Literature DB >> 22187628

Neurologic 3D MR spectroscopic imaging with low-power adiabatic pulses and fast spiral acquisition.

Ovidiu C Andronesi1, Borjan A Gagoski, A Gregory Sorensen.   

Abstract

PURPOSE: To improve clinical three-dimensional (3D) MR spectroscopic imaging with more accurate localization and faster acquisition schemes.
MATERIALS AND METHODS: Institutional review board approval and patient informed consent were obtained. Data were acquired with a 3-T MR imager and a 32-channel head coil in phantoms, five healthy volunteers, and five patients with glioblastoma. Excitation was performed with localized adiabatic spin-echo refocusing (LASER) by using adiabatic gradient-offset independent adiabaticity wideband uniform rate and smooth truncation (GOIA-W[16,4]) pulses with 3.5-msec duration, 20-kHz bandwidth, 0.81-kHz amplitude, and 45-msec echo time. Interleaved constant-density spirals simultaneously encoded one frequency and two spatial dimensions. Conventional phase encoding (PE) (1-cm3 voxels) was performed after LASER excitation and was the reference standard. Spectra acquired with spiral encoding at similar and higher spatial resolution and with shorter imaging time were compared with those acquired with PE. Metabolite levels were fitted with software, and Bland-Altman analysis was performed.
RESULTS: Clinical 3D MR spectroscopic images were acquired four times faster with spiral protocols than with the elliptical PE protocol at low spatial resolution (1 cm3). Higher-spatial-resolution images (0.39 cm3) were acquired twice as fast with spiral protocols compared with the low-spatial-resolution elliptical PE protocol. A minimum signal-to-noise ratio (SNR) of 5 was obtained with spiral protocols under these conditions and was considered clinically adequate to reliably distinguish metabolites from noise. The apparent SNR loss was not linear with decreasing voxel sizes because of longer local T2* times. Improvement of spectral line width from 4.8 Hz to 3.5 Hz was observed at high spatial resolution. The Bland-Altman agreement between spiral and PE data is characterized by narrow 95% confidence intervals for their differences (0.12, 0.18 of their means). GOIA-W(16,4) pulses minimize chemical-shift displacement error to 2.1%, reduce nonuniformity of excitation to 5%, and eliminate the need for outer volume suppression.
CONCLUSION: The proposed adiabatic spiral 3D MR spectroscopic imaging sequence can be performed in a standard clinical MR environment. Improvements in image quality and imaging time could enable more routine acquisition of spectroscopic data than is possible with current pulse sequences. © RSNA, 2011

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22187628      PMCID: PMC3267083          DOI: 10.1148/radiol.11110277

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  48 in total

1.  Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer.

Authors:  T K Tran; D B Vigneron; N Sailasuta; J Tropp; P Le Roux; J Kurhanewicz; S Nelson; R Hurd
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  Assessment of 3D proton MR echo-planar spectroscopic imaging using automated spectral analysis.

Authors:  A Ebel; B J Soher; A A Maudsley
Journal:  Magn Reson Med       Date:  2001-12       Impact factor: 4.668

3.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

Authors:  M Garwood; L DelaBarre
Journal:  J Magn Reson       Date:  2001-12       Impact factor: 2.229

4.  Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy.

Authors:  Andreas Ebel; Andrew A Maudsley
Journal:  Magn Reson Imaging       Date:  2003-02       Impact factor: 2.546

5.  Proton echo-planar spectroscopic imaging with highly effective outer volume suppression using combined presaturation and spatially selective echo dephasing.

Authors:  Archie Chu; Jeffry R Alger; Gregory J Moore; Stefan Posse
Journal:  Magn Reson Med       Date:  2003-05       Impact factor: 4.668

6.  Comparison of inversion recovery preparation schemes for lipid suppression in 1H MRSI of human brain.

Authors:  Andreas Ebel; Varanavasi Govindaraju; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2003-05       Impact factor: 4.668

Review 7.  Multivoxel magnetic resonance spectroscopy of brain tumors.

