Literature DB >> 19665712

Functional calibration procedure for 3D knee joint angle description using inertial sensors.

J Favre1, R Aissaoui, B M Jolles, J A de Guise, K Aminian.   

Abstract

Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.

Entities:  

Mesh:

Year:  2009        PMID: 19665712     DOI: 10.1016/j.jbiomech.2009.06.025

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  67 in total

1.  Quadrupedal Locomotion-Respiration Entrainment and Metabolic Economy in Cross-Country Skiers.

Authors:  Kevin Boldt; Anthony Killick; Walter Herzog
Journal:  J Appl Biomech       Date:  2015-08-06       Impact factor: 1.833

2.  Role of body-worn movement monitor technology for balance and gait rehabilitation.

Authors:  Fay Horak; Laurie King; Martina Mancini
Journal:  Phys Ther       Date:  2014-12-11

Review 3.  Wearable knee health system employing novel physiological biomarkers.

Authors:  Omer T Inan; Daniel C Whittingslow; Caitlin N Teague; Sinan Hersek; Maziyar Baran Pouyan; Mindy Millard-Stafford; Geza F Kogler; Michael N Sawka
Journal:  J Appl Physiol (1985)       Date:  2017-07-27

4.  Principal components of wrist circumduction from electromagnetic surgical tracking.

Authors:  Brian J Rasquinha; Michael J Rainbow; Michelle L Zec; David R Pichora; Randy E Ellis
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-07-22       Impact factor: 2.924

5.  Methodological aspects of EEG and body dynamics measurements during motion.

Authors:  Pedro M R Reis; Felix Hebenstreit; Florian Gabsteiger; Vinzenz von Tscharner; Matthias Lochmann
Journal:  Front Hum Neurosci       Date:  2014-03-24       Impact factor: 3.169

6.  Assessing Shoulder Biomechanics of Healthy Elderly Individuals During Activities of Daily Living Using Inertial Measurement Units: High Maximum Elevation Is Achievable but Rarely Used.

Authors:  Ryan M Chapman; Michael T Torchia; John-Erik Bell; Douglas W Van Citters
Journal:  J Biomech Eng       Date:  2019-04-01       Impact factor: 2.097

7.  Validation of Inertial Measurement Units for Upper Body Kinematics.

Authors:  Melissa M B Morrow; Bethany Lowndes; Emma Fortune; Kenton R Kaufman; M Susan Hallbeck
Journal:  J Appl Biomech       Date:  2017-06-26       Impact factor: 1.833

8.  Gait analysis in children with cerebral palsy via inertial and magnetic sensors.

Authors:  Josien C van den Noort; Alberto Ferrari; Andrea G Cutti; Jules G Becher; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2012-12-09       Impact factor: 2.602

9.  A Nonlinear Dynamics-Based Estimator for Functional Electrical Stimulation: Preliminary Results From Lower-Leg Extension Experiments.

Authors:  Marcus Allen; Qiang Zhong; Nicholas Kirsch; Ashwin Dani; William W Clark; Nitin Sharma
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2017-09-07       Impact factor: 3.802

Review 10.  Engineering Aspects of Incidence, Prevalence, and Management of Osteoarthritis: A Review.

Authors:  Dhirendra Kumar Verma; Poonam Kumari; Subramani Kanagaraj
Journal:  Ann Biomed Eng       Date:  2022-01-21       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.