Abstract

PURPOSE: To evaluate the diagnostic accuracy of digital subtraction computed tomographic (CT) angiography in the detection of intracranial aneurysms compared with three-dimensional (3D) rotational digital subtraction angiography (DSA), as reference standard, in a large cohort in a single center.
MATERIALS AND METHODS: The study was waived by the institutional review board because of its retrospective nature. A total of 513 patients clinically suspected of having or with known intracranial aneurysms and other cerebral vascular diseases underwent both digital subtraction CT angiography with a dual-source CT scanner and 3D DSA, with a median interval of 1 day; 436 patients (84.9%) had acute subarachnoid hemorrhage at presentation. The sensitivity, specificity, and accuracy of digital subtraction CT angiography in depicting aneurysm were analyzed on a per-patient and per-aneurysm basis, with 3D DSA as the reference standard. The sensitivity, specificity, and accuracy of digital subtraction CT angiography in depicting aneurysms of different diameter (ie, <3 mm, 3-5 mm, 5-10 mm, and >10 mm) and of aneurysms at different locations in the anterior and posterior circulation were calculated. Kappa statistics were calculated to quantify inter- and intrareader variability in detecting aneurysms by using digital subtraction CT angiography for 100 patients.
RESULTS: Of 513 patients, 106 (20.7%) had no aneurysms, while 407 patients (79.3%) had 459 aneurysms at 3D DSA. Digital subtraction CT angiography correctly depicted 456 (99.3%) of the 459 aneurysms. By using 3D DSA as the standard of reference, the sensitivity and specificity of depicting intracranial aneurysms were 97.8% (398 of 407) and 88.7% (94 of 106), respectively, on a per-patient basis, and 96.5% (443 of 459) and 87.8% (94 of 107), respectively, on a per-aneurysm basis. Digital subtraction CT angiography had sensitivities of 91.3% (42 of 46), 94.0% (140 of 149), 98.4% (186 of 189), and 100% (75 of 75) in depicting aneurysms of less than 3 mm, between 3 mm but less than 5 mm, between 5 mm but less than 10 mm, and 10 mm or greater, respectively, and of 95.8% (276 of 288) and 97.7% (167 of 171) in depicting anterior circulation and posterior circulation aneurysms, respectively. Excellent inter- and intrareader agreement was found on a per-patient (κ=0.900 and 0.939, both P<.001) and per-aneurysm basis (κ=0.846 and 0.921, both P<.001) for the detection of intracranial aneurysms with digital subtraction CT angiography.
CONCLUSION: Digital subtraction CT angiography has a high sensitivity and specificity in depicting intracranial aneurysms with different sizes and at different locations, compared with 3D DSA. © RSNA, 2011

Entities:  

Mesh:

Year:  2011        PMID: 22143927     DOI: 10.1148/radiol.11110486

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  25 in total

1.  Subtraction CT angiography for the detection of intracranial aneurysms: A meta-analysis.

Authors:  Tian-Ying Feng; Xue-Feng Han; Rui Lang; Fei Wang; Qiong Wu
Journal:  Exp Ther Med       Date:  2016-03-15       Impact factor: 2.447

2.  Relationship between the contrast effects of raw data projection images from three-dimensional digital subtraction angiography and the optimal volume rendering parameters.

Authors:  Satoshi Takagi; Hideyuki Tokumitsu; Shigeru Sanada
Journal:  J Digit Imaging       Date:  2015-06       Impact factor: 4.056

3.  Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

Authors:  Long Jiang Zhang; Yun Fei Wang; Zhen Lu Yang; U Joseph Schoepf; Jiaqian Xu; Guang Ming Lu; Enzhong Li
Journal:  Eur Radiol       Date:  2017-03-22       Impact factor: 5.315

4.  Titanium plate artefact mimicking popliteal artery dissection on digital subtraction CT angiography.

Authors:  Timothy Woodacre; Sophie Wienand-Barnett
Journal:  BMJ Case Rep       Date:  2013-04-05

5.  Measurement science in the circulatory system.

Authors:  Casey M Jones; Sandra M Baker-Groberg; Flor A Cianchetti; Jeremy J Glynn; Laura D Healy; Wai Yan Lam; Jonathan W Nelson; Diana C Parrish; Kevin G Phillips; Devon E Scott-Drechsel; Ian J Tagge; Jaime E Zelaya; Monica T Hinds; Owen J T McCarty
Journal:  Cell Mol Bioeng       Date:  2014-03       Impact factor: 2.321

6.  Low tube voltage and low contrast material volume cerebral CT angiography.

Authors:  Song Luo; Long Jiang Zhang; Felix G Meinel; Chang Sheng Zhou; Li Qi; Andrew D McQuiston; U Joseph Schoepf; Guang Ming Lu
Journal:  Eur Radiol       Date:  2014-05-04       Impact factor: 5.315

7.  Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique.

Authors:  Guangming Ma; Yong Yu; Haifeng Duan; Yuequn Dou; Yongjun Jia; Xirong Zhang; Chuangbo Yang; Xiaoxia Chen; Dong Han; Changyi Guo; Taiping He
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

8.  Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage.

Authors:  Matteo Bonatti; Fabio Lombardo; Giulia A Zamboni; Patrizia Pernter; Roberto Pozzi Mucelli; Giampietro Bonatti
Journal:  Eur Radiol       Date:  2016-11-23       Impact factor: 5.315

9.  CT perfusion assessment of Moyamoya syndrome before and after direct revascularization (superficial temporal artery to middle cerebral artery bypass).

Authors:  Yueqin Chen; Wenjian Xu; Xiang Guo; Zhitao Shi; Zhanguo Sun; Lingyun Gao; Feng Jin; Jiehuan Wang; Weijian Chen; Yunjun Yang
Journal:  Eur Radiol       Date:  2015-05-01       Impact factor: 5.315

10.  Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography.

Authors:  Guo Zhong Chen; Song Luo; Chang Sheng Zhou; Long Jiang Zhang; Guang Ming Lu
Journal:  Eur Radiol       Date:  2017-03-13       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.