Literature DB >> 23826532

Comparison of visual acuity, refractive results and complications of femtosecond laser with mechanical microkeratome in LASIK.

Cemile Banu Cosar1, Tansu Gonen, Murat Moray, Asim Bozkurt Sener.   

Abstract

AIM: To compare the outcomes of laser in situ keratomileusis (LASIK) performed with a femtosecond laser (Femtec, Technolas Perfect Vision GmbH, Germany) versus a mechanical microkeratome (Hansatome, Bausch and Lomb, USA) for the correction of myopia and astigmatism.
METHODS: In this retrospective study, patients who had undergone LASIK using the 80-kHz Femtec femtosecond laser were compared to age- and refraction-matched patients in whom the Hansatome microkeratome was used. Refractive and visual results 1 month and 3 months postoperatively, and complication rates were compared between the two groups.
RESULTS: A total of 280 eyes were analyzed (140 in each group). At 3 months postoperatively in the Femtec vs Hansatome group, spherical equivalent refraction was within ±1.00D of emmetropia in 140 vs 138 eyes (P=0.498), the cylinder was within ±0.50D in 137 vs 139 eyes (P=0.622), and the UDVA was 20/20 or better in 136 vs 137 eyes (P=0.724), respectively. There was no statistically significant difference in the complication rates between the two groups (P=0.099).
CONCLUSION: LASIK performed both with Femtec femtosecond laser and Hansatome microkeratome achieved satisfactory refractive and visual results at 3 months postoperatively, without significant differences in efficacy, safety, and complication rates between the two procedures.

Entities:  

Keywords:  Femtec; Hansatome; femtosecond laser; laser in situ keratomileusis; microkeratome

Year:  2013        PMID: 23826532      PMCID: PMC3693019          DOI: 10.3980/j.issn.2222-3959.2013.03.18

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  14 in total

1.  Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis.

Authors:  Guy M Kezirian; Karl G Stonecipher
Journal:  J Cataract Refract Surg       Date:  2004-04       Impact factor: 3.351

2.  Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.

Authors:  Zhi-Hua Zhang; Hui-Yi Jin; Yan Suo; Sanjay V Patel; Robert Montés-Micó; Edward E Manche; Xun Xu
Journal:  J Cataract Refract Surg       Date:  2011-12       Impact factor: 3.351

3.  Overview of commercially available femtosecond lasers in refractive surgery.

Authors:  Holger Lubatschowski
Journal:  J Refract Surg       Date:  2008-01       Impact factor: 3.573

Review 4.  Femtosecond lasers in ophthalmology.

Authors:  H Kaz Soong; João Baptista Malta
Journal:  Am J Ophthalmol       Date:  2008-10-18       Impact factor: 5.258

5.  Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis: prospective contralateral eye study.

Authors:  Daniel S Durrie; Guy M Kezirian
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

6.  Dry eye associated with laser in situ keratomileusis: Mechanical microkeratome versus femtosecond laser.

Authors:  Marcella Q Salomão; Renato Ambrósio; Steven E Wilson
Journal:  J Cataract Refract Surg       Date:  2009-10       Impact factor: 3.351

7.  Rainbow glare as an optical side effect of IntraLASIK.

Authors:  Ronald R Krueger; Ivey L Thornton; Meng Xu; Zsolt Bor; Thomas J T P van den Berg
Journal:  Ophthalmology       Date:  2007-12-27       Impact factor: 12.079

8.  Incidence of diffuse lamellar keratitis after laser in situ keratomileusis associated with the IntraLase 15 kHz femtosecond laser and Moria M2 microkeratome.

Authors:  Raquel Gil-Cazorla; Miguel A Teus; Laura de Benito-Llopis; Irene Fuentes
Journal:  J Cataract Refract Surg       Date:  2008-01       Impact factor: 3.351

9.  Transient light sensitivity after femtosecond laser flap creation: clinical findings and management.

Authors:  Karl G Stonecipher; Jon G Dishler; Teresa S Ignacio; Perry S Binder
Journal:  J Cataract Refract Surg       Date:  2006-01       Impact factor: 3.351

10.  Anterior segment OCT analysis of thin IntraLase femtosecond flaps.

Authors:  Jason E Stahl; Daniel S Durrie; Frank J Schwendeman; Allen J Boghossian
Journal:  J Refract Surg       Date:  2007-06       Impact factor: 3.573

View more
  6 in total

1.  Laser-assisted in-situ keratomileusis (LASIK) with a mechanical microkeratome compared to LASIK with a femtosecond laser for LASIK in adults with myopia or myopic astigmatism.

Authors:  Nicolás Kahuam-López; Alejandro Navas; Carlos Castillo-Salgado; Enrique O Graue-Hernandez; Aida Jimenez-Corona; Antonio Ibarra
Journal:  Cochrane Database Syst Rev       Date:  2020-04-07

2.  Influence of transient intraocular pressure elevation during laser in situ keratomileusis on rabbit retina thickness.

Authors:  Hai-Xia Zhao; Hui Liu; Chun-Mei Niu; Wen-Ying Guan
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

3.  Comparison of the femtosecond laser and mechanical microkeratome for flap cutting in LASIK.

Authors:  Li-Kun Xia; Jie Yu; Guang-Rui Chai; Dang Wang; Yang Li
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

4.  Visumax femtolasik versus Moria M2 microkeratome in mild to moderate myopia: efficacy, safety, predictability, aberrometric changes and flap thickness predictability.

Authors:  Magda A Torky; Yousif A Al Zafiri; Abeer M Khattab; Rania K Farag; Eman A Awad
Journal:  BMC Ophthalmol       Date:  2017-07-17       Impact factor: 2.209

5.  Treatment of High Astigmatism with WaveLight Allegretto Eye-Q Excimer Laser Platform.

Authors:  Alma Biscevic; Maja Bohac; Melisa Ahmedbegovic Pjano; Senad Grisevic; Sudi Patel; Ajla Pidro
Journal:  Acta Inform Med       Date:  2019-09

6.  Refractive outcomes of an advanced aspherically optimized profile for myopia corrections by LASIK: a retrospective comparison with the standard aspherically optimized profile.

Authors:  Bertram Meyer; Georg Sluyterman van Langeweyde; Matthias Wottke
Journal:  Clin Ophthalmol       Date:  2015-02-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.