Literature DB >> 22128359

Realistic reference adult and paediatric phantom series for internal and external dosimetry.

M G Stabin1, M A Emmons, W P Segars, M J Fernald.   

Abstract

A new generation of realistic, image-based anthropomorphic phantoms has been developed based on the reference masses and organ definitions given in the International Commission on Radiological Protection Publication 89. Specific absorbed fractions for internal radiation sources have been calculated for photon and electron sources for many body organs. Values are similar to those from the previous generation of 'stylized' (mathematical equation-based) models, but some differences are seen, particularly at low particle or photon energies, due to the more realistic organ geometries, with organs generally being closer together, and with some touching and overlapping. Extension of this work, to use these phantoms in Monte Carlo radiation transport simulation codes with external radiation sources, is an important area of investigation that should be undertaken.

Mesh:

Year:  2011        PMID: 22128359      PMCID: PMC3303490          DOI: 10.1093/rpd/ncr383

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  MIRDOSE: personal computer software for internal dose assessment in nuclear medicine.

Authors:  M G Stabin
Journal:  J Nucl Med       Date:  1996-03       Impact factor: 10.057

2.  Changes in radiation dose with variations in human anatomy: moderately and severely obese adults.

Authors:  Landon D Clark; Michael G Stabin; Michael J Fernald; Aaron B Brill
Journal:  J Nucl Med       Date:  2010-05-19       Impact factor: 10.057

3.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom.

Authors:  W S Snyder; H L Fisher; M R Ford; G G Warner
Journal:  J Nucl Med       Date:  1969-08       Impact factor: 10.057

4.  Changes in radiation dose with variations in human anatomy: larger and smaller normal-stature adults.

Authors:  Patrick M Marine; Michael G Stabin; Michael J Fernald; Aaron B Brill
Journal:  J Nucl Med       Date:  2010-04-15       Impact factor: 10.057

5.  OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine.

Authors:  Michael G Stabin; Richard B Sparks; Eric Crowe
Journal:  J Nucl Med       Date:  2005-06       Impact factor: 10.057

  5 in total
  6 in total

1.  A set of 4D pediatric XCAT reference phantoms for multimodality research.

Authors:  Hannah Norris; Yakun Zhang; Jason Bond; Gregory M Sturgeon; Anum Minhas; Daniel J Tward; J T Ratnanather; M I Miller; D Frush; E Samei; W P Segars
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

2.  Automatic generation of three-dimensional dose reconstruction data for two-dimensional radiotherapy plans for historically treated patients.

Authors:  Ziyuan Wang; Marco Virgolin; Peter A N Bosman; Koen F Crama; Brian V Balgobind; Arjan Bel; Tanja Alderliesten
Journal:  J Med Imaging (Bellingham)       Date:  2020-02-03

3.  Development and validation of a GEANT4 radiation transport code for CT dosimetry.

Authors:  D E Carver; S D Kost; M J Fernald; K G Lewis; N D Fraser; D R Pickens; R R Price; M G Stabin
Journal:  Health Phys       Date:  2015-04       Impact factor: 1.316

4.  Automated modification and fusion of voxel models to construct body phantoms with heterogeneous breast tissue: Application to MRI simulations.

Authors:  Joseph V Rispoli; Steven M Wright; Craig R Malloy; Mary P McDougall
Journal:  J Biomed Graph Comput       Date:  2017-02-26

5.  Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms.

Authors:  Lukas M Carter; Chansoo Choi; Simone Krebs; Bradley Jay Beattie; Chan Hyeong Kim; Heiko Schoder; Wesley E Bolch; Adam Leon Kesner
Journal:  J Nucl Med       Date:  2021-04-16       Impact factor: 11.082

6.  Quantification of internal dosimetry in PET patients: individualized Monte Carlo vs generic phantom-based calculations.

Authors:  Sara Neira; Jacobo Guiu-Souto; Pablo Díaz-Botana; Paulino Pais; Carlos Fernández; Virginia Pubul; Álvaro Ruibal; Cristian Candela-Juan; Araceli Gago-Arias; Miguel Pombar; Juan Pardo-Montero
Journal:  Med Phys       Date:  2020-07-14       Impact factor: 4.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.