| Literature DB >> 29354720 |
Farideh Doroodgar1, Feazollah Niazi2, Azad Sanginabadi1, Sana Niazi3, Alireza Baradaran-Rafii3, Cyrus Alinia4, Eznollah Azargashb3, Mohammad Ghoreishi5.
Abstract
AIMS: To report on 4-year postoperative visual performance with the toric implantable collamer lens (TICL) for stable keratoconus after sequential procedure (corneal collagen crosslinking plus TICL implantation).Entities:
Keywords: cross-linking; keratoconus; toric implantable collamer lens (TICL)
Year: 2017 PMID: 29354720 PMCID: PMC5721648 DOI: 10.1136/bmjophth-2017-000090
Source DB: PubMed Journal: BMJ Open Ophthalmol ISSN: 2397-3269
Figure 1Eligibility assessment procedure. CDVA, corrected distance visual acuity; CXL, corneal collagen crosslinking; TICL, toric implantable collamer lens.
Preoperative and postoperative demographic data of patients undergoing toric implantable collamer lens surgery after 4 years
| Parameter studied | Outcome |
| Refractive surgery (number of eyes) | 24 patients; 40 eyes (16 patients bilateral, 8 patients unilateral) |
| Mean age±SD | 30.57±4.69 |
| Range | 25–38 |
| Gender | |
| Male | 12 (50%) |
| Female | 12 (50%) |
| Preoperative visual acuity (log MAR) | |
| UCVA | 1.28±0.37 (range: 0.3 to 1.8) |
| CDVA | 0.19±0.11 (range: −0.1 to 0.3) |
| Preoperative refractive error (spherical equivalent) | |
| Range | (−1.75 to −20.50) |
| Mean±SD | (−7.55±4.22) |
| Postoperative visual acuity (log MAR) | |
| UCVA | 0.11±0.13 |
| CDVA | 0.04±0.16 |
| Postoperative residual refraction (D) | |
| Mean±SD | 0.44±0.40 |
CDVA, corrected distance visual acuity; log MAR, logarithm of the minimum angle of resolution; UCVA, uncorrected visual acuity.
Manifest refraction, the toric implantable collamer lens
| Preoperative | Postoperative after 4 years | ||||||
| Cylinder | n/N (%) | Sphere | n/N (%) | Cylinder | n/N (%) | Sphere | n/N (%) |
| ≤−1.50 | 4/40 (10%) | ≤−3.00 | 12/40 (30%) | ≤−1.50 | 36/40 (91.1%) | ±0.25 | 15/40 (37.5%) |
| ≤−3.50 | 20/40 (50%) | ≤−5.00 | 20/40 (50%) | ≤−3.50 | 40/40 (100%) | ±0.50 | 24/40 (60%) |
| ≤−5.00 | 34/40 (85%) | ≤−10.00 | 34/40 (85%) | ≤−5.00 | 40/40 (100%) | ±0.75 | 37/40 (92.5%) |
| ≤−7.00 | 37/40 (92.5%) | ≤−12.00 | 37/40 (92.5%) | ≤−7.00 | 40/40 (100%) | ±1.00 | 39/40 (97.5%) |
| ≤−8.00 | 40/40 (100%) | ≤−18.00 | 40/40 (100%) | ≤−8.00 | 40/40 (100%) | ±1.25 | 40/40 (100%) |
| Mean±SD −3.57±1.56 | Mean±SD −5.06±3.96 | Mean±SD −1.01±0.34 | Mean±SD 0.44±0.38 | ||||
Figure 2A comparison of preoperative best corrected distance visual acuity and postoperative uncorrected distance visual acuity 4 years after toric implantable collamer lens. UCVA, uncorrected visual acuity.
Figure 3Postoperative spherical equivalent during follow-up (1 year and 4 years).
Figure 4Log MAR (logarithm of the minimum angle of resolution) visual acuity defocus curve of +2, +1, 0, −1, −2, −3 and −4 D in a non-cycloplegic condition in the preoperative and postoperative.
Figure 5(A) Contrast sensitivity under mesopic illumination (3 cd/m2). *Statistically significantly different at a level of 0.05. (B) Contrast sensitivity under photopic illumination (85 cd/m2).
Figure 6Total and corneal aberrations in 40 eyes with keratoconus before and after undergoing toric implantable collamer lens surgery. *Statistically significantly different at a level of 0.05. RMS, root mean square,
Figure 7Vectorial display of the difference vector during postoperative follow-up.
Figure 8MTF pre-TICL and post-TICL implantation.
Comparison of vault between each pair
| Value | Change | p Value | |||
| Mean±SD | Range | Mean±SD | Range | ||
| Vault.MONTH1 | 561.18±43.86 | (450, 650) | |||
| Vault.M2 | 644.08±45.45 | (540, 712) | 82.91±55.22 | (−75, 230) | 0.042 |
| Vault.M6 | 672.49±41.79 | (557, 725) | 111.32±54.19 | (−58, 240.3) | <0.001 |
| Vault.Y1 | 658.45±98.22 | (109, 720) | 97.28±100.15 | (−427, 239.3) | <0.001 |
| Vault.Y4 | 641.02±136.31 | (66, 721) | 79.84±143.02 | (−537, 240) | <0.001 |
| Vault.M6_Vault.M2 | 28.41±18.54 | (−2, 62.14) | <0.001 | ||
| Vault.Y1_Vault.M2 | 14.37±101.69 | (−603, 70) | <0.001 | ||
| Vault.Y4_Vault.M2 | −3.06±135.85 | (−602, 71) | <0.001 | ||
| Vault.Y1_Vault.M6 | −14.04±95.23 | (−601, 10) | >0.999 | ||
| Vault.Y4_Vault.M6 | −31.48±131.81 | (−600, 12) | >0.999 | ||
| Vault.Y4_Vault.Y1 | −17.43±94.02 | (−589, 2) | >0.999 | ||
All p values are based on Bonferroni-adjusted comparison between Vault MONTH1 with each other period.