Authors:  Sarah J Nelson
Journal:  Mol Cancer Ther       Date:  2003-05       Impact factor: 6.261

8.  Automatic placement of outer volume suppression slices in MR spectroscopic imaging of the human brain.

Authors:  Manel Martínez-Ramón; Ascensión Gallardo-Antolín; Jesús Cid-Sueiro; Gregory L Heileman; Kaung-Ti Yung; Weili Zheng; Chenguang Zhao; Stefan Posse
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

9.  High-resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy-matched voxel sizes.

Authors:  Stephan Gruber; Vladimir Mlynárik; Ewald Moser
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

10.  Gray matter N-acetyl aspartate deficits in secondary progressive but not relapsing-remitting multiple sclerosis.

Authors:  Elfar Adalsteinsson; Annette Langer-Gould; Ronald J Homer; Archana Rao; Edith V Sullivan; Christiane Abbehusen Lima; Adolf Pfefferbaum; Scott W Atlas
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

View more
  35 in total

1.  Comparison of accelerated 3-D spiral chemical shift imaging and single-voxel spectroscopy at 3T in the pediatric age group.

Authors:  Sandrine Yazbek; Sanjay P Prabhu; Pauline Connaughton; Patricia E Grant; Borjan Gagoski
Journal:  Pediatr Radiol       Date:  2015-04-01

2.  Ultrafast magnetic resonance spectroscopic imaging using SPICE with learned subspaces.

Authors:  Fan Lam; Yudu Li; Rong Guo; Bryan Clifford; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

3.  Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.

Authors:  Chao Ma; Fan Lam; Curtis L Johnson; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

Review 4.  Strategies for rapid in vivo 1H and hyperpolarized 13C MR spectroscopic imaging.

Authors:  Sarah J Nelson; Eugene Ozhinsky; Yan Li; Il woo Park; Jason Crane
Journal:  J Magn Reson       Date:  2013-02-08       Impact factor: 2.229

5.  Short-echo three-dimensional H-1 MR spectroscopic imaging of patients with glioma at 7 Tesla for characterization of differences in metabolite levels.

Authors:  Yan Li; Peder Larson; Albert P Chen; Janine M Lupo; Eugene Ozhinsky; Douglas Kelley; Susan M Chang; Sarah J Nelson
Journal:  J Magn Reson Imaging       Date:  2014-06-17       Impact factor: 4.813

6.  Fast 3D rosette spectroscopic imaging of neocortical abnormalities at 3 T: Assessment of spectral quality.

Authors:  Claudiu V Schirda; Tiejun Zhao; Victor E Yushmanov; Yoojin Lee; Gena R Ghearing; Frank S Lieberman; Ashok Panigrahy; Hoby P Hetherington; Jullie W Pan
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

7.  In vivo brain rosette spectroscopic imaging (RSI) with LASER excitation, constant gradient strength readout, and automated LCModel quantification for all voxels.

Authors:  Claudiu V Schirda; Tiejun Zhao; Ovidiu C Andronesi; Yoojin Lee; Jullie W Pan; James M Mountz; Hoby P Hetherington; Fernando E Boada
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

8.  Impact of reduced k-space acquisition on pathologic detectability for volumetric MR spectroscopic imaging.

Authors:  Mohammad Sabati; Jiping Zhan; Varan Govind; Kristopher L Arheart; Andrew A Maudsley
Journal:  J Magn Reson Imaging       Date:  2013-04-04       Impact factor: 4.813

9.  High-resolution (1) H-MRSI of the brain using SPICE: Data acquisition and image reconstruction.

Authors:  Fan Lam; Chao Ma; Bryan Clifford; Curtis L Johnson; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

10.  Three-dimensional MR spectroscopic imaging using adiabatic spin echo and hypergeometric dual-band suppression for metabolic mapping over the entire brain.

Authors:  Morteza Esmaeili; Tone F Bathen; Bruce R Rosen; Ovidiu C Andronesi
Journal:  Magn Reson Med       Date:  2016-02-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.