Literature DB >> 22108110

Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.

Zhi-Hua Zhang1, Hui-Yi Jin, Yan Suo, Sanjay V Patel, Robert Montés-Micó, Edward E Manche, Xun Xu.   

Abstract

PURPOSE: To examine differences in efficacy, accuracy, safety, and changes in aberrations between femtosecond and mechanical microkeratome laser in situ keratomileusis (LASIK) for myopia.
SETTING: Department of Ophthalmology, Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China.
DESIGN: Evidence-based manuscript.
METHODS: Data sources, including PubMed, Medline, EMBASE, and Cochrane Controlled Trials Register, were searched to identify potentially relevant prospective randomized controlled trials. Primary outcome measures were efficacy (uncorrected distance visual acuity ≥20/20), accuracy (±0.50 diopter mean spherical equivalent), and safety (loss of ≥2 lines of corrected distance visual acuity). Aberrations and postoperative complications were secondary outcomes.
RESULTS: Seven prospective randomized controlled trials describing a total of 577 eyes with myopia were included in this metaanalysis. At 6 months or more follow-up, no significant differences were found in the efficacy (odds ratio [OR], 1.17; 95% confidence interval [CI], 0.40 to 3.42; P=.78), accuracy (OR, 1.69; 95% CI, 0.68 to 4.20; P=.26), or safety (OR, 7.37; 95% CI, 0.37 to 147.61; P=.19). In eyes that had femtosecond LASIK, the postoperative total aberrations (mean difference -0.03 μm; 95% CI, -0.05 to -0.01; P=.002) and spherical aberrations (mean difference -0.02 μm; 95% CI, -0.03 to -0.01; P<.00001) were significantly lower.
CONCLUSIONS: According to the metaanalysis, femtosecond LASIK did not have an advantage in efficacy, accuracy, and safety measures over mechanical microkeratome LASIK in the early and midterm follow-up, although it might induce fewer aberrations.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22108110     DOI: 10.1016/j.jcrs.2011.05.043

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  21 in total

1.  Comparison of visual acuity, refractive results and complications of femtosecond laser with mechanical microkeratome in LASIK.

Authors:  Cemile Banu Cosar; Tansu Gonen; Murat Moray; Asim Bozkurt Sener
Journal:  Int J Ophthalmol       Date:  2013-06-18       Impact factor: 1.779

Review 2.  [Laser in situ keratomileusis with microkeratome or femtosecond laser].

Authors:  T Kohnen; G Steinwender
Journal:  Ophthalmologe       Date:  2017-07       Impact factor: 1.059

3.  Laser-assisted in-situ keratomileusis (LASIK) with a mechanical microkeratome compared to LASIK with a femtosecond laser for LASIK in adults with myopia or myopic astigmatism.

Authors:  Nicolás Kahuam-López; Alejandro Navas; Carlos Castillo-Salgado; Enrique O Graue-Hernandez; Aida Jimenez-Corona; Antonio Ibarra
Journal:  Cochrane Database Syst Rev       Date:  2020-04-07

4.  Comparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome.

Authors:  Jing Zhang; Shi-Sheng Zhang; Qing Yu; Jiang-Xiu Wu; Jing-Cai Lian
Journal:  Int J Ophthalmol       Date:  2014-04-18       Impact factor: 1.779

Review 5.  Wound healing after keratorefractive surgery: review of biological and optical considerations.

Authors:  Dimitri T Azar; Jin-Hong Chang; Kyu Yeon Han
Journal:  Cornea       Date:  2012-11       Impact factor: 2.651

Review 6.  Errors in Treatment of Lower-order Aberrations and Induction of Higher-order Aberrations in Laser Refractive Surgery.

Authors:  Brad E Kligman; Brandon J Baartman; William J Dupps
Journal:  Int Ophthalmol Clin       Date:  2016

7.  Myopic LASIK Outcomes: Comparison of Three Different Femtosecond Lasers and a Mechanical Microkeratome Using the Same Excimer Laser.

Authors:  Juan Gros-Otero; Isabel Rodríguez-Pérez; Miguel A Teus; Andreas Katsanos; Dimitrios G Mikropoulos; Montserrat García-González
Journal:  Ophthalmol Ther       Date:  2022-03-09

8.  One-year eye-to-eye comparison of wavefront-guided versus wavefront-optimized laser in situ keratomileusis in hyperopes.

Authors:  Christopher S Sáles; Edward E Manche
Journal:  Clin Ophthalmol       Date:  2014-11-12

9.  Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2) and two different femtosecond lasers (FS60 and FS200).

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Clin Ophthalmol       Date:  2013-04-03

10.  Corneal backscatter analysis by in vivo confocal microscopy: fellow eye comparison of small incision lenticule extraction and femtosecond laser-assisted LASIK.

Authors:  Alper Agca; Engin Bilge Ozgurhan; Yusuf Yildirim; Kadir Ilker Cankaya; Nimet Burcu Guleryuz; Zeynep Alkin; Abdullah Ozkaya; Ahmet Demirok; Omer Faruk Yilmaz
Journal:  J Ophthalmol       Date:  2014-03-05       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.