Quantitative abdominal aortic flow measurements at controlled levels of ergometer exercise.

E M Pedersen1, S Kozerke, S Ringgaard, M B Scheidegger, P Boesiger.   

Abstract

Measuring the exercise-induced flow changes in the arteries of the body is a major challenge. The use of quantitative MR flow measurements for this purpose is hampered by movement artifacts and ECG triggering problems. To quantify exercise-induced flow changes in the abdominal aorta, we applied a fast hybrid phase contrast sequence with K-space segmentation and echo planar imaging readouts during a 12 heart beat, single breathhold post exercise scanning window after ergometer exercise in nine volunteers. Central k-space was acquired first. The changes in heart rate throughout the scanning window were quantified. The mean decrease in heart rate after six heart beats post exercise was less than 4% and less than 14% after 11 heart beats indicating that the exercise state was very well represented during the acquisition of central k-space. Abdominal aortic flow increased from 1.4+/-0.3 l/min at rest to 7.9+/-1.1 l/min at 131 watt. Retrograde flow reached a maximum value of 1.2 l/min at rest, and lasted 140 ms on average. Only for one out of the nine volunteers was there any retrograde flow present during exercise (at 33 watt and 65 watt exercise). It was concluded that retrograde flow patterns in the abdominal aorta associated with oscillating wall shear stresses and development of atherosclerosis disappeared with increasing levels of exercise. The feasibility of using fast quantitative phase contrast measurements during a post exercise scanning window to represent controlled exercise levels was demonstrated.

Entities:  

Mesh:

Year:  1999        PMID: 10231175     DOI: 10.1016/s0730-725x(98)00209-4

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  12 in total

Review 1.  Hemodynamic influences on abdominal aortic aneurysm disease: Application of biomechanics to aneurysm pathophysiology.

Authors:  Monica M Dua; Ronald L Dalman
Journal:  Vascul Pharmacol       Date:  2010-03-25       Impact factor: 5.773

2.  Routine use of an aortic balloon to resolve possible inflow stenosis induced by the inflatable ring fixation mechanism of the Ovation endograft.

Authors:  Christos V Ioannou; Nikolaos Kontopodis; Efstratios Georgakarakos; Elias Kehagias; Eleni Metaxa; Stella Lioudaki; Yannis Papaharilaou; Dimitrios Tsetis
Journal:  Radiol Med       Date:  2016-07-23       Impact factor: 3.469

3.  Shared velocity encoding: a method to improve the temporal resolution of phase-contrast velocity measurements.

Authors:  Hung-Yu Lin; Jacob A Bender; Yu Ding; Yiu-Cho Chung; Alice M Hinton; Michael L Pennell; Kevin K Whitehead; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

4.  MR-compatible treadmill for exercise stress cardiac magnetic resonance imaging.

Authors:  Eric L Foster; John W Arnold; Mihaela Jekic; Jacob A Bender; Vijay Balasubramanian; Paaladinesh Thavendiranathan; Jennifer A Dickerson; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2011-08-16       Impact factor: 4.668

5.  Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping.

Authors:  E M Pedersen; E V Stenbøg; T Fründ; K Houlind; O Kromann; K E Sørensen; K Emmertsen; V E Hjortdal
Journal:  Heart       Date:  2002-06       Impact factor: 5.994

6.  Cardiovascular response to physical exercise in adult patients after atrial correction for transposition of the great arteries assessed with magnetic resonance imaging.

Authors:  A A W Roest; H J Lamb; E E van der Wall; H W Vliegen; J G van den Aardweg; P Kunz; A de Roos; W A Helbing
Journal:  Heart       Date:  2004-06       Impact factor: 5.994

7.  Toward translating near-infrared spectroscopy oxygen saturation data for the non-invasive prediction of spatial and temporal hemodynamics during exercise.

Authors:  Laura Ellwein; Margaret M Samyn; Michael Danduran; Sheila Schindler-Ivens; Stacy Liebham; John F LaDisa
Journal:  Biomech Model Mechanobiol       Date:  2016-07-04

8.  Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis.

Authors:  Nicolas Aristokleous; Nikolaos G Kontopodis; Konstantinos Tzirakis; Christos V Ioannou; Yannis Papaharilaou
Journal:  Med Biol Eng Comput       Date:  2015-12-16       Impact factor: 2.602

9.  Isometric stress in cardiovascular magnetic resonance-a simple and easily replicable method of assessing cardiovascular differences not apparent at rest.

Authors:  Kristian H Mortensen; Alexander Jones; Jennifer A Steeden; Andrew M Taylor; Vivek Muthurangu
Journal:  Eur Radiol       Date:  2015-07-24       Impact factor: 5.315

10.  Design and testing of an MRI-compatible cycle ergometer for non-invasive cardiac assessments during exercise.

Authors:  Silmara Gusso; Carlo Salvador; Paul Hofman; Wayne Cutfield; James C Baldi; Andrew Taberner; Poul Nielsen
Journal:  Biomed Eng Online       Date:  2012-03-18       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.