The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measurements by combining the Si-PM-based PET and the 0.15 T permanent MRI to test the interferences between the Si-PM-based PET and an MRI. When the Si-PM was inside the MRI and installed around the radio frequency (RF) coil of the MRI, significant noise from the RF sequence of the MRI was observed in the analog signals of the PET detectors. However, we did not observe any artifacts in the PET images; fluctuation increased in the count rate of the Si-PM-based PET system. On the MRI side, there was significant degradation of the signal-to-noise ratio (S/N) in the MRI images compared with those without PET. By applying noise reduction procedures, the degradation of the S/N was reduced. With this condition, simultaneous measurements of a rat brain using a Si-PM-based PET and an MRI were made with some degradation in the MRI images. We conclude that simultaneous measurements are possible using Si-PM-based PET and MRI.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22170810     DOI: 10.1088/0031-9155/57/2/N1

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

Review 1.  Use of Breast-Specific PET Scanners and Comparison with MR Imaging.

Authors:  Deepa Narayanan; Wendie A Berg
Journal:  Magn Reson Imaging Clin N Am       Date:  2018-05       Impact factor: 2.266

2.  Development of 1.45-mm resolution four-layer DOI-PET detector for simultaneous measurement in 3T MRI.

Authors:  Fumihiko Nishikido; Atsushi Tachibana; Takayuki Obata; Naoko Inadama; Eiji Yoshida; Mikio Suga; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2014-10-28

Review 3.  Quantitative Rodent Brain Receptor Imaging.

Authors:  Kristina Herfert; Julia G Mannheim; Laura Kuebler; Sabina Marciano; Mario Amend; Christoph Parl; Hanna Napieczynska; Florian M Maier; Salvador Castaneda Vega; Bernd J Pichler
Journal:  Mol Imaging Biol       Date:  2020-04       Impact factor: 3.488

4.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

Review 5.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

6.  Performance Comparison of Different Readouts for Position-Sensitive Solid-State Photomultiplier Arrays.

Authors:  Junwei Du; Jeffrey P Schmall; Kun Di; Yongfeng Yang; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Biomed Phys Eng Express       Date:  2017-07-19

7.  Performance study of a radio-frequency field-penetrable PET insert for simultaneous PET/MRI.

Authors:  Chen-Ming Chang; Brian J Lee; Alexander M Grant; Andrew N Groll; Craig S Levin
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-07-03

Review 8.  Principles of Simultaneous PET/MR Imaging.

Authors:  Ciprian Catana
Journal:  Magn Reson Imaging Clin N Am       Date:  2017-05       Impact factor: 2.266

9.  Readout strategy of an electro-optical coupled PET detector for time-of-flight PET/MRI.

Authors:  M F Bieniosek; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2013-09-24       Impact factor: 3.609

10.  FPGA-based RF interference reduction techniques for simultaneous PET-MRI.

Authors:  P Gebhardt; J Wehner; B Weissler; R Botnar; P K Marsden; V Schulz
Journal:  Phys Med Biol       Date:  2016-04-06       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.