Literature DB >> 22178165

Shear wave dispersion measures liver steatosis.

Christopher T Barry1, Bradley Mills, Zaegyoo Hah, Robert A Mooney, Charlotte K Ryan, Deborah J Rubens, Kevin J Parker.   

Abstract

Crawling waves, which are interfering shear wave patterns, can be generated in liver tissue over a range of frequencies. Some important biomechanical properties of the liver can be determined by imaging the crawling waves using Doppler techniques and analyzing the patterns. We report that the dispersion of shear wave velocity and attenuation, that is, the frequency dependence of these parameters, are strongly correlated with the degree of steatosis in a mouse liver model, ex vivo. The results demonstrate the possibility of assessing liver steatosis using noninvasive imaging methods that are compatible with color Doppler scanners and, furthermore, suggest that liver steatosis can be separated from fibrosis by assessing the dispersion or frequency dependence of shear wave propagations.
Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22178165      PMCID: PMC3428716          DOI: 10.1016/j.ultrasmedbio.2011.10.019

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  41 in total

1.  A model for longitudinal and shear wave propagation in viscoelastic media

Authors: 
Journal:  J Acoust Soc Am       Date:  2000-05       Impact factor: 1.840

2.  Relaxation effects in the quantification of fat using gradient echo imaging.

Authors:  Mark Bydder; Takeshi Yokoo; Gavin Hamilton; Michael S Middleton; Alyssa D Chavez; Jeffrey B Schwimmer; Joel E Lavine; Claude B Sirlin
Journal:  Magn Reson Imaging       Date:  2008-02-21       Impact factor: 2.546

Review 3.  Elastography in the management of liver disease.

Authors:  Edwin L Carstensen; Kevin J Parker; Robert M Lerner
Journal:  Ultrasound Med Biol       Date:  2008-05-15       Impact factor: 2.998

4.  Nonalcoholic fatty liver disease: US-based acoustic radiation force impulse elastography.

Authors:  Masato Yoneda; Kaori Suzuki; Shingo Kato; Koji Fujita; Yuichi Nozaki; Kunihiro Hosono; Satoru Saito; Atsushi Nakajima
Journal:  Radiology       Date:  2010-06-07       Impact factor: 11.105

5.  Prospective evaluation of the diagnostic accuracy of liver ultrasonography.

Authors:  J C Debongnie; C Pauls; M Fievez; E Wibin
Journal:  Gut       Date:  1981-02       Impact factor: 23.059

6.  In vivo quantification of liver stiffness in a rat model of hepatic fibrosis with acoustic radiation force.

Authors:  Michael H Wang; Mark L Palmeri; Cynthia D Guy; Liu Yang; Laurence W Hedlund; Anna Mae Diehl; Kathryn R Nightingale
Journal:  Ultrasound Med Biol       Date:  2009-08-14       Impact factor: 2.998

7.  Liver biopsy findings from healthy potential living liver donors: reasons for disqualification, silent diseases and correlation with liver injury tests.

Authors:  Marta I Minervini; Kristine Ruppert; Paulo Fontes; Riccardo Volpes; Giovanni Vizzini; Michael E de Vera; Salvatore Gruttadauria; Roberto Miraglia; Loredana Pipitone; J Wallis Marsh; Amadeo Marcos; Bruno Gridelli; Anthony J Demetris
Journal:  J Hepatol       Date:  2008-12-29       Impact factor: 25.083

8.  Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging.

Authors:  Mickael Tanter; Jeremy Bercoff; Alexandra Athanasiou; Thomas Deffieux; Jean-Luc Gennisson; Gabriel Montaldo; Marie Muller; Anne Tardivon; Mathias Fink
Journal:  Ultrasound Med Biol       Date:  2008-04-08       Impact factor: 2.998

9.  A rapid and reliable means of assessing hepatic steatosis in vivo via electrical bioimpedance.

Authors:  Amelia J Hessheimer; Damià Parramón; Anton Guimerà; Ivan Erill; Antoni Rimola; Juan C García-Valdecasas; Rosa Villa; Constantino Fondevila
Journal:  Transplantation       Date:  2009-09-15       Impact factor: 4.939

Review 10.  Hepatocellular carcinoma with nonalcoholic steatohepatitis.

