadmill demonstrated no evidence of ferromagnetic attraction and did not affect image quality. Treadmill performance met design specifications both inside and outside the MRI environment. Ten healthy volunteers performed the Bruce protocol with the treadmill positioned adjacent to the MRI table. Upon reaching peak stress (98 ± 8% of age-predicted maximum heart rate), the subjects lay down directly on the MRI table, a cardiac array coil was placed, an intravenous line connected, and stress cine and perfusion imaging performed. Cine imaging commenced on average within 24 ± 4 s and was completed within 40 ± 7 s of the end of exercise. Subject heart rates were 86 ± 9% of age-predicted maximum heart rate at the start of imaging and 81 ± 9% of age-predicted maximum heart rate upon completion of cine imaging. The MRI-compatible treadmill was shown to operate safely and effectively in the MRI environment.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22190228      PMCID: PMC3288792          DOI: 10.1002/mrm.23059

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Quantitative abdominal aortic flow measurements at controlled levels of ergometer exercise.

Authors:  E M Pedersen; S Kozerke; S Ringgaard; M B Scheidegger; P Boesiger
Journal:  Magn Reson Imaging       Date:  1999-05       Impact factor: 2.546

2.  Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging.

Authors:  Igor Klem; John F Heitner; Dipan J Shah; Michael H Sketch; Victor Behar; Jonathan Weinsaft; Peter Cawley; Michele Parker; Michael Elliott; Robert M Judd; Raymond J Kim
Journal:  J Am Coll Cardiol       Date:  2006-03-27       Impact factor: 24.094

3.  EXERCISING TESTING IN ADULT NORMAL SUBJECTS AND CARDIAC PATIENTS.

Authors:  R A BRUCE; J R BLACKMON; J W JONES; G STRAIT
Journal:  Pediatrics       Date:  1963-10       Impact factor: 7.124

4.  Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA).

Authors:  Felix A Breuer; Peter Kellman; Mark A Griswold; Peter M Jakob
Journal:  Magn Reson Med       Date:  2005-04       Impact factor: 4.668

5.  Measurement of aortic and pulmonary flow with MRI at rest and during physical exercise.

Authors:  R A Niezen; J Doornbos; E E van der Wall; A de Roos
Journal:  J Comput Assist Tomogr       Date:  1998 Mar-Apr       Impact factor: 1.826

Review 6.  Treadmill exercise echocardiography: methodology and clinical role.

Authors:  W F Armstrong
Journal:  Eur Heart J       Date:  1997-06       Impact factor: 29.983

7.  Relationship between exercise echocardiography and perfusion single-photon emission computed tomography in patients with single-vessel coronary artery disease.

Authors:  A Salustri; M M Pozzoli; W Hermans; B Ilmer; J H Cornel; A E Reijs; J R Roelandt; P M Fioretti
Journal:  Am Heart J       Date:  1992-07       Impact factor: 4.749

8.  Peak exercise and immediate postexercise imaging for the detection of left ventricular functional abnormalities in coronary artery disease.

Authors:  D S Dymond; C Foster; R P Grenier; J Carpenter; D H Schmidt
Journal:  Am J Cardiol       Date:  1984-06-01       Impact factor: 2.778

9.  Comparison of postexercise and transesophageal atrial pacing two-dimensional echocardiography for detection of coronary artery disease.

Authors:  S Iliceto; G D'Ambrosio; M Sorino; A Papa; A Amico; A Ricci; P Rizzon
Journal:  Am J Cardiol       Date:  1986-03-01       Impact factor: 2.778

10.  Clinical application of exercise stress echocardiography: supine bicycle or treadmill?

Authors:  A Dagianti; M Penco; A Bandiera; L Sgorbini; F Fedele
Journal:  Am J Cardiol       Date:  1998-06-18       Impact factor: 2.778

View more
  18 in total

Review 1.  Advances in stress cardiac MRI and computed tomography.

Authors:  Yasmin S Hamirani; Christopher M Kramer
Journal:  Future Cardiol       Date:  2013-09

2.  Comparison of treadmill exercise stress cardiac MRI to stress echocardiography in healthy volunteers for adequacy of left ventricular endocardial wall visualization: A pilot study.

Authors:  Paaladinesh Thavendiranathan; Jennifer A Dickerson; Debbie Scandling; Vijay Balasubramanian; Michael L Pennell; Alice Hinton; Subha V Raman; Orlando P Simonetti
Journal:  J Magn Reson Imaging       Date:  2013-10-10       Impact factor: 4.813

3.  Free-breathing cardiac MR stress perfusion with real-time slice tracking.

Authors:  Tamer A Basha; Sébastien Roujol; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

Review 4.  Exercise cardiac magnetic resonance imaging: a feasibility study and meta-analysis.

Authors:  Rhys I Beaudry; T Jake Samuel; Jing Wang; Wesley J Tucker; Mark J Haykowsky; Michael D Nelson
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2018-06-27       Impact factor: 3.619

Review 5.  Athlete's Heart: Diagnostic Challenges and Future Perspectives.

Authors:  Carlo De Innocentiis; Fabrizio Ricci; Mohammed Y Khanji; Nay Aung; Claudio Tana; Elvira Verrengia; Steffen E Petersen; Sabina Gallina
Journal:  Sports Med       Date:  2018-11       Impact factor: 11.136

6.  A Magnetic Resonance Imaging-Conditional External Cardiac Defibrillator for Resuscitation Within the Magnetic Resonance Imaging Scanner Bore.

Authors:  Ehud J Schmidt; Ronald D Watkins; Menekhem M Zviman; Michael A Guttman; Wei Wang; Henry A Halperin
Journal:  Circ Cardiovasc Imaging       Date:  2016-10       Impact factor: 7.792

7.  Feasibility and reproducibility of a cardiovascular magnetic resonance free-breathing, multi-shot, navigated image acquisition technique for ventricular volume quantification during continuous exercise.

Authors:  Pei G Chew; Peter P Swoboda; Carrie Ferguson; Pankaj Garg; Abigail L Cook; Said Ibeggazene; Louise A E Brown; Thomas P Craven; James R Foley; Graham J Fent; Christopher E Saunderson; David M Higgins; Sven Plein; Karen M Birch; John P Greenwood
Journal:  Quant Imaging Med Surg       Date:  2020-09

Review 8.  Cardiac MRI: a Translational Imaging Tool for Characterizing Anthracycline-Induced Myocardial Remodeling.

Authors:  Kim-Lien Nguyen; Peng Hu; Daniel B Ennis; Jiaxin Shao; Kimberly A Pham; Joseph J Chen
Journal:  Curr Oncol Rep       Date:  2016-08       Impact factor: 5.075

9.  Rapid assessment of quantitative T1, T2 and T2* in lower extremity muscles in response to maximal treadmill exercise.

Authors:  Juliet Varghese; Debbie Scandling; Rohit Joshi; Ashish Aneja; Jason Craft; Subha V Raman; Sanjay Rajagopalan; Orlando P Simonetti; Georgeta Mihai
Journal:  NMR Biomed       Date:  2015-06-28       Impact factor: 4.044

10.  Feasibility of Cardiovascular Four-dimensional Flow MRI during Exercise in Healthy Participants.

Authors:  Jacob A Macdonald; Arij G Beshish; Philip A Corrado; Gregory P Barton; Kara N Goss; Marlowe W Eldridge; Christopher J François; Oliver Wieben
Journal:  Radiol Cardiothorac Imaging       Date:  2020-06-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.