Literature DB >> 22178777

The different contributions of cortical and trabecular bone to implant anchorage in a human vertebra.

Davide Ruffoni1, Andreas J Wirth, Juri A Steiner, Ian H Parkinson, Ralph Müller, G Harry van Lenthe.   

Abstract

The quality of the peri-implant bone and the strength of the bone-implant interface are important factors for implant anchorage. With regard to peri-implant bone, cortical and trabecular compartments both contribute to the load transfer from the implant to the surrounding bone but their relative roles have yet to be investigated in detail. However, this knowledge is crucial for the better understanding of implant failure and for the development of new implants. This is especially true for osteoporotic bone, which is characterized by a deterioration of the trabecular architecture and a thinning of the cortical shell, leading to a higher probability of implant loosening. The aim of this study was to investigate the relative biomechanical roles of cortical and trabecular bone on implant pull-out stiffness in human vertebrae. The starting point of our investigation was a micro-computed tomography scan of an adult human vertebra. The cortical shell was identified and an implant was digitally inserted into the vertebral body. Pull-out tests were simulated with micro-finite element analysis and the apparent stiffness of the system with various degrees of shell thickness and bone volume fraction was computed. Our computational models demonstrated that cortical bone, although being very thin, plays a major role in the mechanical competence of the bone-implant construct. Copyright Â
© 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22178777     DOI: 10.1016/j.bone.2011.11.027

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  11 in total

1.  Mechanical regulation of bone formation and resorption around implants in a mouse model of osteopenic bone.

Authors:  Zihui Li; Duncan Betts; Gisela Kuhn; Michael Schirmer; Ralph Müller; Davide Ruffoni
Journal:  J R Soc Interface       Date:  2019-03-29       Impact factor: 4.118

2.  Influence of the shape of the micro-finite element model on the mechanical properties calculated from micro-finite element analysis.

Authors:  Xin-Xin Wen; Hai-Long Yu; Ya-Bo Yan; Chun-Lin Zong; Hai-Jiao Ding; Xiang-Yu Ma; Tian-Sheng Wang; Wei Lei
Journal:  Exp Ther Med       Date:  2017-06-28       Impact factor: 2.447

3.  Measuring the thickness of vertebral endplate and shell using digital tomosynthesis.

Authors:  Yener N Yeni; Michael R Dix; Angela Xiao; Daniel J Oravec; Michael J Flynn
Journal:  Bone       Date:  2022-01-28       Impact factor: 4.398

Review 4.  Pharmacologic augmentation of implant fixation in osteopenic bone.

Authors:  R D Ross; J L Hamilton; B M Wilson; D R Sumner; A S Virdi
Journal:  Curr Osteoporos Rep       Date:  2014-03       Impact factor: 5.096

5.  Implant surface alters compartmental-specific contributions to fixation strength in rats.

Authors:  Frank C Ko; Matthew J Meagher; Maleeha Mashiatulla; Ryan D Ross; Amarjit S Virdi; Dale R Sumner
Journal:  J Orthop Res       Date:  2019-12-25       Impact factor: 3.494

6.  Time course of peri-implant bone regeneration around loaded and unloaded implants in a rat model.

Authors:  Shailly H Jariwala; Hwabok Wee; Evan P Roush; Tiffany L Whitcomb; Christopher Murter; Gery Kozlansky; Akhlesh Lakhtakia; Allen R Kunselman; Henry J Donahue; April D Armstrong; Gregory S Lewis
Journal:  J Orthop Res       Date:  2016-07-20       Impact factor: 3.494

7.  Impaired bone formation in ovariectomized mice reduces implant integration as indicated by longitudinal in vivo micro-computed tomography.

Authors:  Zihui Li; Gisela Kuhn; Michael Schirmer; Ralph Müller; Davide Ruffoni
Journal:  PLoS One       Date:  2017-09-14       Impact factor: 3.240

Review 8.  A Review and Clinical Perspective of the Impact of Osteoporosis on the Spine.

Authors:  Bayard C Carlson; William A Robinson; Nathan R Wanderman; Arjun S Sebastian; Ahmad Nassr; Brett A Freedman; Paul A Anderson
Journal:  Geriatr Orthop Surg Rehabil       Date:  2019-07-17

9.  Effect of platelet-rich and platelet-poor plasma on 3D bone-to-implant contact: a preclinical micro-CT study.

Authors:  Dandan Song; Sohaib Shujaat; Yan Huang; Jeroen Van Dessel; Constantinus Politis; Ivo Lambrichts; Reinhilde Jacobs
Journal:  Int J Implant Dent       Date:  2021-02-18

Review 10.  Finite Element Analysis of Fracture Fixation.

Authors:  Gregory S Lewis; Dominic Mischler; Hwabok Wee; J Spence Reid; Peter Varga
Journal:  Curr Osteoporos Rep       Date:  2021-06-29       Impact factor: 5.163

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.