Authors:  Sayaka Mori; Takahiro Yamasaki; Isao Sakaida; Taro Takami; Eiki Sakaguchi; Teruaki Kimura; Fumie Kurokawa; Shiro Maeyama; Kiwamu Okita
Journal:  J Gastroenterol       Date:  2004       Impact factor: 7.527

View more
  24 in total

1.  Assessment of Structural Heterogeneity and Viscosity in the Cervix Using Shear Wave Elasticity Imaging: Initial Results from a Rhesus Macaque Model.

Authors:  Ivan M Rosado-Mendez; Mark L Palmeri; Lindsey C Drehfal; Quinton W Guerrero; Heather Simmons; Helen Feltovich; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2017-02-08       Impact factor: 2.998

2.  Elasticity mapping of murine abdominal organs in vivo using harmonic motion imaging (HMI).

Authors:  Thomas Payen; Carmine F Palermo; Stephen A Sastra; Hong Chen; Yang Han; Kenneth P Olive; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2016-07-12       Impact factor: 3.609

3.  The Gaussian shear wave in a dispersive medium.

Authors:  Kevin J Parker; Natalie Baddour
Journal:  Ultrasound Med Biol       Date:  2014-01-10       Impact factor: 2.998

Review 4.  MR elastography of liver: current status and future perspectives.

Authors:  Ilkay S Idilman; Jiahui Li; Meng Yin; Sudhakar K Venkatesh
Journal:  Abdom Radiol (NY)       Date:  2020-07-23

5.  Measurement of Liver Stiffness Using Shear Wave Elastography in a Rat Model: Factors Impacting Stiffness Measurement with Multiple- and Single-Tracking-Location Techniques.

Authors:  Jonathan H Langdon; Etana Elegbe; Raul S Gonzalez; Laurentius Osapoetra; Tristan Ford; Stephen A McAleavey
Journal:  Ultrasound Med Biol       Date:  2017-08-19       Impact factor: 2.998

Review 6.  Advances in Magnetic Resonance Elastography of Liver.

Authors:  Jiahui Li; Sudhakar Kundapur Venkatesh; Meng Yin
Journal:  Magn Reson Imaging Clin N Am       Date:  2020-06-06       Impact factor: 2.266

7.  Analyzing and modeling rheological behavior of liver fibrosis in rats using shear viscoelastic moduli.

Authors:  Ying Zhu; Yi Zheng; Yuan-yuan Shen; Xin Chen; Xin-yu Zhang; Hao-ming Lin; Yan-rong Guo; Tian-fu Wang; Si-ping Chen
Journal:  J Zhejiang Univ Sci B       Date:  2014-04       Impact factor: 3.066

8.  Distinguishing between Hepatic Inflammation and Fibrosis with MR Elastography.

Authors:  Meng Yin; Kevin J Glaser; Armando Manduca; Taofic Mounajjed; Harmeet Malhi; Douglas A Simonetto; Ruisi Wang; Liu Yang; Shennen A Mao; Jaime M Glorioso; Faysal M Elgilani; Christopher J Ward; Peter C Harris; Scott L Nyberg; Vijay H Shah; Richard L Ehman
Journal:  Radiology       Date:  2017-01-27       Impact factor: 11.105

9.  Guidelines for Finite-Element Modeling of Acoustic Radiation Force-Induced Shear Wave Propagation in Tissue-Mimicking Media.

Authors:  Mark L Palmeri; Bo Qiang; Shigao Chen; Matthew W Urban
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-12-21       Impact factor: 2.725

10.  Assessment of liver viscoelasticity by using shear waves induced by ultrasound radiation force.

Authors:  Shigao Chen; William Sanchez; Matthew R Callstrom; Brian Gorman; Jason T Lewis; Schuyler O Sanderson; James F Greenleaf; Hua Xie; Yan Shi; Michael Pashley; Vijay Shamdasani; Michael Lachman; Stephen Metz
Journal:  Radiology       Date:  2012-12-06       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.