| Literature DB >> 22163542 |
Daniel Tik-Pui Fong1, Yue-Yan Chan.
Abstract
Wearable motion sensors consisting of accelerometers, gyroscopes and magnetic sensors are readily available nowadays. The small size and low production costs of motion sensors make them a very good tool for human motions analysis. However, data processing and accuracy of the collected data are important issues for research purposes. In this paper, we aim to review the literature related to usage of inertial sensors in human lower limb biomechanics studies. A systematic search was done in the following search engines: ISI Web of Knowledge, Medline, SportDiscus and IEEE Xplore. Thirty nine full papers and conference abstracts with related topics were included in this review. The type of sensor involved, data collection methods, study design, validation methods and its applications were reviewed.Entities:
Keywords: accelerometers; gyroscopes; inertial sensors; joint kinematics; magnetic sensors; motion analysis
Mesh:
Year: 2010 PMID: 22163542 PMCID: PMC3231075 DOI: 10.3390/s101211556
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1.Research method of this study.
Type of sensors adopted in reviewed studies.
| Cooper 2009 [ | 1 | triaxial | triaxial | 100 Hz | |||
| Coley 2005 [ | 1 | uniaxial | 30 × 30 × 30 mm3 | ||||
| Willemsen 1991 [ | 16 | uniaxial | 500 Hz | ||||
| Heyn 1996 [ | 8 | uniaxial | 100 Hz | ||||
| O’Donovan 2007 [ | 2 | triaxial | triaxial | triaxial | 60 × 40 × 24 mm3 | 500 Hz | |
| Favre 2008 [ | 2 | triaxial | triaxial | triaxial | 30 × 25 × 25 mm3 | 200 Hz | |
| Favre 2006 [ | 2 | triaxial | triaxial | triaxial | |||
| Cutti [ | 10 | triaxial | triaxial | triaxial | 39 × 54 × 28 mm3 | 38 g | |
| Van den Noort 2009 [ | 2 | triaxial | triaxial | triaxial | 100 Hz | ||
| Kawano 2007 [ | 2 | triaxial | triaxial | triaxial | 53 × 38 × 21 mm3 | 100 Hz | |
| Kawano 2008 [ | 2 | triaxial | triaxial | triaxial | 53 × 38 × 21 mm3 | 30 g | 200 Hz |
| Zijlstra 2008 [ | 2 | triaxial | triaxial | 64 × 62 × 26 mm3 | 150 g | ||
| Andrews 2000 [ | 1 | uniaxial | 18.2 g | ||||
| Avor 2009 [ | 4 | triaxial | triaxial | ||||
| Chan 2010 [ | 1 | triaxial | triaxial | 20 × 18 × 6 mm3 | 500 Hz | ||
| Dejnabadi 2005 [ | 2 | biaxial | uniaxial | 20 × 20 × 10 mm3 | 200 Hz | ||
| Dejnabadi 2006 [ | 4 | biaxial | uniaxial | 20 × 20 × 10 mm3 | |||
| Ermes 2008 [ | 3 | 2 triaxial | 1 triaxial | 20 Hz | |||
| Favre 2009 [ | 2 | triaxial | triaxial | triaxial | 240 Hz | ||
| Findlow 2008 [ | 2 | triaxial | triaxial | 54 × 39 × 28 mm3 | |||
| Hanlon 2009 [ | 2 | biaxial | 200 Hz | ||||
| Helot 2005 [ | 2 | triaxial | triaxial | 100 Hz | |||
| Kendell 2009 [ | 3 | triaxial | triaxial | triaxial | |||
| Lau 2009 [ | 2 | biaxial | uniaxial | 20 × 10 × 10 mm3 | |||
| L’Hemette 2008 [ | 1 | triaxial | 700 g | 100 Hz | |||
| Liu 2008 [ | 2 | triaxial | |||||
| Liu 2009 [ | 3 | triaxial | |||||
| Mamizuka 2007 [ | 1 | triaxial | |||||
| Mayagoitia 2002 [ | 8 | uniaxial | 100 Hz | ||||
| Picemo [ | 4 | triaxial | triaxial | triaxial | |||
| Saber-Sheikh 2010 [ | 2 | triaxial | triaxial | triaxial | 53 × 38 × 21 mm3 | 30 g | |
| Simcox 2005 [ | 3 | 2 biaxial | 1 uniaxial | 70 × 50 × 25 mm3 | 800 Hz | ||
| Tong 1999 [ | 2 | uniaxial | 20 × 10 × 7.2 mm3 | ||||
| Willemsen 1990 [ | 16 | uniaxial | 500 Hz | ||||
| Zhang 2008 [ | 1 | biaxial | |||||
| Ahmadi 2006 [ | 3 | triaxial | 500 Hz | ||||
| Clark 2010 [ | 1 | triaxial | |||||
Motions involved in reviewed studies.
| Cooper 2009 [ | Walking at five speed from 1–5 mi/h |
| Coley 2005 [ | Walking, stair climbing |
| Heyn 1996[ | Walking |
| O’Donovan 2007 [ | Heel and toe rise foot pumps, knee flexion and extension, clockwise and anti-clockwise ankle rotation, lateral and medial foot rotation, eversion and inversion, ambulation |
| Favre 2008 [ | Knee abduction and adduction, 30 m flat walking |
| Favre 2006 [ | Walking |
| Cutti 2010 [ | Walking |
| Music 2008 [ | Sit to stand movement |
| Van den Noort 2009 [ | Clinical assessment of knee joint |
| Zijlstra 2008 [ | Walking |
| Andrews 2000 [ | Landing from a 5 cm fall |
| Avor 2009 [ | Running on treadmill on three different speed |
| Chan 2010 [ | Walking, running, jumping, walking downstairs, cutting, simulated ankle sprain |
| Dejnabadi 2005 [ | Walking level at 3 km/h |
| Ermes 2008 [ | Walking, running, rowing, cycling |
| Favre 2009 [ | Walking |
| Findlow 2008 [ | Walking at self-selected pace |
| Hanlon 2009 [ | Walking |
| Helot 2005 [ | Walking |
| Lau 2009 [ | Walking level, upslope down slope, downstairs, upstairs |
| L’Hemette 2008[ | Walking |
| Liu 2009 [ | Walking at self-selected slow, normal and fast speeds |
| Mamizuka 2007 [ | Knee flexion and extension |
| Mayagoitia 2002 [ | Walking at 1.4 km/h, 2.1 km/h, 2.7 km/h, 3.6 km/h and 4.6 km/h |
| Picemo 2008 [ | Walking |
| Saber-Sheikh 2010 [ | Walking |
| Simcox 2005 [ | Sit-stand-sit, walking |
| Willemsen 1990 [ | Walking |
| Zhang 2008 [ | Walking |
| Ahmadi 2006 [ | Tennis serving |
| Clark 2010 [ | Running on treadmill (10 km/h) |