Range: (minimum, maximum).
Peer reviewed publications on the use of TICL for refractive correction in corneal ectasia
| Author(s) year, reference*PubMed, Scopus and science | Number of eyes, follow-up for each procedure | Preoperative data | Postoperative data | Complications | Final outcomes |
| Kamiya | 2 eyes (2 patients), 12 months | Case 1: −10.00–6.00×100 | Case 1: +0.50–1.00×90 | – | – |
| Alfonso | 25 eyes (16 patients), 12 months | Sph: −3.00 to −18.00 D | UCDVA: 0.17±0.19 | – | SI: 1.05 |
| Alfonso | 30 eyes (21 patients), 12 months | Sph: −5.38±3.26 D | Mean UDVA: 0.81±0.20 | – | SI: 1.16 |
| Kamiya | 27 eyes (14 patients), | SER: −10.11±2.46 D | UCDVA: −0.09±0.16 | – | SI: 1.12±0.18 EI: 1.01±0.25 |
| Hashemian | 22 eyes (14 patients), 6 months | Sph: −4.98±2.63 D | Sph: −0.33±0.51 D | – | SI: 1.40±0.32 |
| Kymionis | 1 patient, 3 months | UDVA: C.F | UCVA: 0.3 | – | – |
| Fadlallah | 16 eyes (10 patients), 6 months after CXL, 6 months after TICL | Mean UDVA: 1.67±0.49 | Mean UDVA: 0.17±0.06 | – | SI: 1.08±0.13 |
| Coskunseven | 3 eyes (2 patients). TICL minimum 6 months post-Intacs, 12 months | SE: −18.50±2.61 D | SE: 0.42 D | – | – |
| Fernandez-Vega L | 18 eyes (14 patients), 6 months | UDVA: 0.1±0.05 (decimal) CDVA: 0.7±0.19 (decimal) | UDVA: 0.6±0.19 | – | – |
| Navas | 11 eyes (8 patients), 38.18±18.7 months | SE: −10.52±5.88 D | SE: −0.68±0.45 D | – | SI: 1.28 |
| Coskunseven | 14 eyes (9 patients), 12 months | UDVA: 0.01 (decimal) CDVA: 0.14 (decimal)SE: −16.40±3.56 D | UDVA: 0.44 | – | – |
| Iovieno | 7 eyes (7 patients), 12.8±8.8 months | UCDVA: 1.18±0.4 | UCDVA: 0.2±0.1 | – | – |
| Kurian | 10 eyes (7 patients), 6 months | Mean SE: −7.21±2.25 | Mean SE: −0.44±1.21 D | – | EI: 0.72 |
| Ali M | 29 eyes (16 patients), 3 months | CH: 9.2±1.4 mm Hg | CH: 8.8±1.3 mm Hg | – | – |
| Alió | 20 eyes received an iris claw phakic IOL, and 28 eyes a PC phakic IOL, 36 months | Mean SE: −9.31±4.20 (decimal) | Mean SE: −0.46±0.88 (decimal) | – | – |
| Antonios | 30 eyes (19 patients), 2 years. | UDVA: 1.57±0.56 | UDVA: 0.17±0.06 | – | SI: 1.08±0.13 |
| Kamiya | 21 eyes (11 patients), 3 years | SE: −9.70±2.33 D | UDVA: −0.06±0.11 | – | – |
| Dirani | 11 eyes (7 patients), 6 months | UCVA: 1.47±0.38 log MAR | UCVA: 0.27±0.20 | – | – |
| Kummelil | 10 eyes (7 patients), 6 months | Mean SE: −7.21±2.25 D | Mean SE: −0.44±1.21 D | – | EI: 0.72 |
| Park | Case report, 37-year-old man, 20 months | Refraction: −12.0–3.5×30 | Refraction: −1.75×180 | – | – |
| Camoriano | 10 eyes (5 patients), 3 years | Mean SE: −6.71±0.9 D | SE: −0.58±0.1 D | 1 eye requiring removal and replacement of the toric phakic IOL | – |
| Emara | 11 eyes (9 myopic, 2 hyperopic), 16.8 months (in myopic eyes) | Mean SE: −11.07 D, SE: +8.75 D, CDVA: 20/171 for myopia | Mean SE: −1.40 D | 2 hyperopic eyes | – |
| Prakash | Case report, 35-year-old man | Right UCVA: 4/60 | Refraction: +0.50–0.50×85, UDVA: 6/12, | – | – |
| Alfonso | 40 eyes (31 patients), 6 months | UDVA (decimal): 0.11±0.05 CDVA: 0.56±0.23 | UDVA (decimal): 0.50±0.27 | – | EI: 0.88 |
| Shaheen | 16 eyes (n: 11), 3 years | UDVA: 0.63 | UDVA: 0.88 | – | – |
CDVA, corrected distance visual acuity; CF, Count Fingers; CH, corneal hysteresis; CRF, corneal resistance factor; CXL, corneal collagen crosslinking; Cyl, cylinder; EI, efficacy index; log MAR, logarithm of the minimum angle of resolution; IOL, intra ocular lens; MCDVA, mean corrected distance visual acuity; MUDVA, mean uncorrected distance visual acuity; MSE, manifest spherical equivalent; PC, posterior chamber; SE, spherical equivalent; SER, spherical equivalent refraction; SI, safety index; Sph, sphere; TICL, toric implantable collamer lens; UCDVA, uncorrected distance visual acuity; UCVA, uncorrected visual acuity; UDVA, uncorrected distance visual acuity.