Four-dimensional flow MRI using spiral acquisition.

Andreas Sigfridsson1, Sven Petersson, Carl-Johan Carlhäll, Tino Ebbers.   

Abstract

Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to reduce the scan time of four-dimensional flow MRI without sacrificing quality. Three spiral approaches are presented and evaluated in vivo and in vitro against a conventional Cartesian acquisition. In vivo, the performance of each method was assessed in the thoracic aorta in 10 volunteers using pathline-based analysis and cardiac output analysis. Signal-to-noise ratio and background phase errors were investigated in vitro. Using spiral readouts, the scan times of a four-dimensional flow acquisition of the thoracic aorta could be reduced 2-3-fold, with no statistically significant difference in pathline validity or cardiac output. The shortened scan time improves the applicability of four-dimensional flow MRI, which may allow the technique to become a part of a clinical workflow for cardiovascular functional imaging.
Copyright © 2011 Wiley Periodicals, Inc.

Mesh:

Year:  2011        PMID: 22161650     DOI: 10.1002/mrm.23297

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Fast 4D flow MRI intracranial segmentation and quantification in tortuous arteries.

Authors:  Eric Schrauben; Anders Wåhlin; Khalid Ambarki; Erik Spaak; Jan Malm; Oliver Wieben; Anders Eklund
Journal:  J Magn Reson Imaging       Date:  2015-04-02       Impact factor: 4.813

2.  Highly accelerated aortic 4D flow MR imaging with variable-density random undersampling.

Authors:  Jing Liu; Petter Dyverfeldt; Gabriel Acevedo-Bolton; Michael Hope; David Saloner
Journal:  Magn Reson Imaging       Date:  2014-05-17       Impact factor: 2.546

3.  Volumetric velocity measurements in restricted geometries using spiral sampling: a phantom study.

Authors:  Anders Nilsson; Johan Revstedt; Einar Heiberg; Freddy Ståhlberg; Karin Markenroth Bloch
Journal:  MAGMA       Date:  2014-05-18       Impact factor: 2.310

4.  Dual-Venc acquisition for 4D flow MRI in aortic stenosis with spiral readouts.

Authors:  Sean Callahan; Narayana S Singam; Michael Kendrick; M J Negahdar; Hui Wang; Marcus F Stoddard; Amir A Amini
Journal:  J Magn Reson Imaging       Date:  2019-12-18       Impact factor: 4.813

5.  Accelerated phase contrast flow imaging with direct complex difference reconstruction.

Authors:  Aiqi Sun; Bo Zhao; Ke Ma; Zechen Zhou; Le He; Rui Li; Chun Yuan
Journal:  Magn Reson Med       Date:  2016-03-26       Impact factor: 4.668

6.  Improved respiratory navigator gating for thoracic 4D flow MRI.

Authors:  Pim van Ooij; Edouard Semaan; Susanne Schnell; Shivraman Giri; Zoran Stankovic; James Carr; Alex J Barker; Michael Markl
Journal:  Magn Reson Imaging       Date:  2015-05-02       Impact factor: 2.546

7.  Free-breathing phase contrast MRI with near 100% respiratory navigator efficiency using k-space-dependent respiratory gating.

Authors:  Mehmet Akçakaya; Praveen Gulaka; Tamer A Basha; Long H Ngo; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-07-30       Impact factor: 4.668

8.  Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.

Authors:  Petter Dyverfeldt; Michael D Hope; Elaine E Tseng; David Saloner
Journal:  JACC Cardiovasc Imaging       Date:  2013-01

9.  Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Authors:  Albert Hsiao; Ufra Yousaf; Marcus T Alley; Michael Lustig; Frandics Pak Chan; Beverley Newman; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

10.  4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis.

Authors:  M J Negahdar; Mo Kadbi; Michael Kendrick; Marcus F Stoddard; Amir A Amini
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668