Literature DB >> 22106352

Feasibility and accuracy of dual-source dual-energy CT for noninvasive determination of hepatic iron accumulation.

Eugene Joe1, Se Hyung Kim, Kyoung Bun Lee, Ja-June Jang, Jae Young Lee, Jeong Min Lee, Joon Koo Han, Byung Ihn Choi.   

Abstract

PURPOSE: To retrospectively assess feasibility of dual-source dual-energy (DSDE) computed tomography (CT) for evaluation of hepatic iron accumulation in a liver phantom and liver transplantation candidates and to compare its accuracy with that of 3-T magnetic resonance (MR) imaging.
MATERIALS AND METHODS: This study was approved by the institutional review board; informed consent was waived. A liver agar phantom containing six tubes of iron (concentrations, 100-5000 mg of iron per 100 mL of solution) was scanned at 80 and 140 kVp with both DSDE mode and single-source dual-energy (SSDE) CT with sequential scanning mode. Difference of averaged attenuation between 80 and 140 kVp at CT (ΔH) was measured and correlated with iron concentration. Thirty-two liver transplant recipients and 55 donors who underwent DSDE CT at 80 and 140 kVp were included. Twenty-three underwent 3-T liver MR with dual-echo in-phase and opposed-phase T1-weighted and spin-echo T2-weighted imaging. Hepatic ΔH was measured at CT. On T1- and T2-weighted MR images, iron indexes were calculated. Degree of iron accumulation and macrosteatosis were determined at histologic examination (reference). Diagnostic performance of ΔH at CT and iron indexes at MR for diagnosing clinically important iron accumulation was evaluated (receiver operating characteristic [ROC] analysis).
RESULTS: For phantom study, ΔH obtained from both DSDE mode and SSDE CT with sequential scanning mode was correlated with iron concentration (correlation coefficient, 1.00 and 0.943, respectively; P = .173). ΔH (13.53) in 10 patients with clinically important (≥ 10%) iron accumulation was significantly higher than that (7.39) in 77 patients with normal or mild iron deposition (P < .001). ΔH was significantly correlated with degree of iron accumulation (correlation coefficient, 0.430; P < .001) but not with degree of hepatic macrosteatosis (P = .216). Area under the ROC curve for diagnosing clinically important iron accumulation was 0.881 and 0.897 with CT and MR, respectively (P = .851).
CONCLUSION: DSDE CT is accurate for diagnosing clinically important hepatic iron accumulation without confounding influence of hepatic steatosis, with diagnostic performance on par with MR. © RSNA, 2011.

Entities:  

Mesh:

Year:  2011        PMID: 22106352     DOI: 10.1148/radiol.11110060

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  24 in total

1.  Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.

Authors:  Julian L Wichmann; Andrew D Hardie; U Joseph Schoepf; Lloyd M Felmly; Jonathan D Perry; Akos Varga-Szemes; Stefanie Mangold; Damiano Caruso; Christian Canstein; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

2.  Dual-energy CT for liver iron quantification in patients with haematological disorders.

Authors:  Sebastian Werner; Bernhard Krauss; Ulrike Haberland; Malte Bongers; Uwe Starke; Tamam Bakchoul; Sigrid Enkel; Konstantin Nikolaou; Marius Horger
Journal:  Eur Radiol       Date:  2018-11-07       Impact factor: 5.315

Review 3.  Recent Advances in CT and MR Imaging for Evaluation of Hepatocellular Carcinoma.

Authors:  Jeong Min Lee; Jeong-Hee Yoon; Ijin Joo; Hyun Sik Woo
Journal:  Liver Cancer       Date:  2012-06       Impact factor: 11.740

4.  Virtual iron concentration imaging based on dual-energy CT for noninvasive quantification and grading of liver iron content: An iron overload rabbit model study.

Authors:  Xian Fu Luo; Yi Yang; Jing Yan; Xue Qian Xie; Huan Zhang; Wei Min Chai; Li Wang; Bernhard Schmidt; Fu Hua Yan
Journal:  Eur Radiol       Date:  2015-03-15       Impact factor: 5.315

5.  Noninvasive estimation of local speed of sound by pulse-echo ultrasound in a rat model of nonalcoholic fatty liver.

Authors:  Arsenii V Telichko; Rehman Ali; Thurston Brevett; Huaijun Wang; Jose G Vilches-Moure; Sukumar U Kumar; Ramasamy Paulmurugan; Jeremy J Dahl
Journal:  Phys Med Biol       Date:  2022-01-17       Impact factor: 3.609

Review 6.  Quantitative dual-energy CT techniques in the abdomen.

Authors:  Giuseppe V Toia; Achille Mileto; Carolyn L Wang; Dushyant V Sahani
Journal:  Abdom Radiol (NY)       Date:  2021-09-01

7.  Comparison of MR Imaging and Dual-Energy CT for the Evaluation of Cartilage Invasion by Laryngeal and Hypopharyngeal Squamous Cell Carcinoma.

Authors:  H Kuno; K Sakamaki; S Fujii; K Sekiya; K Otani; R Hayashi; T Yamanaka; O Sakai; M Kusumoto
Journal:  AJNR Am J Neuroradiol       Date:  2018-01-25       Impact factor: 3.825

Review 8.  Dual-energy CT in diffuse liver disease: is there a role?

Authors:  Khaled Y Elbanna; Bahar Mansoori; Achille Mileto; Patrik Rogalla; Luís S Guimarães
Journal:  Abdom Radiol (NY)       Date:  2020-08-08

9.  The influence of liver fat deposition on the quantification of the liver-iron fraction using fast-kilovolt-peak switching dual-energy CT imaging and material decomposition technique: an in vitro experimental study.

Authors:  Tingting Xie; Yongbin Li; Guanyong He; Zhen Zhang; Qiao Shi; Guanxun Cheng
Journal:  Quant Imaging Med Surg       Date:  2019-04

10.  Investigating Dual-Energy CT Post-Contrast Phases for Liver Iron Quantification: A Preliminary Study.

Authors:  Luca Basso; Dario Baldi; Lorenzo Mannelli; Carlo Cavaliere; Marco Salvatore; Valentina Brancato
Journal:  Dose Response       Date:  2021-06-01       Impact factor: 2.658

View more