Literature DB >> 22096437

A randomized, prospective study comparing intertrochanteric hip fracture fixation with the dynamic hip screw and the dynamic helical hip system in a community practice.

Daniel C Fitzpatrick1, Daniel V Sheerin, Brian R Wolf, Thomas K Wuest.   

Abstract

OBJECTIVE: To evaluate the clinical performance of the Dynamic Helical Hip System (DHHS) spiral blade relative to the Dynamic Hip Screw (DHS) lag screw.
DESIGN: Randomized prospective study.
SETTING: One level-2 trauma center and one level-3 trauma center. PATIENTS: Fifty-one consecutive patients were recruited into the trial. Inclusion criteria included patients over 50 years of age with AO/OTA 31A1 or 31A2 fracture. INTERVENTION: Surgeries were performed by one of 15 participating community orthopaedic surgeons. The patients were randomized to either a DHHS or DHS implant. Follow-up occurred at two weeks and six weeks and then at six-week intervals until healing occurred. MAIN OUTCOME MEASURES: Primary outcome variables included sliding of die implant on the final AP radiographs, failure by cut-out and implant failure.
RESULTS: There were 24 patients in the DHS group and 27 in the DHHS group. There was no difference in age, gender, ASA score, fracture classification or in the quality of reduction measured on the immediate postoperative radiographs (p=0.28) between the two groups. The tip apex distance was 18.7 mm in the DHHS group and 18.5 mm in the DHS group (p=0.40). The DHHS group had average blade sliding of 7.4 mm while the DHS group had an average lag-screw sliding of 7.7 (p=0.45). The DHHS group had two failures by central protrusion of the blade through the femoral head without significant varus collapse or superior migration. One was revised to a DHS and healed, the other was revised to a proximal femoral locking plate, which also failed and eventually required revision to a total hip arthroplasty. Investigation of the implants post failure showed evidence of binding of the blade shaft in the barrel as a mechanism of failure in both cases. No DHS implants cut out in this series, although one patient was revised to a total hip arthroplasty for symptomatic segmental osteonecrosis.
CONCLUSION: Both implants performed well in a majority of cases. The higher incidence of failure in the DHHS group is concerning, despite the low numbers. The mechanism of failure of the DHHS implant left adequate bone stock for attempts at revision fixation.

Entities:  

Mesh:

Year:  2011        PMID: 22096437      PMCID: PMC3215131     

Source DB:  PubMed          Journal:  Iowa Orthop J        ISSN: 1541-5457


  22 in total

1.  Hip protectors--a breakthrough in fracture prevention.

Authors:  L Rubenstein
Journal:  N Engl J Med       Date:  2000-11-23       Impact factor: 91.245

2.  A ten-year analysis of intertrochanteric fractures of the femur.

Authors:  M CLEVELAND; D M BOSWORTH; F R THOMPSON; H J WILSON; T ISHIZUKA
Journal:  J Bone Joint Surg Am       Date:  1959-12       Impact factor: 5.284

3.  Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw.

Authors:  R C Haynes; R G Pöll; A W Miles; R B Weston
Journal:  Injury       Date:  1997 Jun-Jul       Impact factor: 2.586

4.  Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification.

Authors: 
Journal:  J Orthop Trauma       Date:  1996       Impact factor: 2.512

5.  1999 National Hospital Discharge Survey: annual summary with detailed diagnosis and procedure data.

Authors:  J R Popovic
Journal:  Vital Health Stat 13       Date:  2001-09

6.  Determining factors for the mortality following hip fractures.

Authors:  J S Jensen
Journal:  Injury       Date:  1984-05       Impact factor: 2.586

7.  Collapse of intertrochanteric hip fractures fixed with sliding screws.

Authors:  J A Bendo; L S Weiner; E Strauss; E Yang
Journal:  Orthop Rev       Date:  1994-08

8.  Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients.

Authors:  D C Hardy; P Y Descamps; P Krallis; L Fabeck; P Smets; C L Bertens; P E Delince
Journal:  J Bone Joint Surg Am       Date:  1998-05       Impact factor: 5.284

9.  Sliding characteristics of compression hip screws in the intertrochanteric fracture: a clinical study.

Authors:  F Yoshimine; L L Latta; E L Milne
Journal:  J Orthop Trauma       Date:  1993       Impact factor: 2.512

10.  Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation.

Authors:  Markus Windolf; Volker Braunstein; Christof Dutoit; Karsten Schwieger
Journal:  Clin Biomech (Bristol, Avon)       Date:  2008-10-31       Impact factor: 2.063

View more
  7 in total

1.  Is helical blade superior to screw design in terms of cut-out rate for elderly trochanteric fractures? A meta-analysis of randomized controlled trials.

Authors:  Xiao Huang; Frankie Leung; Ming Liu; Long Chen; Zhao Xu; Zhou Xiang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-02-21

Review 2.  Intertrochanteric fractures: a review of fixation methods.

Authors:  Senthil Nathan Sambandam; Jayadev Chandrasekharan; Varatharaj Mounasamy; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-30

Review 3.  Surgical interventions for treating extracapsular hip fractures in older adults: a network meta-analysis.

Authors:  Sharon R Lewis; Richard Macey; Joseph Lewis; Jamie Stokes; James R Gill; Jonathan A Cook; William Gp Eardley; Martyn J Parker; Xavier L Griffin
Journal:  Cochrane Database Syst Rev       Date:  2022-02-10

4.  Outcome of the dynamic helical hip screw system for intertrochanteric hip fractures in the elderly patients.

Authors:  Natasha T O'Malley; Andrew-Paul Deeb; Karilee W Bingham; Stephen L Kates
Journal:  Geriatr Orthop Surg Rehabil       Date:  2012-06

5.  Disengagement and intrapelvic migration of a dynamic helical hip screw.

Authors:  Segen Aklilu; David P Barei; Felix S Chew
Journal:  Radiol Case Rep       Date:  2018-12-01

6.  Migration Measurement of Pins in Postoperative Recovery of the Proximal Femur Fractures Based on 3D Point Cloud Matching.

Authors:  Kaifeng Liu; Kouki Nagamune; Keisuke Oe; Ryosuke Kuroda; Takahiro Niikura
Journal:  Medicina (Kaunas)       Date:  2021-04-22       Impact factor: 2.430

7.  Radiological and functional outcome in unstable, osteoporotic trochanteric fractures stabilized with dynamic helical hip system.

Authors:  Ram Chander Siwach; Rajesh Rohilla; Roop Singh; Rohit Singla; Sukhbir Singh Sangwan; Paritosh Gogna
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-07-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.